Binli Liu

Binli Liu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YJYingjie Jia
Yingjie Jia
FXFei Xiao
Fei Xiao
YDYaoqiang Duan
Yaoqiang Duan
YLYifei Luo
Yifei Luo
BLBinli Liu
Binli Liu
YHYongle Huang
Yongle Huang
The behavior of the insulated gate bipolar transistor (IGBT) module results in the electric field, temperature field, and stress field, and there are strong coupling effects among its electrical, temperature, and mechanical characteristics. Meanwhile, the packaging failure of IGBT module is also the interaction results of multi-physical fields coupling. In this article, a multi-physical fields transient modeling method based on PSpice and COMSOL is proposed. This method synthesizes the advantages of the physical model and the finite-element model. According to the time constants of different physical fields, continuous simulation analysis is carried out on different timescales. Through flexible multispeed simulation strategy, the dynamic characteristics of IGBT devices at different timescales can be accurately characterized. First, the electric-thermal-mechanical coupling mechanism of IGBT is described. Then, the electrical model and thermomechanical coupling model of IGBT are constructed in PSpice and COMSOL, respectively, and the multi-physical fields simulation in multi-timescale is realized through the control file of MATLAB script. The proposed modeling approach is verified by a short-circuit test of Starpower 1200-V/50-A IGBT module. Finally, an example of multi-time-scale simulation analysis under short-circuit condition is given, and the reasons for module failure under multi-field coupling effect are studied.

22 October 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYifei Luo
Yifei Luo
FXFei Xiao
Fei Xiao
BLBinli Liu
Binli Liu
YHYongle Huang
Yongle Huang

18 December 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
BLBinli Liu
Binli Liu
FXFei Xiao
Fei Xiao
YLYifei Luo
Yifei Luo
YHYongle Huang
Yongle Huang
YXYouxing Xiong
Youxing Xiong

21 June 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
THTongyao Han
Tongyao Han
YLYifei Luo
Yifei Luo
BLBinli Liu
Binli Liu
ZSZenan Shi
Zenan Shi
HSHaolan Shen
Haolan Shen
As the power density of power modules increases, the cross-heating effects in multichip modules become severe, which intensifies the local overheating stress. To accurately predict the dynamic thermal characteristics of the multichip modules, this paper establishes the mathematical relationship between the resistance-capacitance (RC) parameters and the thermal diffusion angle to obtain accurate RC parameters. The decoupling of the self-heating and cross-heating effects is realized according to the dynamic power flow in the RC thermal network, reducing the transient thermal impedance matrix to the steady-state thermal resistance matrix. In this way, the 3-D cross-heating effect on the junction temperature is characterized by the 1-D RC thermal network. Then, an efficient junction temperature simulation model based on the reduced-order decoupling method is proposed. This article also identifies the variation law of RC parameters with boundary conditions. Compared with existing models that need transient information, the model parameter extraction process requires only the steady-state information of the finite element method (FEM) and fewer RC parameters, which improves the parameter extraction efficiency by more than 87 times. In addition, compared with the FEM model, the transient junction temperature prediction efficiency is improved by more than 994 times. Finally, based on a 1200V/50A half-bridge module, an electrothermal coupling model is constructed and applied to a three-phase two-stage inverter circuit. The results verify the accuracy and effectiveness of the proposed model, demonstrating that the junction temperature error between the proposed model and the experimental result is less than 5%.

19 June 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YDYaoqiang Duan
Yaoqiang Duan
FXFei Xiao
Fei Xiao
YJYingjie Jia
Yingjie Jia
YLYifei Luo
Yifei Luo
BLBinli Liu
Binli Liu

20 June 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HYHao Yuan
Hao Yuan
BLBinli Liu
Binli Liu
YLYifei Luo
Yifei Luo
THTongyao Han
Tongyao Han
Yu ZhangYu Zhang
Yu Zhang
ZSZenan Shi
Zenan Shi
The junction temperature ( T j ) obtained by the V ce(on) -based junction temperature estimation model under high current, the accuracy of which depends on the output characteristics curve of the IGBT modules. However, there is a significant increase in the conduction voltage drop V ce(on) throughout the fatigue degradation process. As a result, substantial errors occur in the T j obtained through the traditional V ce(on) -based junction temperature estimation model. Under high current, lifting-off of bonding wires emerges as the primary fatigue mode. In this article, therefore, the crack propagation behavior at the bonding nodes is thoroughly analyzed based on the bonding wire lift-off fatigue mechanism, and an equivalent resistance degradation model is established. Ultimately, a V ce(on) -based T j estimation model that considers the degradation is selected before correcting the output characteristic curve of the fatigue-degraded modules. This model effectively considers the offset in the curve caused by the degradation, thus realizing online T j monitoring after long-term fatigue. An experimental system has been set up, demonstrating that the error between the T j obtained from the corrected model and the actual T j does not exceed 2%. The method proposed in this paper can diminish the error by more than 30% compared to the uncorrected model.