Tongyao Han

Dr. Tongyao Han


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
THTongyao Han
Tongyao Han
YLYifei Luo
Yifei Luo
BLBinli Liu
Binli Liu
ZSZenan Shi
Zenan Shi
HSHaolan Shen
Haolan Shen
As the power density of power modules increases, the cross-heating effects in multichip modules become severe, which intensifies the local overheating stress. To accurately predict the dynamic thermal characteristics of the multichip modules, this paper establishes the mathematical relationship between the resistance-capacitance (RC) parameters and the thermal diffusion angle to obtain accurate RC parameters. The decoupling of the self-heating and cross-heating effects is realized according to the dynamic power flow in the RC thermal network, reducing the transient thermal impedance matrix to the steady-state thermal resistance matrix. In this way, the 3-D cross-heating effect on the junction temperature is characterized by the 1-D RC thermal network. Then, an efficient junction temperature simulation model based on the reduced-order decoupling method is proposed. This article also identifies the variation law of RC parameters with boundary conditions. Compared with existing models that need transient information, the model parameter extraction process requires only the steady-state information of the finite element method (FEM) and fewer RC parameters, which improves the parameter extraction efficiency by more than 87 times. In addition, compared with the FEM model, the transient junction temperature prediction efficiency is improved by more than 994 times. Finally, based on a 1200V/50A half-bridge module, an electrothermal coupling model is constructed and applied to a three-phase two-stage inverter circuit. The results verify the accuracy and effectiveness of the proposed model, demonstrating that the junction temperature error between the proposed model and the experimental result is less than 5%.

9 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
THTongyao Han
Tongyao Han
YLYifei Luo
Yifei Luo
BLBinli Liu
Binli Liu
XMXiao Ma
Xiao Ma
FXFeng Xie
Feng Xie
Based on extremely uneven temperature distribution along the insulated gate bipolar transistor (IGBT) chip vertical path during switching transients, a short-duration transient microsecond-scale prediction model applicable to multi-timescale simulation is presented in this paper. Traditional thermal models often take the chip active area as a uniform heat source to obtain a victual junction temperature (Tvj). In this paper, a discrete distributed heat source model combined with a thermal network model based on the sublayer division strategy is proposed to achieve an accurate temperature distribution description along the chip vertical path. Taking a 1700 V/3600 A IGBT module as an example, the proposed model can evaluate the short-duration transient temperature distribution along the chip vertical path and the error is less than 2 °C compared with the finite element model. Meanwhile, the model is applied to a single short-duration transient timescale and multi-timescale systems separately, and the simulation speed is increased by more than 80 times and 297 times, which verifies its validity and accuracy.

20 June 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HYHao Yuan
Hao Yuan
BLBinli Liu
Binli Liu
YLYifei Luo
Yifei Luo
THTongyao Han
Tongyao Han
Yu ZhangYu Zhang
Yu Zhang
ZSZenan Shi
Zenan Shi
The junction temperature ( T j ) obtained by the V ce(on) -based junction temperature estimation model under high current, the accuracy of which depends on the output characteristics curve of the IGBT modules. However, there is a significant increase in the conduction voltage drop V ce(on) throughout the fatigue degradation process. As a result, substantial errors occur in the T j obtained through the traditional V ce(on) -based junction temperature estimation model. Under high current, lifting-off of bonding wires emerges as the primary fatigue mode. In this article, therefore, the crack propagation behavior at the bonding nodes is thoroughly analyzed based on the bonding wire lift-off fatigue mechanism, and an equivalent resistance degradation model is established. Ultimately, a V ce(on) -based T j estimation model that considers the degradation is selected before correcting the output characteristic curve of the fatigue-degraded modules. This model effectively considers the offset in the curve caused by the degradation, thus realizing online T j monitoring after long-term fatigue. An experimental system has been set up, demonstrating that the error between the T j obtained from the corrected model and the actual T j does not exceed 2%. The method proposed in this paper can diminish the error by more than 30% compared to the uncorrected model.

3 April 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
THTongyao Han
Tongyao Han
YLYifei Luo
Yifei Luo
BLBinli Liu
Binli Liu
HYHao Yuan
Hao Yuan
ZSZenan Shi
Zenan Shi
Insulated gate bipolar transistors (IGBTs) power module experience significant thermal stress during short-time overload conditions, and their electro-thermal characteristics exhibit strong nonlinearities. As a result, the two-dimensional safe operating area (SOA) provided in the datasheet is unable to meet the need of device reliability assessments. In this paper, we propose a quantitative assessment method based on the thermal balance principle to define the SOA for IGBTs and assess its degradation. A three-dimensional SOA that incorporates voltage, current, and junction temperature is established to prevent IGBT from thermal failures. The proposed SOA indicates that IGBT can operate safely at more than twice the rated current, and the junction temperature can exceed 448.15K(175° C) without thermal failures. This work provides theoretical support for IGBT application design and reliability assessment. According to the physical mechanisms associated with thermal failures of IGBT power module, a criterion to characterize the thermal instability of devices is established. Further, the net heat flux analysis model that integrates semiconductor physics with heat conduction theory is established, enabling the formulation of the three-dimensional SOA of IGBT. Moreover, the effects of the degradation of electro-thermal characteristics on the SOA throughout the long-term operation of the device is considered. In addition, an electro-thermal coupling model that simulates the electro-thermal characteristics of the device is established. The results from both simulation and experiment demonstrate that the established SOA and its degradation effectively predict the reliability of the IGBT under short-time overload conditions.

17 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HSHaolan Shen
Haolan Shen
XTXin Tang
Xin Tang
YLYifei Luo
Yifei Luo
ZSZenan Shi
Zenan Shi
THTongyao Han
Tongyao Han
The dual active bridge (DAB) converter is a popular DC–DC converter topology for high-power applications. An open-circuit fault (OCF) in DAB converter can produce a DC bias in its transformer currents, which can saturate the transformer, resulting in significant power losses and power quality deterioration. In this paper, a refined modeling and an online OCF diagnosis method are proposed for OCF in DAB converters. Firstly, the causes of voltage and current waveform distortion caused by OCF are analyzed in detail. The reasons for differences in transformer voltage and current waveforms due to different OCF positions are studied. The importance of critical parameters such as the magnetizing inductance of transformers and parasitic capacitance of power switches to analysis of circuit operation characteristics under OCF conditions is clarified. Based on this theoretical research, a refined DAB converter modeling incorporating critical parameters is proposed. In contrast to current models, this proposed model offers improved accuracy in depicting variations of primary-side electrical parameters under OCF conditions. Additionally, an OCF diagnosis method is proposed. This method utilizes the cycle-average value of the transformer primary-side current for OCF detection and localization. Unlike prior methods, the proposed method does not necessitate supplementary hardware sensing conditions, nor does it require the converter to operate in a specific switching state. Finally, the online deployment of OCF diagnosis method based on FPGA is completed. Experimental results verify that the proposed model effectively simulates variations in the primary-side and secondary-side currents of the transformer, as well as the magnetizing current, under OCF conditions. As a fault feature, the mean absolute error (MAE) of the primary-side current is within 0.5A and the period average error is within 0.2%. Moreover, the online OCF diagnosis method enables OCF detection within 1 switching cycle and OCF localization within 6 switching cycles.