1 January 2024 in IEEE Transactions on Instrumentation and Measurement
The accuracy of data-driven open-circuit fault diagnosis methods is affected by varying operating conditions. This issue is often ignored. In this paper, an improved convolutional neural network (CNN) and a sample amplification method are proposed to eliminate the influence of varying operating conditions on the online open-circuit fault (OCF) diagnosis for neutral point clamped (NPC) inverter. Firstly, 73 types of open-circuit fault sample collection can be greatly reduced to 14 by following the sample amplification method. The signals of any phase can be generated by a single fundamental period signal. This provides a significant savings in sample collection time. Secondly, the spatial attention mechanism (SAM) is added after the first convolutional layer of the CNN model. The feature extraction capability of the model is enhanced for time-domain waveform scaling under variable operating conditions. Simultaneously, the last full connection (FC) layer of the CNN model is retained and the other FC layers are substituted with a global maximum pooling (GMP) layer. This has the advantage of reducing the number of network parameters and further conserving the effective feature information. In conclusion, the experimental results show that the sample amplification method and the improved CNN model for online fault diagnosis under varying operating conditions exceed 99% accuracy. The SAMCNN-GMP is more effective and stable than the CNN model.
21 June 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
As the power density of power modules increases, the cross-heating effects in multichip modules become severe, which intensifies the local overheating stress. To accurately predict the dynamic thermal characteristics of the multichip modules, this paper establishes the mathematical relationship between the resistance-capacitance (RC) parameters and the thermal diffusion angle to obtain accurate RC parameters. The decoupling of the self-heating and cross-heating effects is realized according to the dynamic power flow in the RC thermal network, reducing the transient thermal impedance matrix to the steady-state thermal resistance matrix. In this way, the 3-D cross-heating effect on the junction temperature is characterized by the 1-D RC thermal network. Then, an efficient junction temperature simulation model based on the reduced-order decoupling method is proposed. This article also identifies the variation law of RC parameters with boundary conditions. Compared with existing models that need transient information, the model parameter extraction process requires only the steady-state information of the finite element method (FEM) and fewer RC parameters, which improves the parameter extraction efficiency by more than 87 times. In addition, compared with the FEM model, the transient junction temperature prediction efficiency is improved by more than 994 times. Finally, based on a 1200V/50A half-bridge module, an electrothermal coupling model is constructed and applied to a three-phase two-stage inverter circuit. The results verify the accuracy and effectiveness of the proposed model, demonstrating that the junction temperature error between the proposed model and the experimental result is less than 5%.
17 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The dual active bridge (DAB) converter is a popular DC–DC converter topology for high-power applications. An open-circuit fault (OCF) in DAB converter can produce a DC bias in its transformer currents, which can saturate the transformer, resulting in significant power losses and power quality deterioration. In this paper, a refined modeling and an online OCF diagnosis method are proposed for OCF in DAB converters. Firstly, the causes of voltage and current waveform distortion caused by OCF are analyzed in detail. The reasons for differences in transformer voltage and current waveforms due to different OCF positions are studied. The importance of critical parameters such as the magnetizing inductance of transformers and parasitic capacitance of power switches to analysis of circuit operation characteristics under OCF conditions is clarified. Based on this theoretical research, a refined DAB converter modeling incorporating critical parameters is proposed. In contrast to current models, this proposed model offers improved accuracy in depicting variations of primary-side electrical parameters under OCF conditions. Additionally, an OCF diagnosis method is proposed. This method utilizes the cycle-average value of the transformer primary-side current for OCF detection and localization. Unlike prior methods, the proposed method does not necessitate supplementary hardware sensing conditions, nor does it require the converter to operate in a specific switching state. Finally, the online deployment of OCF diagnosis method based on FPGA is completed. Experimental results verify that the proposed model effectively simulates variations in the primary-side and secondary-side currents of the transformer, as well as the magnetizing current, under OCF conditions. As a fault feature, the mean absolute error (MAE) of the primary-side current is within 0.5A and the period average error is within 0.2%. Moreover, the online OCF diagnosis method enables OCF detection within 1 switching cycle and OCF localization within 6 switching cycles.