Since the late 1990s, there has been a burst of research on robotic devices for poststroke rehabilitation. Robot-mediated therapy produced improvements on recovery of motor capacity; however, so far, the use of robots has not shown qualitative benefit over classical therapist-led training sessions, performed on the same quantity of movements. Multidegree-of-freedom robots, like the modern upper-limb exoskeletons, enable a distributed interaction on the whole assisted limb and can exploit a large amount of sensory feedback data, potentially providing new capabilities within standard rehabilitation sessions. Surprisingly, most publications in the field of exoskeletons focused only on mechatronic design of the devices, while little details were given to the control aspects. On the contrary, we believe a paramount aspect for robots potentiality lies on the control side. Therefore, the aim of this review is to provide a taxonomy of currently available control strategies for exoskeletons for neurorehabilitation, in order to formulate appropriate questions toward the development of innovative and improved control strategies.
1 December 2014 in Frontiers in Human Neuroscience
Upper-limb impairment after stroke is caused by weakness, loss of individual joint control, spasticity and abnormal synergies. Upper limb movement frequently involves abnormal, stereotyped and fixed synergies, likely related to the increased use of subcortical networks following the stroke. The flexible coordination of the shoulder and elbow joints is also disrupted. New methods for motor learning, based on the stimulation of activity-dependent neural plasticity have been developed. These include robots that can adaptively assist active movements and generate many movement repetitions. However, most of these robots only control the movement of the hand in space. The aim of the present text is to analyse the potential of robotic exoskeletons to specifically rehabilitate joint motion and particularly inter-joint coordination. Firstly, a review of studies on upper-limb coordination in stroke patients is presented and the potential for recovery of coordination is examined. Secondly, issues relating to the mechanical design of exoskeletons and the transmission of constraints between the robotic and human limbs are discussed. The third section considers the development of different methods to control exoskeletons: existing rehabilitation devices and approaches to the control and rehabilitation of joint coordinations are then reviewed, along with preliminary clinical results available. Finally, perspectives and future strategies for the design of control mechanisms for rehabilitation exoskeletons are discussed.
Despite promising results in the rehabilitation field, it remains unclear whether upper limb robotic wearables, e.g., for people with physical impairments resulting from neurodegenerative disease, can be made portable and suitable for everyday use. We present a lightweight, fully portable, textile-based, soft inflatable wearable robot for shoulder elevation assistance that provides dynamic active support to the upper limbs. The technology is mechanically transparent when unpowered, can quantitatively assess free movement of the user, and adds only 150 grams of weight to each upper limb. In 10 individuals with amyotrophic lateral sclerosis (ALS) with different degrees of neuromuscular impairment, we demonstrated immediate improvement in the active range of motion and compensation for continuing physical deterioration in two individuals with ALS over 6 months. Along with improvements in movement, we show that this robotic wearable can improve functional activity without any training, restoring performance of basic activities of daily living. In addition, a reduction in shoulder muscle activity and perceived muscular exertion, coupled with increased endurance for holding objects, highlight the potential of this device to mitigate the impact of muscular fatigue for patients with ALS. These results represent a further step toward everyday use of assistive, soft, robotic wearables for the upper limbs.
Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.
23 March 2020 in IEEE Robotics and Automation Letters
Intense therapy is a key factor to improve rehabilitation outcomes. However, when performing rehabilitative stretching with the upper limb of stroke survivors, therapist fatigue is often the limiting factor for the number of repetitions per session. In this work we present an inflatable soft wearable robot aimed at improving severe stroke rehabilitation by reducing therapist fatigue during upper extremity stretching. The device consists of a textile-based inflatable actuator anchored to the torso and arm via functional apparel. Upon inflation, the device creates a moment of force about the glenohumeral joint to counteract effects of gravity and assist in elevating the arm. During a device-assisted (i.e. inflated) standard stretching protocol with a therapist, we showed increased range of motion across five stroke survivors, and reduced muscular activity and cardiac effort by the therapist, when comparing to a vented device condition. Our results demonstrate the potential for this technology to assist a therapist during upper extremity rehabilitation exercises and future studies will explore its impact on increasing dose and intensity of therapy delivered in a given session, with the goal of improving rehabilitation outcomes.
22 February 2021 in IEEE Robotics and Automation Letters
In the field of wearable robotics, there has been increased interest in the creation of soft wearable robots to provide assistance and rehabilitation for those with physical impairments. Compared to traditional robots, these devices have the potential to be fully portable and lightweight, a flexibility that may allow for increased utilization time as well as enable use outside of a clinical environment. In this letter, we present a textile-based multi-joint soft wearable robot to assist the upper limb, in particular shoulder elevation and elbow extension. Before developing a portable fluidic supply system, we leverage an off-board actuation system for power and control, with the worn components weighting less than half kilogram. We showed that this robot can be mechanically transparent when powered off, not restricting users from performing movements associated with activities of daily living. Three IMUs were placed on the torso, upper arm and forearm to measure the shoulder and elbow kinematics. We found an average RMSE of ~ 5 degrees when compared to an optical motion capture system. We implemented dynamic Gravity Compensation (GC) and Joint Trajectory Tracking (JTT) controllers that actively modulated actuator pressure in response to IMU readings. The controller performances were evaluated in a study with eight healthy individuals. Using the GC controller, subject shoulder muscle activity decreased with increasing magnitude of assistance and for the JTT controller, we obtained low tracking errors (mean ~ 6 degrees RMSE). Future work will evaluate the potential of the robot to assist with activities in post-stroke rehabilitation.