Yu Meng Zhou

Yu Meng Zhou

Auto-generated profile, based on publicly available information

Yu Meng Zhou

John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2017 in Science Robotics
Verified
Journal Article
Closed access
PDF file
Giuk LeeGiuk Lee
Giuk Lee
JKJ. Kim
J. Kim
FPF. A. Panizzolo
F. A. Panizzolo
YZY. M. Zhou
Y. M. Zhou
LBL. M. Baker
L. M. Baker
CWC. J. Walsh
C. J. Walsh
A tethered exosuit reduces the metabolic cost of running.

12 June 2024 in Science Robotics
Verified
Journal Article
Closed access
YZYu Meng Zhou
Yu Meng Zhou
CHCameron J. Hohimer
Cameron J. Hohimer
HYHarrison T. Young
Harrison T. Young
CMConnor M. McCann
Connor M. McCann
DPDavid Pont-Esteban
David Pont-Esteban
CWConor J. Walsh
Conor J. Walsh
Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.

22 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
TPTommaso Proietti
Tommaso Proietti
COCiaran O'Neill
Ciaran O'Neill
CHCameron J. Hohimer
Cameron J. Hohimer
KNKristin Nuckols
Kristin Nuckols
MCMegan E. Clarke
Megan E. Clarke
CWConor J. Walsh
Conor J. Walsh
In the field of wearable robotics, there has been increased interest in the creation of soft wearable robots to provide assistance and rehabilitation for those with physical impairments. Compared to traditional robots, these devices have the potential to be fully portable and lightweight, a flexibility that may allow for increased utilization time as well as enable use outside of a clinical environment. In this letter, we present a textile-based multi-joint soft wearable robot to assist the upper limb, in particular shoulder elevation and elbow extension. Before developing a portable fluidic supply system, we leverage an off-board actuation system for power and control, with the worn components weighting less than half kilogram. We showed that this robot can be mechanically transparent when powered off, not restricting users from performing movements associated with activities of daily living. Three IMUs were placed on the torso, upper arm and forearm to measure the shoulder and elbow kinematics. We found an average RMSE of ~ 5 degrees when compared to an optical motion capture system. We implemented dynamic Gravity Compensation (GC) and Joint Trajectory Tracking (JTT) controllers that actively modulated actuator pressure in response to IMU readings. The controller performances were evaluated in a study with eight healthy individuals. Using the GC controller, subject shoulder muscle activity decreased with increasing magnitude of assistance and for the JTT controller, we obtained low tracking errors (mean ~ 6 degrees RMSE). Future work will evaluate the potential of the robot to assist with activities in post-stroke rehabilitation.

16 April 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
CCCarolina Correia
Carolina Correia
KNKristin Nuckols
Kristin Nuckols
DWDiana Wagner
Diana Wagner
YZYu Meng Zhou
Yu Meng Zhou
MCMegan Clarke
Megan Clarke
CWConor J. Walsh
Conor J. Walsh
People with tetraplegia resulting from spinal cord injury experience debilitating hand impairments that may lead to lifelong dependence on others to perform activities of daily living. Wearable robotic devices that actively support hand function during daily living tasks could bring great benefits to this population. In this work, the performance of a textile-based soft robotic glove controlled by the user with a button was evaluated in thirteen participants with tetraplegia. Performance outcomes included activities of daily living using the Jebsen Taylor Hand Function Test, active range of motion of the fingers, and grasp strength for power and pinch grasps. In the Jebsen Test, participants showed significant improvements in performance of activities of daily living with glove assistance, completing a median of 50% more tasks than in their baseline attempt without the glove. Significant improvements were also found for power and pinch grasp forces and active range of motion of the fingers with the glove assistance. Participants with lower baseline motor function received greater benefits from glove assistance. This work demonstrates the effectiveness of a user-controlled textile-based soft robotic glove to improve activity of daily living abilities in individuals with hand impairments resulting from spinal cord injury.

23 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
YZYu Meng Zhou
Yu Meng Zhou
CHCameron Hohimer
Cameron Hohimer
TPTommaso Proietti
Tommaso Proietti
COCiaran Tomas O'NEill
Ciaran Tomas O'NEill
CWConor J. Walsh
Conor J. Walsh
Recent developments in soft active wearable robots can be used for upper extremity injury prevention for healthy industrial workers with better comfort than rigid systems, but there has not been control strategy proposals for such use cases. In this letter, we introduce a kinematics-based controller for an inflatable soft wearable robot that provides assistance to the shoulder quickly and accurately when needed during industrial use cases. Our approach is to use a state machine to classify user intent using shoulder and trunk kinematics estimated with body-worn inertial measurement units. We recruited eight participants to perform various tasks common in the workplace and assessed the controller's intent classification accuracy and response times, by using the users' reactions to cues as their ground truth intentions. On average, we found that the kinematics controller had 99% classification accuracy, and responded 0.8 seconds after the users reacted to the cue to begin work and 0.5 seconds after the users reacted to a cue to stop the task. In addition, we implemented an EMG-based controller for comparison, with state transitions determined by EMG-based thresholds instead of kinematics. Compared to the EMG controller, the kinematics controller required similar time to detect the users' intentions to stop overhead work but an additional 0.17 seconds on average for detecting users' intentions to begin. Although slightly slower, the kinematics controller still provided support prior to users' work initiations. We also implemented an online adaptive tuning algorithm for the kinematics controller to speed up response time while ensuring accuracy during offset transitions. This research paves the way for a further study of kinematics-based controller in a mobile system in real work environments.

1 June 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YZYu Meng Zhou
Yu Meng Zhou
NRNihal Raman
Nihal Raman
TPTommaso Proietti
Tommaso Proietti
JAJames Arnold
James Arnold
PPPrabhat Pathak
Prabhat Pathak
CWConor Walsh
Conor Walsh
The Fugl Meyer Assessment (FMA) is a widely-used assessment for tracking motor function recovery post-stroke. Due to the limited access to rehabilitation, there exists a need for remote and automated assessment solutions. Wearable sensors and data-driven methods have shown promise for enabling automatic upper extremity FMA (FMA-UE) estimation, but minimizing user input motion and aligning with current clinical activities will aid the adoption of sensor-based assessments. In this work, we present an FMA-UE estimator which can make score predictions for a key subset of the assessment (70% of all items) using data from inertial measurement units (IMUs) placed on the arms and the trunk from three volitional reaching motions representative of functional daily activities. We collected a dataset of eleven stroke participants performing a subset of FMA-UE, and three reaching motions. The FMA-UE of each participant was assessed by an occupational therapist providing the labeled score for the training data. The estimator was trained on windowed data during FMA-UE motions and was able to make score estimates from reaching motions. Through leave-one-subjectout cross validation, the estimator achieved a normalized RMSE of 7%, which is comparable to or below the established minimal clinically important difference and minimal detectable change of FMA-UE of post-stroke individuals. Comparison experiments of various model designs also revealed the importance of trunk-based features inspired by compensation strategies common post stroke and features extracted from the hand sensor. The proposed estimator has the potential to broaden the possibility of automatic assessment via wearable sensors.