David Pont-Esteban

David Pont-Esteban

Auto-generated profile, based on publicly available information

David Pont-Esteban

John A. Paulson School of Engineering and Applied Sciences, Harvard University Cambridge Massachusetts USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Science Robotics
Verified
Journal Article
Closed access
YZYu Meng Zhou
Yu Meng Zhou
CHCameron J. Hohimer
Cameron J. Hohimer
HYHarrison T. Young
Harrison T. Young
CMConnor M. McCann
Connor M. McCann
DPDavid Pont-Esteban
David Pont-Esteban
CWConor J. Walsh
Conor J. Walsh
Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.

1 June 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YZYu Meng Zhou
Yu Meng Zhou
NRNihal Raman
Nihal Raman
TPTommaso Proietti
Tommaso Proietti
JAJames Arnold
James Arnold
PPPrabhat Pathak
Prabhat Pathak
CWConor Walsh
Conor Walsh
The Fugl Meyer Assessment (FMA) is a widely-used assessment for tracking motor function recovery post-stroke. Due to the limited access to rehabilitation, there exists a need for remote and automated assessment solutions. Wearable sensors and data-driven methods have shown promise for enabling automatic upper extremity FMA (FMA-UE) estimation, but minimizing user input motion and aligning with current clinical activities will aid the adoption of sensor-based assessments. In this work, we present an FMA-UE estimator which can make score predictions for a key subset of the assessment (70% of all items) using data from inertial measurement units (IMUs) placed on the arms and the trunk from three volitional reaching motions representative of functional daily activities. We collected a dataset of eleven stroke participants performing a subset of FMA-UE, and three reaching motions. The FMA-UE of each participant was assessed by an occupational therapist providing the labeled score for the training data. The estimator was trained on windowed data during FMA-UE motions and was able to make score estimates from reaching motions. Through leave-one-subjectout cross validation, the estimator achieved a normalized RMSE of 7%, which is comparable to or below the established minimal clinically important difference and minimal detectable change of FMA-UE of post-stroke individuals. Comparison experiments of various model designs also revealed the importance of trunk-based features inspired by compensation strategies common post stroke and features extracted from the hand sensor. The proposed estimator has the potential to broaden the possibility of automatic assessment via wearable sensors.

4 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
IAIsabel Alguacil-Diego
Isabel Alguacil-Diego
Alicia Cuesta-GómezAlicia Cuesta-Gómez
Alicia Cuesta-Gómez
ACAldo Contreras
Aldo Contreras
DPDavid Pont-Esteban
David Pont-Esteban
DCDavid Cantalejo
David Cantalejo
MFManuel Ferre
Manuel Ferre
Recovery of therapeutic or functional ambulatory capacity in patients with rotator cuff injury is a primary goal of rehabilitation. Wearable powered exoskeletons allow patients to perform repetitive practice with large movements to maximize recovery, even immediately after the acute event. The aim of this paper is to describe the usability, acceptability and acceptance of a hybrid exoskeleton for upper-limb passive rehabilitation using the System Usability Scale (SUS) questionnaire. This equipment, called ExoFlex, is defined as a hybrid exoskeleton since it is made up of rigid and soft components. The exoskeleton mechanical description is presented along with its control system and the way motion is structured in rehabilitation sessions. Seven patients (six women and one man) have participated in the evaluation of this equipment, which are in the range of 50 to 79 years old. Preliminary evidence of the acceptance and usability by both patients and clinicians are very promising, obtaining an average score of 80.71 in the SUS test, as well as good results in a questionnaire that evaluates the clinicians’ perceived usability of ExoFlex.

20 November 2019
Verified
Book Chapter
Closed access
PDF file
DPDavid Pont
David Pont
ACAldo Contreras
Aldo Contreras
JSJosé Luis Samper
José Luis Samper
FSFrancisco Javier Sáez
Francisco Javier Sáez
MFManuel Ferre
Manuel Ferre
Angel Garcia-BeltranAngel Garcia-Beltran
Angel Garcia-Beltran

26 October 2022 in IEEE Access
Verified
Journal Article
Open access
DPDavid Pont-Esteban
David Pont-Esteban
MSMiguel Angel Sanchez-Uran
Miguel Angel Sanchez-Uran
MFManuel Ferre
Manuel Ferre
Upper-limb exosuits are light wearable devices suitable for applications such as rehabilitation or assistance in industrial environments. One of the main drawbacks of these systems is the amount of uncertainties intrinsic to the nature of the device. Moreover, the direct interaction between the exosuit and its user adds disturbances to the system. Therefore, a robust control architecture to these phenomena is required for its appropriate control. In this article, a robust motion (position and speed) control architecture based on a cascade proportional-integral (PI) and a sliding mode controller (SMC), and a nonlinear disturbance observer (NDO) for the upper-limb cable-driven rehabilitation exosuit LUXBIT is designed. We call the proposed controller by the acronym CPISDO. The SMC nature allows to compensate the matched disturbances and uncertainties, while the NDO counteracts the unmatched ones. The PI component helps in reducing tracking error. Dynamic modelling, system architecture and control design are addressed. The CPISDO controller has been implemented over the exosuit and several experiments have been performed over 10 healthy subjects to evaluate the controller’s tracking performance as well as the disturbance rejection. Supertwisting (a state-of-the-art SMC) and PI controllers have been implemented for CPISDO validation. Results are compared with other state-of-the-art solutions.

1 January 2023
Verified
Book
Open access
EAEsther Aguado
Esther Aguado
FMFernando Alonso Martín
Fernando Alonso Martín
Sergio Altares-LópezSergio Altares-López
Sergio Altares-López
JPJesús Álvarez Pastor
Jesús Álvarez Pastor
JGJosep Amat Girbau
Josep Amat Girbau
KZKexin Zhang
Kexin Zhang