Tianyu Zhang

Mr. Tianyu Zhang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2023 in Optics Letters
Verified
Journal Article
Closed access
TZTianyu Zhang
Tianyu Zhang
SSSimon Shepherd
Simon Shepherd
ZHZhihong Huang
Zhihong Huang
MMMichaelina Macluskey
Michaelina Macluskey
CLChunhui Li
Chunhui Li
Oral cancer, primarily oral squamous cell carcinomas (OSCC), is a major health concern worldwide. The current gold standard for the diagnosis of OSCC is biopsy and histopathological analysis, which is invasive and can place a huge financial burden on the healthcare system. Optical coherence tomography-based angiography (OCTA) is a non-invasive imaging technique that shows promise as an imaging modality to aid the diagnosis of OSCC. This Letter outlines the development of a handheld intraoral OCT probe applied to a swept-source OCT system with an angiography function for oral applications. The probe has a thin body with a diameter of 17.8 mm and a two-lens system with a working distance that is adjustable from 20.92 mm to 24.08 mm, a field of view 9 mm in diameter, an imaging depth of ∼1.7 mm, and resolutions of 39.38 µm (laterally) and 33.37 µm (axially). This probe was used to scan 14 oral sites to evaluate its ability to scan various sites in the oral cavity. This system has the potential to reduce invasive procedures and aid early OSCC diagnosis.

6 September 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
JLJINPENG LIAO
JINPENG LIAO
TZTianyu Zhang
Tianyu Zhang
CLChunhui Li
Chunhui Li
ZHZhihong Huang
Zhihong Huang
Optical coherence tomography (OCT) can be an important tool for non-invasive dermatological evaluation, providing useful data on epidermal integrity for diagnosing skin diseases. Despite its benefits, OCT’s utility is limited by the challenges of accurate, fast epidermal segmentation due to the skin morphological diversity. To address this, we introduce a lightweight segmentation network (LS-Net), a novel deep learning model that combines the robust local feature extraction abilities of Convolution Neural Network and the long-term information processing capabilities of Vision Transformer. LS-Net has a depth-wise convolutional transformer for enhanced spatial contextualization and a squeeze-and-excitation block for feature recalibration, ensuring precise segmentation while maintaining computational efficiency. Our network outperforms existing methods, demonstrating high segmentation accuracy (mean Dice: 0.9624 and mean IoU: 0.9468) with significantly reduced computational demands (floating point operations: 1.131 G). We further validate LS-Net on our acquired dataset, showing its effectiveness in various skin sites (e.g., face, palm) under realistic clinical conditions. This model promises to enhance the diagnostic capabilities of OCT, making it a valuable tool for dermatological practice.

28 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TZTianyu Zhang
Tianyu Zhang
KZKanheng Zhou
Kanheng Zhou
HRHolly R. Rocliffe
Holly R. Rocliffe
APAntonella Pellicoro
Antonella Pellicoro
JCJenna L. Cash
Jenna L. Cash
ZHZhihong Huang
Zhihong Huang
Optical coherence tomography-based angiography (OCTA) has attracted attention in clinical applications as a non-invasive and high-resolution imaging modality. Motion artifacts are the most seen artifact in OCTA. Eigen-decomposition (ED) algorithms are popular choices for OCTA reconstruction, but have limitations in the reduction of motion artifacts. The OCTA data do not meet one of the requirements of ED, which is that the data should be normally distributed. To overcome this drawback, we propose an easy-to-deploy development of ED, windowed-ED (wED). wED applies a moving window to the input data, which can contrast the blood-flow signals with significantly reduced motion artifacts. To evaluate our wED algorithm, pre-acquired dorsal wound healing data in a murine model were used. The ideal window size was optimized by fitting the data distribution with the normal distribution. Lastly, the cross-sectional and en face results were compared among several OCTA reconstruction algorithms, Speckle Variance, A-scan ED (aED), B-scan ED, and wED. wED could reduce the background noise intensity by 18% and improve PSNR by 4.6%, compared to the second best-performed algorithm, aED. This study can serve as a guide for utilizing wED to reconstruct OCTA images with an optimized window size.

6 November 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
JLJINPENG LIAO
JINPENG LIAO
TZTianyu Zhang
Tianyu Zhang
YZYilong Zhang
Yilong Zhang
CLChunhui Li
Chunhui Li
ZHZhihong Huang
Zhihong Huang
Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality for analyzing skin microvasculature, enabling non-invasive diagnosis and treatment monitoring. Traditional OCTA algorithms necessitate at least two-repeated scans to generate microvasculature images, while image quality is highly dependent on the repetitions of scans (e.g., 4-8). Nevertheless, a higher repetition count increases data acquisition time, causing patient discomfort and more unpredictable motion artifacts, which can result in potential misdiagnosis. To address these limitations, we proposed a vasculature extraction pipeline based on the novelty vasculature extraction transformer (VET) to generate OCTA images by using a single OCT scan. Distinct from the vision Transformer, VET utilizes convolutional projection to better learn the spatial relationships between image patches. This study recruited 15 healthy participants. The OCT scans were performed in five various skin sites, i.e., palm, arm, face, neck, and lip. Our results show that in comparison to OCTA images obtained by the speckle variance OCTA (peak-signal-to-noise ratio (PSNR): 16.13) and eigen-decomposition OCTA (PSNR: 17.08) using four repeated OCT scans, OCTA images extracted by the proposed pipeline exhibit a better PSNR (18.03) performance while reducing the data acquisition time by 75%. Visual comparisons show that the proposed pipeline outperformed traditional OCTA algorithms, particularly in the imaging of lip and face areas, where artifacts are commonly encountered. This study is the first to demonstrate that the VET can efficiently extract high-quality vasculature images from a single, rapid OCT scan. This capability significantly enhances diagnostic accuracy for patients and streamlines the imaging process.

5 October 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
JLJINPENG LIAO
JINPENG LIAO
TZTianyu Zhang
Tianyu Zhang
CLChunhui Li
Chunhui Li
ZHZhihong Huang
Zhihong Huang
Oral disorders, including oral cancer, pose substantial diagnostic challenges due to late-stage diagnosis, invasive biopsy procedures, and the limitations of existing non-invasive imaging techniques. Optical coherence tomography angiography (OCTA) shows potential in delivering non-invasive, real-time, high-resolution vasculature images. However, the quality of OCTA images are often compromised due to motion artifacts and noise, necessitating more robust and reliable image reconstruction approaches. To address these issues, we propose a novel model, a U-shaped fusion convolutional transformer (UFCT), for the reconstruction of high-quality, low-noise OCTA images from two-repeated OCT scans. UFCT integrates the strengths of convolutional neural networks (CNNs) and transformers, proficiently capturing both local and global image features. According to the qualitative and quantitative analysis in normal and pathological conditions, the performance of the proposed pipeline outperforms that of the traditional OCTA generation methods when only two repeated B-scans are performed. We further provide a comparative study with various CNN and transformer models and conduct ablation studies to validate the effectiveness of our proposed strategies. Based on the results, the UFCT model holds the potential to significantly enhance clinical workflow in oral medicine by facilitating early detection, reducing the need for invasive procedures, and improving overall patient outcomes.

26 February 2025 in Biomedical Optics Express
Verified
Journal Article
Open access
JLJINPENG LIAO
JINPENG LIAO
TZTianyu Zhang
Tianyu Zhang
SSSimon Shepherd
Simon Shepherd
MMMichaelina Macluskey
Michaelina Macluskey
CLChunhui Li
Chunhui Li
ZHZhihong Huang
Zhihong Huang
Optical coherence tomography (OCT) is promising to become an essential imaging tool for non-invasive oral mucosal tissue assessment, but it faces challenges like speckle noise and motion artifacts. In addition, it is difficult to distinguish different layers of oral mucosal tissues from gray level OCT images due to the similarity of optical properties between different layers. We introduce the Efficient Segmentation-Denoising Model (ESDM), a multi-task deep learning framework designed to enhance OCT imaging by reducing scan time from ∼8s to ∼2s and improving oral epithelium layer segmentation. ESDM integrates the local feature extraction capabilities of the convolution layer and the long-term information processing advantages of the transformer, achieving better denoising and segmentation performance compared to existing models. Our evaluation shows that ESDM outperforms state-of-the-art models with a PSNR of 26.272, SSIM of 0.737, mDice of 0.972, and mIoU of 0.948. Ablation studies confirm the effectiveness of our design, such as the feature fusion methods, which enhance performance with minimal model complexity increase. ESDM also presents high accuracy in quantifying oral epithelium thickness, achieving mean absolute errors as low as 5 µm compared to manual measurements. This research shows that ESDM can notably improve OCT imaging and reduce the cost of accurate oral epithermal segmentation, improving diagnostic capabilities in clinical settings.