Traditional high-quality OCTA images require multi-repeated scans (e.g., 4-8 repeats) in the same position, which may cause the patient to be uncomfortable. We propose a deep-learning-based pipeline that can extract high-quality OCTA images from only two-repeat OCT scans. The performance of the proposed image reconstruction U-Net (IRU-Net) outperforms the state-of-the-art UNet vision transformer and UNet in OCTA image reconstruction from a two-repeat OCT signal. The results demonstrated a mean peak-signal-to-noise ratio increased from 15.7 to 24.2; the mean structural similarity index measure improved from 0.28 to 0.59, while the OCT data acquisition time was reduced from 21 seconds to 3.5 seconds (reduced by 83%).
Fiber-bundle endomicroscopy has several recognized drawbacks, the most prominent being the honeycomb effect. We developed a multi-frame super-resolution algorithm exploiting bundle rotation to extract features and reconstruct underlying tissue. Simulated data was used with rotated fiber-bundle masks to create multi-frame stacks to train the model. Super-resolved images are numerically analyzed, which demonstrates that the algorithm can restore images with high quality. The mean structural similarity index measurement (SSIM) improved by a factor of 1.97 compared with linear interpolation. The model was trained using images taken from a single prostate slide, 1343 images were used for training, 336 for validation, and 420 for testing. The model had no prior information about the test images, adding to the robustness of the system. Image reconstruction was completed in 0.03 s for 256 × 256 images indicating future real-time performance is within reach. The combination of fiber bundle rotation and multi-frame image enhancement through machine learning has not been utilized before in an experimental setting but could provide a much-needed improvement to image resolution in practice.
Optical coherence tomography (OCT) can be an important tool for non-invasive dermatological evaluation, providing useful data on epidermal integrity for diagnosing skin diseases. Despite its benefits, OCT’s utility is limited by the challenges of accurate, fast epidermal segmentation due to the skin morphological diversity. To address this, we introduce a lightweight segmentation network (LS-Net), a novel deep learning model that combines the robust local feature extraction abilities of Convolution Neural Network and the long-term information processing capabilities of Vision Transformer. LS-Net has a depth-wise convolutional transformer for enhanced spatial contextualization and a squeeze-and-excitation block for feature recalibration, ensuring precise segmentation while maintaining computational efficiency. Our network outperforms existing methods, demonstrating high segmentation accuracy (mean Dice: 0.9624 and mean IoU: 0.9468) with significantly reduced computational demands (floating point operations: 1.131 G). We further validate LS-Net on our acquired dataset, showing its effectiveness in various skin sites (e.g., face, palm) under realistic clinical conditions. This model promises to enhance the diagnostic capabilities of OCT, making it a valuable tool for dermatological practice.
Optical coherence tomography (OCT) has attracted attention in dermatology applications for skin disease characterization and diagnosis because it provides high-resolution (<10 μm) of tissue non-invasively with high imaging speed (2–8 s). However, the quality of OCT images can be significantly degraded by speckle noise, which results from light waves scattering in multiple directions. This noise can hinder the accuracy of disease diagnosis, and the conventional frame averaging method requires multiple repeated (e.g., four to six) scans, which is time consuming and introduces motion artifacts. To overcome these limitations, we proposed a lightweight U-shape Swin (LUSwin) transformer-based denoising pipeline to recover high-quality OCT images from the noisy OCT images by utilizing a fast one-repeated OCT scan. In terms of the peak signal-to-noise-ratio (PSNR) performance, the results reveal that the denoised images from the LUSwin transformer (26.92) are of a higher quality than the four-repeated frame-averaging method (26.19). Compared to the state-of-the-art networks in image denoising, the proposed LUSwin transformer has the smallest floating points operation (3.9299 G) and has the second highest PSNR results, only 0.02 lower than the Swin-UNet, which has the highest PSNR results (26.94). This study demonstrates that the transformer model has the capacity to denoise the noisy OCT image from a fast one-repeated OCT scan.
6 November 2023 in IEEE Transactions on Biomedical Engineering
Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality for analyzing skin microvasculature, enabling non-invasive diagnosis and treatment monitoring. Traditional OCTA algorithms necessitate at least two-repeated scans to generate microvasculature images, while image quality is highly dependent on the repetitions of scans (e.g., 4-8). Nevertheless, a higher repetition count increases data acquisition time, causing patient discomfort and more unpredictable motion artifacts, which can result in potential misdiagnosis. To address these limitations, we proposed a vasculature extraction pipeline based on the novelty vasculature extraction transformer (VET) to generate OCTA images by using a single OCT scan. Distinct from the vision Transformer, VET utilizes convolutional projection to better learn the spatial relationships between image patches. This study recruited 15 healthy participants. The OCT scans were performed in five various skin sites, i.e., palm, arm, face, neck, and lip. Our results show that in comparison to OCTA images obtained by the speckle variance OCTA (peak-signal-to-noise ratio (PSNR): 16.13) and eigen-decomposition OCTA (PSNR: 17.08) using four repeated OCT scans, OCTA images extracted by the proposed pipeline exhibit a better PSNR (18.03) performance while reducing the data acquisition time by 75%. Visual comparisons show that the proposed pipeline outperformed traditional OCTA algorithms, particularly in the imaging of lip and face areas, where artifacts are commonly encountered. This study is the first to demonstrate that the VET can efficiently extract high-quality vasculature images from a single, rapid OCT scan. This capability significantly enhances diagnostic accuracy for patients and streamlines the imaging process.
Oral disorders, including oral cancer, pose substantial diagnostic challenges due to late-stage diagnosis, invasive biopsy procedures, and the limitations of existing non-invasive imaging techniques. Optical coherence tomography angiography (OCTA) shows potential in delivering non-invasive, real-time, high-resolution vasculature images. However, the quality of OCTA images are often compromised due to motion artifacts and noise, necessitating more robust and reliable image reconstruction approaches. To address these issues, we propose a novel model, a U-shaped fusion convolutional transformer (UFCT), for the reconstruction of high-quality, low-noise OCTA images from two-repeated OCT scans. UFCT integrates the strengths of convolutional neural networks (CNNs) and transformers, proficiently capturing both local and global image features. According to the qualitative and quantitative analysis in normal and pathological conditions, the performance of the proposed pipeline outperforms that of the traditional OCTA generation methods when only two repeated B-scans are performed. We further provide a comparative study with various CNN and transformer models and conduct ablation studies to validate the effectiveness of our proposed strategies. Based on the results, the UFCT model holds the potential to significantly enhance clinical workflow in oral medicine by facilitating early detection, reducing the need for invasive procedures, and improving overall patient outcomes.