Nonlinear dynamical systems such as weakly coupled oscillators are an interesting approach to be adopted for the regulation of power inverters inside microgrids. Aiming at the synchronization and load sharing in islanded mirogrid, this article is inspired by oscillator synchronization property to propose a Hopf oscillator controller for the single-phase inverters. The Hopf oscillator dynamic equations are used for providing the inverter's frequency and amplitude voltage references, which lead to a robust nonlinear droop behavior for driving the system without using communications. The Hopf oscillator provides better sharing of the load between inverters with higher robustness, less harmonic distortion, and faster time response of the associated limit cycle than the achieved by the other approach made with a Van der Pol oscillator. In addition, global asymptotic synchronization of system is proven by Lyapunov approach. Simulation results of a system composed by paralleled inverters are provided and compared with a Van der Pol oscillator approach reported in literature. Experimental results are also provided to prove the Hopf oscillator based controller under different circumstances.
15 July 2022 in IEEE Transactions on Power Systems
With the increasing application of synchronverter technology in renewable energy power generation, power system stability issue becomes more complicated. Due to the impedance interaction between the synchronverter based wind farm and the series compensated transmission line, the synchronverter based wind farm is prone to cause sub-synchronous oscillation (SSO). To suppress this SSO, a generalized harmonic compensation control strategy of active power filter (APF) with supercapacitor is proposed, which counteracts SSO by injecting the generalized harmonic current including reactive and oscillation current. Since the generalized harmonic current can be calculated by subtracting the sinusoidal active current from the sampling current, a first-order inertial controller of the voltage loop for APF is proposed to accurately obtain the active current. In addition, the supercapacitor of APF is used to reduce the dc-side voltage fluctuation caused by SSO. As this paper does not need to directly extract the SSO component, the proposed method does not need to know the system oscillation frequency in advance, which can be used as a defensive control method of SSO. Finally, experimental results verify the effectiveness of the proposed strategy.
The active and reactive powers, P and Q, are crucial variables in the parallel operation of single-phase inverters using the droop method, introducing proportional droops in the inverter output frequency and voltage amplitude references. P and Q, or P-Q, are calculated as the product of the inverter output voltage and its orthogonal version with the output current, respectively. However, when sharing nonlinear loads these powers, Pav and Qav, should be averaged by low-pass filters (LPFs) with a very low cut-off frequency to avoid the high distortion induced by these loads. This forces the droop method to operate at a very low dynamic velocity and degrades the system stability. Then, different solutions have been proposed in literature to increase the system velocity, but only considering linear loads. Therefore, this work presents a method to calculate Pav and Qav using second-order generalized integrators (SOGI) to face this problem with nonlinear loads. A double SOGI (DSOGI) approach is applied to filter the nonlinear load current and provide its fundamental component to the inverter, leading to a faster dynamic velocity of the droop-based load sharing capability and improving the stability. The proposed method is shown to be faster than others in the literature when considering nonlinear loads, while smoothly driving the system with low distortion levels. Simulations, hardware-in-loop (HIL) and experimental results are provided to validate this proposal.
The dynamic performance of the local control of single-phase voltage source inverters (VSIs) can be degraded when supplying to nonlinear loads (NLLs) in microgrids. When this control is based on the droop principles, a proper calculation of the active and reactive averaged powers (P–Q) is essential for a proficient dynamic response against abrupt NLL changes. In this work, a VSI supplying to an NLL was studied, focusing the attention on the P–Q calculation stage. This stage first generated the direct and in-quadrature signals from the measured load current through a second-order generalized integrator (SOGI). Then, the instantaneous power quantities were obtained by multiplying each filtered current by the output voltage, and filtered later by utilizing a SOGI to acquire the averaged P–Q parameters. The proposed algorithm was compared with previous proposals, while keeping the active power steady-state ripple constant, which resulted in a faster calculation of the averaged active power. In this case, the steady-state averaged reactive power presented less ripple than the best proposal to which it was compared. When reducing the velocity of the proposed algorithm for the active power, it also showed a reduction in its steady-state ripple. Simulations, hardware-in-the-loop, and experimental tests were carried out to verify the effectiveness of the proposal.
The power calculation is an indispensable element in droop-controlled inverters because the bandwidth of the measured power has a direct impact on the controller performance. This paper proposes a fast and accurate power calculation algorithm based on the combined Second Order Generalized Integrator (SOGI) filters in stationary coordinates for a three-phase system, which takes into consideration the use of nonlinear loads. The power calculation scheme is formed by the two-stage SOGI filters that are employed for obtaining the active and reactive powers required to perform a droop-based inverter operation, respectively. From the two-stage structure, the first SOGI is used as a band-pass filter (BPF) for filtering harmonics and obtaining the fundamental current of the nonlinear load; The second SOGI is used as a low-pass filter (LPF) for extracting the DC-component, which corresponds with the average power. A small-signal model of a two droop-controlled inverters system is built to obtain the dynamical response and stability margin of the system. And compared it with the dynamical behaviour of a standard droop-control method. Next, the proposed power calculation system is designed in order to achieve the same ripple amplitude voltage as that obtained with the standard droop-control method by adjusting the bandwidth gains. Through simulation and hardware in the loop (HIL) validation, the proposed approach presents a faster and more accurate performance when sharing nonlinear loads, and also drives the inverters’ output voltage with lower distortion.