This work presents a phase-locked loop (PLL) algorithm adequate for applications regarding single-phase power grids. The proposed approach is based on the correlation of the input signal with a complex one obtained from an adaptive filter aiming at minimizing computational burden and increase accuracy if compared with a former algorithm previously proposed in literature. Thus it is possible to obtain high disturbance rejection, especially when dealing with the presence of subharmonics and interharmonics in the frequency spectrum of the supply voltage. Performance is thoroughly evaluated through experimental tests considering both steady-state and dynamic behaviors, while a proper comparison is established with other similar solutions.
23 September 2022 in Electric Power Systems Research
The power calculation is an indispensable element in droop-controlled inverters because the bandwidth of the measured power has a direct impact on the controller performance. This paper proposes a fast and accurate power calculation algorithm based on the combined Second Order Generalized Integrator (SOGI) filters in stationary coordinates for a three-phase system, which takes into consideration the use of nonlinear loads. The power calculation scheme is formed by the two-stage SOGI filters that are employed for obtaining the active and reactive powers required to perform a droop-based inverter operation, respectively. From the two-stage structure, the first SOGI is used as a band-pass filter (BPF) for filtering harmonics and obtaining the fundamental current of the nonlinear load; The second SOGI is used as a low-pass filter (LPF) for extracting the DC-component, which corresponds with the average power. A small-signal model of a two droop-controlled inverters system is built to obtain the dynamical response and stability margin of the system. And compared it with the dynamical behaviour of a standard droop-control method. Next, the proposed power calculation system is designed in order to achieve the same ripple amplitude voltage as that obtained with the standard droop-control method by adjusting the bandwidth gains. Through simulation and hardware in the loop (HIL) validation, the proposed approach presents a faster and more accurate performance when sharing nonlinear loads, and also drives the inverters’ output voltage with lower distortion.
This work aims to analyze and validate through mathematical modeling and experimental results, in a three-phase three-wire electrical system, the technical viability of a static power converter with a two-level topology with only two controlled branches (2L2B), operating as a grid-side converter (GSC) in a wind turbine generator based on a doubly fed induction generator (DFIG). With this reduced-switches topology, the GSC is able to regulate the DC-link voltage level from the generator back-to-back converter and provide ancillary services of harmonic filtering and reactive power compensation from linear/nonlinear loads connected to the point of common coupling. An 8-kVA experimental prototype was implemented in the laboratory to validate the proposal. The prototype control system was realized using the dSPACE DS1103 PPC Controller Board platform programmed via MATLAB/Simulink. The effectiveness of the proposed system is verified by comparing the results obtained with the 2L2B topology to the ones with the usual two-level three-branch topology.
This paper analyzes the performance of two synchronization algorithms, the EPLL and the ISI-PLL, under scenarios where inter-harmonics and sub-harmonics distortion are present in the input signals. Synchronization algorithms main goals are to estimate, with high accuracy, power grid parameters such as frequency and phase-angle. The EPLL is a well-known structure that is widely studied in the literature, whereas the ISI-PLL is a recent proposal. In order to obtain experimental results, both structures were implemented in the hardware-in-the-loop (HIL) dSPACE 1103 platform. Results showed that where the proposed structure is highly accurate under the considered scenarios, the EPLL estimation is not as precise.