Filip Hrncirik

Dr. Filip Hrncirik

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2023 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Filip HrncirikFilip Hrncirik
Filip Hrncirik
IRIwan Roberts
Iwan Roberts
ISIlkem Sevgili
Ilkem Sevgili
CSChloe Swords
Chloe Swords
MBManohar Bance
Manohar Bance
As the first clinically translated machine-neural interface, cochlear implants (CI) have demonstrated much success in providing hearing to those with severe to profound hearing loss. Despite their clinical effectiveness, key drawbacks such as hearing damage, partly from insertion forces that arise during implantation, and current spread, which limits focussing ability, prevent wider CI eligibility. In this review, we provide an overview of the anatomical and physical properties of the cochlea as a resource to aid the development of accurate models to improve future CI treatments. We highlight the advancements in the development of various physical, animal, tissue engineering, and computational models of the cochlea and the need for such models, challenges in their use, and a perspective on their future directions.

10 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Filip HrncirikFilip Hrncirik
Filip Hrncirik
Iwan Vaughan RobertsIwan Vaughan Roberts
Iwan Vaughan Roberts
CSChloe Swords
Chloe Swords
PCPeter J. Christopher
Peter J. Christopher
MCMohammed Chhabu
Mohammed Chhabu
MBManohar Bance
Manohar Bance
(1) Background: During a cochlear implant insertion, the mechanical trauma can cause residual hearing loss in up to half of implantations. The forces on the cochlea during the insertion can lead to this mechanical trauma but can be highly variable between subjects which is thought to be due to differing anatomy, namely of the scala tympani. This study presents a systematic investigation of the influence of different geometrical parameters of the scala tympani on the cochlear implant insertion force. The influence of these parameters on the insertion forces were determined by testing the forces within 3D-printed, optically transparent models of the scala tympani with geometric alterations. (2) Methods: Three-dimensional segmentations of the cochlea were characterised using a custom MATLAB script which parametrised the scala tympani model, procedurally altered the key shape parameters (e.g., the volume, vertical trajectory, curvature, and cross-sectional area), and generated 3D printable models that were printed using a digital light processing 3D printer. The printed models were then attached to a custom insertion setup that measured the insertion forces on the cochlear implant and the scala tympani model during a controlled robotic insertion. (3) Results: It was determined that the insertion force is largely unaffected by the overall size, curvature, vertical trajectory, and cross-sectional area once the forces were normalised to an angular insertion depth. A Capstan-based model of the CI insertion forces was developed and matched well to the data acquired. (4) Conclusion: By using accurate 3D-printed models of the scala tympani with geometrical alterations, it was possible to demonstrate the insensitivity of the insertion forces to the size and shape of the scala tympani, after controlling for the angular insertion depth. This supports the Capstan model of the cochlear implant insertion force which predicts an exponential growth of the frictional force with an angular insertion depth. This concludes that the angular insertion depth, rather than the length of the CI inserted, should be the major consideration when evaluating the insertion force and associated mechanical trauma caused by cochlear implant insertion.

22 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Filip HrncirikFilip Hrncirik
Filip Hrncirik
Leo NagyLeo Nagy
Leo Nagy
HGHannah L. Grimes
Hannah L. Grimes
HIHaissan Iftikhar
Haissan Iftikhar
JMJameel Muzaffar
Jameel Muzaffar
MBManohar Bance
Manohar Bance
Cochlear implants are crucial for addressing severe-to-profound hearing loss, with the success of the procedure requiring careful electrode placement. This scoping review synthesizes the findings from 125 studies examining the factors influencing insertion forces (IFs) and intracochlear pressure (IP), which are crucial for optimizing implantation techniques and enhancing patient outcomes. The review highlights the impact of variables, including insertion depth, speed, and the use of robotic assistance on IFs and IP. Results indicate that higher insertion speeds generally increase IFs and IP in artificial models, a pattern not consistently observed in cadaveric studies due to variations in methodology and sample size. The study also explores the observed minimal impact of robotic assistance on reducing IFs compared to manual methods. Importantly, this review underscores the need for a standardized approach in cochlear implant research to address inconsistencies and improve clinical practices aimed at preserving hearing during implantation.

7 November 2024 in International Journal of Extreme Manufacturing
Verified
Journal Article
Open access
Jinke ChangJinke Chang
Jinke Chang
SCSita Tarini Clark
Sita Tarini Clark
Iwan Vaughan RobertsIwan Vaughan Roberts
Iwan Vaughan Roberts
Filip HrncirikFilip Hrncirik
Filip Hrncirik
ZZZhipeng Zhang
Zhipeng Zhang
MBManohar Bance
Manohar Bance
The cochlea is one of the most complex organs in the human body, exhibiting a complex interplay of characteristics in acoustic, mechanical, electrical, and biological functions. Functional cochlea models are an essential platform for studying hearing mechanics and are crucial for developing next-generation auditory prostheses and artificial hearing systems for sensorineural hearing restoration. Recent advances in additive manufacturing, organ-on-a-chip models, drug delivery platforms, and artificial intelligence have provided valuable insights into how to manufacture artificial cochlea models that more accurately replicate the complex anatomy and physiology of the inner ear. This paper reviews recent advancements in the applications of advanced manufacturing techniques in reproducing the physical, biological, and intelligent functions of the cochlea. It also outlines the current challenges to developing mechanically, electrically, and anatomically accurate functional models of the inner ear. Finally, this review identifies the major requirements and outlook for impactful research in this field going forward. Through interdisciplinary collaboration and innovation, these functional cochlea models are poised to drive significant advancements in hearing treatments, and ultimately enhance the quality of life for individuals with hearing loss.

15 May 2023
Verified
Conference Paper
Closed access
ATA. Tamboli
A. Tamboli
AKA. Kale
A. Kale
Filip HrncirikFilip Hrncirik
Filip Hrncirik
BBBabak Bakhit
Babak Bakhit
AFA.J. Flewitt
A.J. Flewitt
MRM. Miguel Ramos
M. Miguel Ramos
In this work, we report a novel ovenized dual-mode solidly mounted resonator for potential applications in gravimetric sensing. We propose using a resistive micro-heater embedded within the resonator structure for ovenization to achieve highly localized heating for frequency tuning. Also, the dual-mode structure has two resonance modes with opposite reactions to temperatures owing to their temperature coefficient of frequency (TCF) which we utilize as a thermometer. In this proof-of-concept work, we demonstrate the frequency tuning achieved by using joule heating resulting from the micro-heater. The tuning efficiency for Mode I and II of the dual-mode device was observed to be 7.6 ppm/mW and -9.641 ppm/mW, respectively.

17 July 2026 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
PDF file
CSChloe Swords
Chloe Swords
Iwan Vaughan RobertsIwan Vaughan Roberts
Iwan Vaughan Roberts
SCSita Tarini Clark
Sita Tarini Clark
Filip HrncirikFilip Hrncirik
Filip Hrncirik
BHBotian Huang
Botian Huang
MBManohar Bance
Manohar Bance
Objectives: Cochlear implants (CIs) can restore hearing to individuals with severe deafness, yet clinical outcomes vary widely because it remains difficult to predict how electrical currents interact with the unique anatomy of each cochlea. A central challenge in auditory rehabilitation is the lack of experimental systems that capture both the anatomical fidelity and the electrical properties of the human cochlea. To address this need, we developed electroanatomic twins: three‐dimensional, 3D printed models of human cochleae that incorporate anatomically accurate features of the otic capsule and conductive biomimetic structures designed to reproduce tissue resistivity. Methods: Electroanatomic cochlea twins were generated from high resolution microCT scans of cadaveric specimens and from clinical CT scans, and they allowed reproducible, high‐resolution mapping of voltage fields during CI stimulation. Results: These models reproduced intraoperative spread of current profiles with a root mean square error below 0.1 kΩ, closely matched cadaveric impedance spectra, and recapitulated spatial voltage distributions under monopolar, bipolar, and tripolar stimulation. Conclusion: By combining anatomical precision with electrical realism, electroanatomic twins provide a robust translational platform for systematic testing of electrode designs and programming strategies. This approach has the potential to guide individualized CI programming and thereby improve auditory outcomes, while also establishing a generalisable framework for modeling electroanatomic interactions that could accelerate the development of personalized bioelectronic therapies. Level of Evidence: Level 3.