Mimi Min

Dr. Mimi Min

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
MMMimi Min
Mimi Min
CYCheolhee Yoon
Cheolhee Yoon
NYNarin Yoo
Narin Yoo
JKJinseo Kim
Jinseo Kim
YYYeo Song Yoon
Yeo Song Yoon
Seungho JungSeungho Jung
Seungho Jung
The transition to hydrogen as a clean energy source is critical for addressing climate change and supporting environmental sustainability. This review provides an accessible summary of general research trends in hydrogen risk assessment methodologies, enabling diverse stakeholders, including researchers, policymakers, and industry professionals, to gain insights into this field. By examining representative studies across theoretical, experimental, and simulation-based approaches, the review highlights prominent trends and applications within academia and industry. The key focus is on evaluating risks in stationary and transportation applications, paying particular attention to hydrogen storage systems, transportation infrastructures, and energy systems. By offering a concise yet informative summary of hydrogen risk assessment trends, this paper aims to serve as a foundational resource for fostering safer and more sustainable hydrogen systems.

13 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
HKHyunjun Kwak
Hyunjun Kwak
MKMinji Kim
Minji Kim
MMMimi Min
Mimi Min
BPByoungjik Park
Byoungjik Park
Seungho JungSeungho Jung
Seungho Jung
Hydrogen refueling stations (HRS) operating at high pressures pose a higher risk of leakage than conventional gas stations. Therefore, in this study, a quantitative risk assessment (QRA) was conducted using DNV-GL SAFETI v.8.9. The impact of the shutoff valve was quantitatively assessed, and step-by-step mitigation was applied to propose the minimum installation requirements for the valve necessary to achieve broadly acceptable risk levels. The QRA includes sequence analysis (CA), individual risk (IR), and societal risk (SR), with accident scenarios consisting of catastrophic ruptures and three leak scenarios. The research results indicate that the application of a dual shutoff valve system resulted in an IR of 7.48 × 10−5, effectively controlling the risk below the as low as reasonably practicable (ALARP) criteria of the Health and Safety Executive (HSE). The SR was analyzed based on the ALARP criteria in the Netherlands, and the application of the dual shutoff valve system effectively controlled the risk below the ALARP criteria. Consequently, this study suggests that applying a dual shutoff valve system with a mitigation value exceeding 1.21 × 10−2 can successfully mitigate the risk of urban hydrogen refueling stations to broadly acceptable levels.

27 February 2025 in Processes
Verified
Journal Article
Open access
PDF file
JPJuwon PARK
Juwon PARK
KLKeunwon Lee
Keunwon Lee
MMMimi Min
Mimi Min
CPChuntak Phark
Chuntak Phark
Seungho JungSeungho Jung
Seungho Jung
Chemical plants inherently handle and operate with a wide range of hazardous materials, making them more prone to accidents compared to other industrial sectors. Consequently, safety management in chemical plants tends to be systematically organized based on elements of process safety management (PSM) systems. In June 2023, South Korea’s Ministry of Employment and Labor released the Serious Injury and Fatality (SIF) report, which summarized 4432 major accident cases that occurred over six years (2016–2021), including 1834 cases in manufacturing and related industries and 2574 cases in construction. The report provided an overview of these accidents, their causes, and measures to prevent their recurrence, with a focus on fatalities and severe injuries associated with critical losses across different industries. This study examined 16 accident cases that occurred at PSM-regulated facilities, which are managed on the basis of a systematic safety framework established by regulatory requirements. Among these, particular attention was paid to an explosion accident in the organic catalyst packaging process at a facility with no prior accident history and exhibiting unique accident characteristics. A systemic root cause analysis was conducted using the barrier-based systemic cause analysis technique (BSCAT) and the system theoretic accident model and process (STAMP-CAST) methodologies. The systemic analysis highlighted the critical importance of clearly identifying materials or factors that may inadvertently mix during the process design or mass production phases and evaluating whether such interactions could lead to accidents during the hazard assessment stage. Beyond incorporating the risk mitigation measures identified in the process design and procedural development phases without omissions, it is essential to periodically conduct “worker-centered risk assessments”. These assessments help evaluate the potential for accidents resulting from human errors, such as workers’ non-compliance with established procedures, which is a key aspect of preventing chemical accidents. Although this study did not include an evaluation of the impacts of high pressures or high temperatures on workers near chemical accident sites—hence, no specific recommendations regarding safe working distances are made—the findings are expected to contribute to the development of preventive measures for chemical accidents in smaller-scale plants where workers directly manage and operate processes.

15 July 2025 in Korean Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
CYCheolhee Yoon
Cheolhee Yoon
BBBoo-Hyoung Bang
Boo-Hyoung Bang
KLKeunwon Lee
Keunwon Lee
Seungho JungSeungho Jung
Seungho Jung
MMMimi Min
Mimi Min

11 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
MMMimi Min
Mimi Min
KLKwangho Lee
Kwangho Lee
Seungho JungSeungho Jung
Seungho Jung
In the semiconductor industry, hydrogen is used with many other hazardous and dangerous substances with flammable, toxic, and corrosive properties. In order to safely handle them, convenient-to-use gas cabinets are often required. As known well, hydrogen is highly flammable and explosive, and risk analysis needs to safely use the gas in the cabinets. In this study, overpressure and impact according to various gas cabinet conditions were measured when hydrogen leaks in the gas cabinet, and the effect of overpressure on the protective wall was simulated. For the research, a demonstration experiment was conducted by custom manufacturing a gas cylinder cabinet identical to the standard used in the field, and the protection performance analysis was performed by reverse-engineering it through 3D scanning. As a result of the demonstration experiment, the maximum pressure at the time of hydrogen gas explosion in the gas cylinder cabinet was measured at 0.3 bar. After calculating the detonation pressure propagation profile using the TNT equivalence method, the protective performance of the protective wall was confirmed using AUTODYN. The maximum stress of the concrete and the maximum stress of the reinforcing bar due to the explosion in the gas cylinder cabinet were calculated to be 30.211 MPa and 112.88 MPa, respectively, which do not exceed the tensile strength of concrete and the yield strength of the reinforcing bar. This result is expected to be of great help to the development of the semiconductor industry by suggesting the rationale for mitigating the firewall when changing the semiconductor layout.

NSNamjeong Son
Namjeong Son
YKYoojin Kim
Yoojin Kim
MMMimi Min
Mimi Min
Seungho JungSeungho Jung
Seungho Jung
Chankyu KangChankyu Kang
Chankyu Kang
Leakage accidents at chemical facilities have a negative impact on both the environment and human life, and the government has established and implemented regulations on dikes in order to minimize such accidents. However, the overtopping phenomenon in which chemicals overflow the dike due to catastrophic leakage requires additional safeguards. In this study, the mitigation effect was confirmed by simulating tanks and dikes using various deflector plates to minimize the effect of spilled chemicals. ANSYS Fluent 19.1, a computational fluid dynamics program, was used, and the overtopping effect was compared with a dike design that satisfies the safety regulations using a volume of fluid (VOF) model that analyzes multiphase flow through a surface tracking technique. Nitric acid and sulfuric acid were used in the study; they were selected because they are frequently involved in leakage accidents. In the event of a leak in a liquid tank, a dike with a deflector plate was very effective in reducing overtopping, and a deflector at a 45° angle was more effective than a 30° deflector. However, it is necessary to install additional safeguards at the joint between the dike and the deflection plate to withstand the force of the liquid.