Xianshun Shen

Dr. Xianshun Shen


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
XSXianshun Shen
Xianshun Shen
JTJun Tao
Jun Tao
YWYanan Wu
Yanan Wu
TDTianbai Deng
Tianbai Deng
QZQianlong Zhu
Qianlong Zhu
FPFeixiang Peng
Feixiang Peng
The hybrid active power filter (HAPF) can effectively suppress the 75–125 Hz low-frequency harmonic current generated by the EAST poloidal field power supply. However, the low-frequency harmonic current suppression performance of HAPF is greatly affected by its control parameters when the circuit parameters are determined. In this paper, the state–space equation of the HAPF system is established, and the relationship between the eigenvalues of the state–space matrix and the HAPF control parameters is analyzed using the Lyapunov method. Based on the variation law of the eigenvalues, by optimizing the control parameters of the HAPF system, the low-frequency harmonic current suppression performance of HAPF is improved by 41.9%.

5 August 2024 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
TDTianbai Deng
Tianbai Deng
TYTao Yuan
Tao Yuan
JTJun Tao
Jun Tao
XSXianshun Shen
Xianshun Shen
SHSong Han
Song Han
CMChong Mei
Chong Mei
During the operation of the ITER machine, hundreds of MW/Var of active and reactive power will be exchanged with the grid. The E‐STATCOM scheme composed of the Modular Multilevel Converter (MMC) and split supercapacitor energy storage has been proposed to improve the power compensation performance of the existing reactive power compensation system in the previous study. However, one of the main technical challenges which is lack of research is to precharge all submodule capacitors and supercapacitors from zero to their nominal voltage values efficiently during a startup process. As the capacitance and operating voltage of supercapacitors are much different from capacitors in each submodule, the startup of E‐STATCOM is a more complicated process. To coordinate the energy exchange between submodule capacitors and supercapacitors, submodule capacitors and the grid, this paper presents an optimized four‐stage AC side startup strategy for the E‐STATCOM. The proposed method minimizes the use of current‐limiting resistors while suppressing the surge current in the zero‐voltage startup process of supercapacitors, in addition to optimizing the energy consumption. The pulse current charging, constant current charging and constant power charging strategies of supercapacitors are adopted in different charging stages, and the detailed coordinated control scheme between submodule capacitors and supercapacitors are described and analyzed. The effectiveness and performance of the proposed method are verified by simulation results and hardware‐in‐the‐loop (HIL) experiments.

12 May 2026 in Plasma Science and Technology
Verified
Journal Article
Closed access
TDTianbai Deng
Tianbai Deng
YYYue Yan
Yue Yan
ZYZhengyang Ye
Zhengyang Ye
JTJun Tao
Jun Tao
XSXianshun Shen
Xianshun Shen
DKDefeng Kong
Defeng Kong
The compact torus injection (CTI) technology utilizes the electromagnetic force to inject the compact torus (CT) plasma as a fuel carrier into the core of a nuclear fusion reactor. However, the performance of a CTI system is constrained by its pulsed power supplies which working under high current condition with microsecond pulse width. This paper presents a solid-state solution to improve the repetition performance and energy efficiency of microseconds pulsed power supplies for CTI systems based on high-current thyristors (GTO-like) and the active energy recovery technology. The structural, forward and reverse blocking characteristics of the GTO-like thyristor were analyzed. Then the topology was designed for both measuring the blocking recovery characteristics of devices and enhancing the efficiency of the pulsed power supplies system. The prototype experimental results show that 8 Hz repetitive operation with 112 kA peak current was achieved at 5.5 kV, the maximum energy recovery rate reached 31.1%, which is 6.8 percentage points higher than that of the traditional energy recovery topology.