George Callender

Dr. George Callender


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2018 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
GCGeorge Callender
George Callender
IGIgor O Golosnoy
Igor O Golosnoy
PRPaolo Rapisarda
Paolo Rapisarda
PLPaul Lewin
Paul Lewin
In this paper partial discharge (PD) is investigated inside a spherical air filled void at atmospheric pressure using a drift diffusion model. Discharge dynamics consisted of an electron avalanche transitioning into positive streamer, in agreement with earlier work on dielectric barrier discharges. Different model configurations were utilised to test many of the concepts employed in semi-analytical PD activity models, which use simplistic descriptions of the discharge dynamics. The results showed that many of these concepts may be erroneous, with significant discrepancies between the canonical reasoning and the simulation results. For example, the residual electric field, the electric field after a discharge, is significantly lower than the estimates used by classical PD activity models in the literature.

2 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ADAtip Doolgindachbaporn
Atip Doolgindachbaporn
GCGeorge Callender
George Callender
PLPaul Lewin
Paul Lewin
ESEdward Simonson
Edward Simonson
GWGordon Wilson
Gordon Wilson
Condition monitoring of power transformers, which are key components of electrical power systems, is essential to identify incipient faults and avoid catastrophic failures. In this paper machine learning algorithms, i.e., nonlinear autoregressive neural networks and support vector machines, are proposed to model the transformer thermal behavior for the purpose of monitoring. The thermal models are developed based on the historical measurements from nine transformers comprised of two 180-MVA units, four 240-MVA units and three 1000-MVA units. The data consist of load profile, tap position, winding indicator temperature (WTI) measurement, ambient temperature, wind speed and solar radiation. The results are validated against field measurements, and it is clearly demonstrated that the alternative algorithms surpass the IEEE Annex G thermal model. An incipient thermal fault identification algorithm is then proposed and successfully used to identify an issue using measurements taken in the field. This algorithm could be used to alert the operator and plan intervention accordingly.

28 November 2018 in Journal of Physics D: Applied Physics
Verified
Journal Article
Open access
PDF file
GCGeorge Callender
George Callender
TTThanarat Tanmaneeprasert
Thanarat Tanmaneeprasert
PLPaul Lewin
Paul Lewin
Partial discharge (PD) activity models typically use simplified descriptions of individual discharges to develop a model of discharge activity. This approach neglects the plasma dynamics of the discharge, and requires the use of multiple assumptions. In this work, plasma dynamic simulations of individual PDs are used to inform a PD activity model for discharges within a cylindrical cavity bounded by low density polyethylene. Specifically, by considering the plasma dynamics of the discharges it is possible to determine: surface charge density distributions, apparent charges, the inception electric field and the residual electric field. The resulting PD activity model had only a single adjustable parameter, relating to the availability of seed charges, and was able to produce phase resolved PD patterns that were comparable with experimental data. Good agreement was also observed between the measured and simulated PD extinction voltage. The shortcomings of PD activity models are discussed including the poor understanding of the seed charge generation rate. Nevertheless, the model does allow robust conclusions on the PD dynamics in the experiment. The main contribution of this work is to show how simulations of plasma dynamics can be used to provide additional insight PD activity.

1 April 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
GCGeorge Callender
George Callender
DEDaniel Ellis
Daniel Ellis
KGKevin F. Goddard
Kevin F. Goddard
JDJustin K. Dix
Justin K. Dix
JPJames A. Pilgrim
James A. Pilgrim
MEMatthias Erdmann
Matthias Erdmann
The ampacity of submarine cable circuits is strongly influenced by heat transfer in the marine environment surrounding the cable. It has been demonstrated in previous work that for high permeability sediments convective heat transfer can play a significant role using both bespoke two dimensional models and experimental investigations [1,2]. This paper introduces a one dimensional model which is capable of calculating cable temperatures within both convective and conductive sediments. Agreement between the one dimensional model and a two dimensional simulation was found to be within 1.5°C. The model is used to demonstrate that the ampacity of power cables may be significantly increased due to convective heat transfer. Further, the one dimensional model offers significant savings in computational time and cost compared to the two dimensional equivalent model. This allows the analysis of large DTS data sets in order to calculate: dynamic ratings; burial depths; and the long-term (annual to decadal) performance of the cable.

18 August 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ADAtip Doolgindachbaporn
Atip Doolgindachbaporn
GCGeorge Callender
George Callender
PLPaul Lewin
Paul Lewin
ESEdward Simonson
Edward Simonson
GWGordon Wilson
Gordon Wilson
The aim of this work is to develop a top-oil thermal model based on the thermal-electrical analogy and heat transfer principles that captures the thermal influence of prevailing winds and solar radiation which can be generally applied to large power transformers. The key improvements of the proposed thermal model are calculating the heat transfer coefficient of the radiator on the air side using the Nusselt number of combined forced and natural convection, and including the solar radiation as an addition heat source. The proposed model is validated with the operational measurements of 3 transformers that are comprised of a 120/240-MVA unit and two 90/180-MVA units. The results are also compared with the predictions based on the IEEE-Annex G model. The proposed model is more accurate over windy and summer periods as expected.

6 August 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
GCGeorge Callender
George Callender
KGKevin F. Goddard
Kevin F. Goddard
JDJustin K. Dix
Justin K. Dix
PLPaul Lewin
Paul Lewin
The ampacity of buried cables is significantly influenced by the thermal properties of the burial environment. When these thermal properties are not homogeneous it is usually necessary to utilize simulations with a relatively high computational cost that may also use commercial software. In this paper an alternative approach is proposed using conformal maps. Temperature is calculated in an annular domain which is a conformal mapping of the half plane space. Circumferential dependence is captured by expanding temperature as a Fourier series, a finite difference solver then determines temperature components radially. The model is as flexible as any two-dimensional slice model of heat transfer through thermal conduction only. Two case studies are considered: three land-based cables in planar configuration and a submarine export cable. The thermal properties of both burial environments are based on conditions which may be encountered in the field and exhibit a high level of stratification. Using a finite element analysis simulation as a benchmark, typical percentage differences in cable ampacities were 0.5%−1%. In addition to accuracy and flexibility the low computational cost of the proposed approach allows for large parameter sweeps, which may be required in a design phase, without requiring commercial software.