Yuanli Bai

Prof. Yuanli Bai

Associate Professor, Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2015 in International Journal of Fracture
Verified
Journal Article
Closed access
PDF file
YJYueqian Jia
Yueqian Jia
Yuanli BaiYuanli Bai
Yuanli Bai

1 May 2021 in Materialia
Verified
Journal Article
Closed access
HHHolden Hyer
Holden Hyer
LZLe Zhou
Le Zhou
QLQingyang Liu
Qingyang Liu
DWDazhong Wu
Dazhong Wu
SSShutao Song
Shutao Song
YSYongho Sohn
Yongho Sohn

1 May 2006 in International Journal of Impact Engineering
Verified
Journal Article
Closed access
Yuanli BaiYuanli Bai
Yuanli Bai
YBYingbin Bao
Yingbin Bao
TWTomasz Wierzbicki
Tomasz Wierzbicki


17 October 2019 in Metals
Verified
Journal Article
Open access
PDF file
MAMohammed Algarni
Mohammed Algarni
Yuanli BaiYuanli Bai
Yuanli Bai
MZMohammed Zwawi
Mohammed Zwawi
SGSami Ghazali
Sami Ghazali
This paper evaluates the damage evolution process under extremely low-cycle fatigue (ELCF). The study explores the damage behavior under different stress states. The influence of the multiaxial state of stress on the metal’s life is determined. Two different stress states were examined: (a) axisymmetric and (b) plane-strain. The study is based on the modified Mohr–Coulomb (MMC) ductile fracture criterion that was extended to cover the ELCF regime in a previous research study. Four distinctive geometries are designed to study the effect of different stress states on ELCF life and damage evolution. The damage model is calibrated for life prediction to agree with the ELCF experimental results. The investigation of the damage evolution behavior is dependent on equivalent plastic strain, stress triaxiality, Lode angle, and cyclic loading effect. The damage evolution is extracted from Abaqus finite element simulations and plotted versus the equivalent plastic strain. The damage accumulation shows nonlinear evolution behavior under cyclic loading conditions. SEM images were taken to further study the microscopic failure mechanisms of ELCF.

16 August 2017 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
YJYueqian Jia
Yueqian Jia
YQYangyang Qiao
Yangyang Qiao
IAI. Ricardo Argueta-Morales
I. Ricardo Argueta-Morales
AMAung Maung
Aung Maung
JNJack Norfleet
Jack Norfleet
WDWilliam M. DeCampli
William M. DeCampli
Homografts and synthetic grafts are used in surgery for congenital heart disease (CHD). Determining these materials' mechanical properties will aid in understanding tissue behavior when subjected to abnormal CHD hemodynamics. Homograft tissue samples from anterior/posterior aspects, of ascending/descending aorta (AA, DA), innominate artery (IA), left subclavian artery (LScA), left common carotid artery (LCCA), main/left/right pulmonary artery (MPA, LPA, RPA), and synthetic vascular grafts, were obtained in three orientations: circumferential, diagonal (45 deg relative to circumferential direction), and longitudinal. Samples were subjected to uniaxial tensile testing (UTT). True strain-Cauchy stress curves were individually fitted for each orientation to calibrate Fung model. Then, they were used to calibrate anisotropic Holzapfel–Gasser model (R2 > 0.95). Most samples demonstrated a nonlinear hyperelastic strain–stress response to UTT. Stiffness (measured by tangent modulus at different strains) in all orientations were compared and shown as contour plots. For each vessel segment at all strain levels, stiffness was not significantly different among aspects and orientations. For synthetic grafts, stiffness was significantly different among orientations (p < 0.042). Aorta is significantly stiffer than pulmonary artery at 10% strain, comparing all orientations, aspects, and regions (p = 0.0001). Synthetic grafts are significantly stiffer than aortic and pulmonary homografts at all strain levels (p < 0.046). Aortic, pulmonary artery, and synthetic grafts exhibit hyperelastic biomechanical behavior with anisotropic effect. Differences in mechanical properties among vascular grafts may affect native tissue behavior and ventricular/arterial mechanical coupling, and increase the risk of deformation due to abnormal CHD hemodynamics.