Xi Qin

Dr. Xi Qin

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2007 in Experimental and Molecular Pathology
Verified
Journal Article
Closed access
QXQianfeng Xia
Qianfeng Xia
SXSONGXIAO XU
SONGXIAO XU
DWDong-sheng Wang
Dong-sheng Wang
YWYang-An Wen
Yang-An Wen
XQXi Qin
Xi Qin
ZTZhi-Guang Tu
Zhi-Guang Tu

7 July 2020 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
XLXiang Li
Xiang Li
XSXinchang Shi
Xinchang Shi
XQXi Qin
Xi Qin
LYLei Yu
Lei Yu
YZYong Zhou
Yong Zhou
CRChunming Rao
Chunming Rao
Recombinant human erythropoietin (rhEPO) is one of the most important biopharmaceuticals worldwide, with global sales expected to reach US$11.9 billion in 2020.

22 June 2024 in Human Gene Therapy
Verified
Journal Article
Closed access
XQXi Qin
Xi Qin
QYQikun Yu
Qikun Yu
XLXiang Li
Xiang Li
WJWei Jiang
Wei Jiang
XSXinchang Shi
Xinchang Shi
CLChenggang Liang
Chenggang Liang
Currently, adeno-associated virus (AAV) is one of the primary gene delivery vectors in gene therapy, facilitating long-term in vivo gene expression. Despite being imperative, it is incredibly challenging to precisely assess AAV particle distribution according to the sedimentation coefficient and identify impurities related to capsid structures. This study performed the systematic methodological validation of quantifying the AAV empty and full capsid ratio. This includes specificity, accuracy, precision, linearity, and parameter variables involving the sedimentation velocity analytical ultracentrifugation (SV-AUC) method. Specifically, SV-AUC differentiated among the empty, partial, full, and high sedimentation coefficient substance (HSCS) AAV particles while evaluating their sedimentation heterogeneity. The intermediate precision analysis of HE (high percentage of empty capsid) and HF (high percentage of full capsid) samples revealed that the specific species percentage, such as empty or full, was more significant than 50%. Moreover, the relative standard deviation (RSD) could be within 5%. Even for empty or partially less than 15%, the RSD could be within 10%. The accuracy recovery rates of empty capsid were between 103.9% and 108.7% across three different mixtures. When the measured percentage of specific species was more significant than 14%, the recovery rate was between 77.9% and 106.6%. Linearity analysis revealed an excellent linear correlation between the empty, partial, and full in the HE samples. The AAV samples with as low as 7.4 × 10 11 cp/mL AAV could be accurately quantified with SV-AUC. The parameter variable analyses revealed that variations in cell alignment significantly affected the overall results. Still, the detection wavelength of 235 nm slightly influenced the empty, partial, and full percentages. Minor detection wavelength changes showed no impact on the sedimentation coefficient of these species. However, the temperature affected the measured sedimentation coefficient. These results validated the SV-AUC method to quantify AAV. This study provides solutions to AAV empty and full capsid ratio quantification challenges and the subsequent basis for calibrating the AAV empty capsid system suitability substance. Because of the AAV structure and potential variability complexity in detection, we jointly calibrated empty capsid system suitability substance with three laboratories to accurately detect the quantitative AAV empty and full capsid ratio. The empty capsid system suitability substance could be used as an external reference to measure the performance of the instrument. The results could be compared with multiple QC (quality control) laboratories based on the AAV vector and calibration accuracy. This is crucial for AUC to be used for QC release and promote gene therapy research worldwide.

9 April 2019 in Molecules
Verified
Journal Article
Open access
PDF file
WYWenrong Yao
Wenrong Yao
LYLei Yu
Lei Yu
WFWenhong Fan
Wenhong Fan
XSXinchang Shi
Xinchang Shi
LLLan Liu
Lan Liu
JWJunzhi Wang
Junzhi Wang
The long-acting growth hormone (LAGH) is a promising alternative biopharmaceutical to treat growth hormone (GH) deficiency in children, and it was developed using a variety of technologies by several pharmaceutical companies. Most LAGH preparations, such as Fc fusion protein, are currently undergoing preclinical study and clinical trials. Accurate determination of bioactivity is critical for the efficacy of quality control systems of LAGH. The current in vivo rat weight gain assays used to determine the bioactivity of recombinant human GH (rhGH) in pharmacopoeias are time-consuming, expensive, and imprecise, and there are no recommended bioassays for LAGH bioactivity in pharmacopoeias. Therefore, we developed a cell-based bioassay for bioactivity determination of therapeutic long-acting Fc-fusion recombinant human growth hormone (rhGH-Fc) based on the luciferase reporter gene system, which is involved in the full-length human GH receptor (hGHR) and the SG (SIE and GAS) response element. The established bioassay was comprehensively validated according to the International Council for Harmonization (ICH) Q2 (R1) guidelines and the Chinese Pharmacopoeia, and is highly precise, time-saving, simple, and robust. The validated bioassay could be qualified for bioactivity determination during the research, development, and manufacture of rhGH-Fc, and other LAGH formulations.

15 February 2019 in Molecules
Verified
Journal Article
Open access
PDF file
WYWenrong Yao
Wenrong Yao
YGYing Guo
Ying Guo
XQXi Qin
Xi Qin
LYLei Yu
Lei Yu
XSXinchang Shi
Xinchang Shi
JWJunzhi Wang
Junzhi Wang
The therapeutic recombinant human keratinocyte growth factor 1 (rhKGF-1) was approved by the FDA for oral mucositis resulting from hematopoietic stem cell transplantation for hematological malignancies in 2004. However, no recommended bioassay for rhKGF-1 bioactivity has been recorded in the U.S. Pharmacopoeia. In this study, we developed an rhKGF-1-dependent bioassay for determining rhKGF-1 bioactivity based on HEK293 and HaCat cell lines that stably expressed the luciferase reporter driven by the serum response element (SRE) and human fibroblast growth factor receptor (FGFR2) IIIb. A good responsiveness to rhKGF-1 and rhKGF-2 shared by target HEK293/HaCat cell lines was demonstrated. Our stringent validation was completely focused on specificity, linearity, accuracy, precision, and robustness according to the International Council for Harmonization (ICH) Q2 (R1) guidelines, AAPS/FDA Bioanalytical Workshop and the Chinese Pharmacopoeia. We confirmed the reliability of the method in determining rhKGF bioactivity. The validated method is highly timesaving, sensitive, and simple, and is especially valuable for providing information for quality control during the manufacture, research, and development of therapeutic rhKGF.

Verified
Journal Article
Open access
PDF file
GWGuangyu Wang
Guangyu Wang
QMQiang Ma
Qiang Ma
CWChanglong Wei
Changlong Wei
LYLei Yu
Lei Yu
HBHua Bi
Hua Bi
JWJun-Zhi Wang
Jun-Zhi Wang
Recombinant adeno-associated virus (rAAV) has emerged as a prominent vector for in vivo gene therapy, owing to its distinct advantages. Accurate determination of the rAAV genome titer is crucial for ensuring the safe and effective administration of clinical doses. The evolution of the rAAV genome titer assay from quantitative PCR (qPCR) to digital PCR (dPCR) has enhanced accuracy and precision, yet practical challenges persist. This study systematically investigated the impact of various operational factors on genome titration in a single-factor manner, aiming to address potential sources of variability in the quantitative determination process. Our findings revealed that a pretreatment procedure without genome extraction exhibits superior precision compared with titration with genome extraction. Additionally, notable variations in titration results across different brands of dPCR instruments were documented, with relative standard deviation (RSD) reaching 23.47% for AAV5 and 11.57% for AAV8. Notably, optimal operations about DNase I digestion were identified; we thought treatment time exceeding 30 min was necessary, and there was no need for thermal inactivation after digestion. And we highlighted that thermal capsid disruption before serial dilution substantially affected AAV genome titers, causing a greater than ten-fold decrease. Conversely, this study found that additive components of dilution buffer are not significant contributors to titration variations. Furthermore, we found that repeated freeze–thaw cycles significantly compromised AAV genome titers. In conclusion, a comprehensive dPCR titration protocol, incorporating insights from these impact factors, was proposed and successfully tested across multiple serotypes of AAV. The results demonstrate acceptable variations, with the RSD consistently below 5.00% for all tested AAV samples. This study provides valuable insights to reduce variability and improve the reproducibility of AAV genome titration using dPCR.