kathleen weyts

Dr. kathleen weyts

Centre François Baclesse, Caen, Normandie, France
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2022 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
KWkathleen weyts
kathleen weyts
CLCharline Lasnon
Charline Lasnon
RCRenaud Ciappuccini
Renaud Ciappuccini
JLJustine LEQUESNE
Justine LEQUESNE
ACAurélien Corroyer-Dulmont
Aurélien Corroyer-Dulmont
CJCyril Jaudet
Cyril Jaudet
Purpose: We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. Methods: One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original “PET90” (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, “PET45AI and PET45”. Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. Results: PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). Conclusion: AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.

1 July 2021 in Radiology
Verified
Journal Article
Closed access
EQElske Quak
Elske Quak
GGGilles Girault
Gilles Girault
MTMarie Aude Thenint
Marie Aude Thenint
KWkathleen weyts
kathleen weyts
JLJustine LEQUESNE
Justine LEQUESNE
CLCharline Lasnon
Charline Lasnon
Background Early reports show the unequal effect the COVID-19 pandemic might have on men versus women engaged in medical research. Purpose To investigate whether the COVID-19 pandemic has ...

24 August 2021 in Frontiers in Oncology
Verified
Journal Article
Open access
CJCyril Jaudet
Cyril Jaudet
KWkathleen weyts
kathleen weyts
ALAlexis Lechervy
Alexis Lechervy
ABAlain Batalla
Alain Batalla
SBStéphane Bardet
Stéphane Bardet
ACAurélien Corroyer-Dulmont
Aurélien Corroyer-Dulmont
Background: With a constantly increasing number of diagnostic images performed each year, Artificial Intelligence (AI) denoising methods offer an opportunity to respond to the growing demand. However, it may affect information in the image in an unknown manner. This study quantifies the effect of AI-based denoising on FDG PET textural information in comparison to a convolution with a standard gaussian postfilter (EARL1).Methods: The study was carried out on 113 patients who underwent a digital FDG PET/CT (VEREOS, Philips Healthcare). 101 FDG avid lesions were segmented semi-automatically by a nuclear medicine physician. VOIs in the liver and lung as reference organs were contoured. PET textural features were extracted with pyradiomics. Texture features from AI denoised and EARL1 versus original PET images were compared with a Concordance Correlation Coefficient (CCC). Features with CCC values ≥ 0.85 threshold were considered concordant. Scatter plots of variable pairs with R2 coefficients of the more relevant features were computed. A Wilcoxon signed rank test to compare the absolute values between AI denoised and original images was performed.Results: The ratio of concordant features was 90/104 (86.5%) in AI denoised versus 46/104 (44.2%) with EARL1 denoising. In the reference organs, the concordant ratio for AI and EARL1 denoised images was low, respectively 12/104 (11.5%) and 7/104 (6.7%) in the liver, 26/104 (25%) and 24/104 (23.1%) in the lung. SUVpeak was stable after the application of both algorithms in comparison to SUVmax. Scatter plots of variable pairs showed that AI filtering affected more lower versus high intensity regions unlike EARL1 gaussian post filters, affecting both in a similar way. In lesions, the majority of texture features 79/100 (79%) were significantly (p<0.05) different between AI denoised and original PET images.Conclusions: Applying an AI-based denoising on FDG PET images maintains most of the lesion’s texture information in contrast to EARL1-compatible Gaussian filter. Predictive features of a trained model could be thus the same, however with an adapted threshold. Artificial intelligence based denoising in PET is a very promising approach as it adapts the denoising in function of the tissue type, preserving information where it should.

24 August 2021 in Frontiers in Oncology
Verified
Journal Article
Open access
ACAurélien Corroyer-Dulmont
Aurélien Corroyer-Dulmont
CJCyril Jaudet
Cyril Jaudet
AFAnne-Marie Frelin
Anne-Marie Frelin
JFJade Fantin
Jade Fantin
KWkathleen weyts
kathleen weyts
SVSamuel Valable
Samuel Valable
Brain metastases (BM) are frequently detected during the follow-up of patients with malignant tumors, particularly in those with advanced disease. Despite a major progress in systemic anti-cancer treatments, the average overall survival of these patients remains limited (6 months from diagnosis). Also, cognitive decline is regularly reported especially in patients treated with whole brain external beam radiotherapy (WBRT), due to the absorbed radiation dose in healthy brain tissue. New targeted therapies, for an earlier and/or more specific treatment of the tumor and its microenvironment, are needed. Radioimmunotherapy (RIT), a combination of a radionuclide to a specific antibody, appears to be a promising tool. Inflammation, which is involved in multiple steps, including the early phase, of BM development is attractive as a relevant target for RIT. This review will focus on the (1) early biomarkers of inflammation in BM pertinent for RIT, (2) state of the art studies on RIT for BM, and (3) the importance of dosimetry to RIT in BM. These two last points will be addressed in comparison to the conventional EBRT treatment, particularly with respect to the balance between tumor control and healthy tissue complications. Finally, because new diagnostic imaging techniques show a potential for the detection of BM at an early stage of the disease, we focus particularly on this therapeutic window.

1 September 2017 in Clinical Imaging
Verified
Journal Article
Closed access
KWkathleen weyts
kathleen weyts
MVMeike Vernooij
Meike Vernooij
RSRebecca Steketee
Rebecca Steketee
RVRoelf Valkema
Roelf Valkema
MSMarion Smits
Marion Smits

10 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
NANicolas Aide
Nicolas Aide
KWkathleen weyts
kathleen weyts
CLCharline Lasnon
Charline Lasnon
This study aimed to investigate if combining clinical characteristics with pre-therapeutic 18 F-fluorodeoxyglucose (18 F-FDG) positron emission tomography (PET) radiomics could predict the presence of molecular alteration(s) in key molecular targets in lung adenocarcinoma. This non-interventional monocentric study included patients with newly diagnosed lung adenocarcinoma referred for baseline PET who had tumour molecular analyses. The data were randomly split into training and test datasets. LASSO regression with 100-fold cross-validation was performed, including sex, age, smoking history, AJCC cancer stage and 31 PET variables. In total, 109 patients were analysed, and it was found that 63 (57.8%) patients had at least one molecular alteration. Using the training dataset (n = 87), the model included 10 variables, namely age, sex, smoking history, AJCC stage, excessKustosis_HISTO, sphericity_SHAPE, variance_GLCM, correlation_GLCM, LZE_GLZLM, and GLNU_GLZLM. The ROC analysis for molecular alteration prediction using this model found an AUC equal to 0.866 (p < 0.0001). A cut-off value set to 0.48 led to a sensitivity of 90.6% and a positive likelihood ratio (LR+) value equal to 2.4. After application of this cut-off value in the unseen test dataset of patients (n = 22), the test presented a sensitivity equal to 90.0% and an LR+ value of 1.35. A clinico-metabolic 18 F-FDG PET phenotype allows the detection of key molecular target alterations with high sensitivity and negative predictive value. Hence, it opens the way to the selection of patients for molecular analysis.