Timur Tenchurin

Dr. Timur Tenchurin


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
Ilya D. KlabukovIlya D. Klabukov
Ilya D. Klabukov
TTTimur Tenchurin
Timur Tenchurin
ASAlexey Shepelev
Alexey Shepelev
DBDenis Baranovskii
Denis Baranovskii
VMVissarion Mamagulashvili
Vissarion Mamagulashvili
SCSergei N. Chvalun
Sergei N. Chvalun
This article reports the electrospinning technique for the manufacturing of multilayered scaffolds for bile duct tissue engineering based on an inner layer of polycaprolactone (PCL) and an outer layer either of a copolymer of D,L-lactide and glycolide (PLGA) or a copolymer of L-lactide and ε-caprolactone (PLCL). A study of the degradation properties of separate polymers showed that flat PCL samples exhibited the highest resistance to hydrolysis in comparison with PLGA and PLCL. Irrespective of the liquid-phase nature, no significant mass loss of PCL samples was found in 140 days of incubation. The PLCL- and PLGA-based flat samples were more prone to hydrolysis within the same period of time, which was confirmed by the increased loss of mass and a significant reduction of weight-average molecular mass. The study of the mechanical properties of developed multi-layered tubular scaffolds revealed that their strength in the longitudinal and transverse directions was comparable with the values measured for a decellularized bile duct. The strength of three-layered scaffolds declined significantly because of the active degradation of the outer layer made of PLGA. The strength of scaffolds with the PLCL outer layer deteriorated much less with time, both in the axial (p-value = 0.0016) and radial (p-value = 0.0022) directions. A novel method for assessment of the physiological relevance of synthetic scaffolds was developed and named the phase space approach for assessment of physiological relevance. Two-dimensional phase space (elongation modulus and tensile strength) was used for the assessment and visualization of the physiological relevance of scaffolds for bile duct bioengineering. In conclusion, the design of scaffolds for the creation of physiologically relevant tissue-engineered bile ducts should be based not only on biodegradation properties but also on the biomechanical time-related behavior of various compositions of polymers and copolymers.

21 March 2019 in Cell Proliferation
Verified
Journal Article
Open access
PDF file
OROlga A. Romanova
Olga A. Romanova
TTTimur Tenchurin
Timur Tenchurin
Tatiana S. DeminaTatiana S. Demina
Tatiana S. Demina
ESElena V. Sytina
Elena V. Sytina
ASAlexey D. Shepelev
Alexey D. Shepelev
APAndrey Panteleyev
Andrey Panteleyev
Objectives: The conversion of tissue engineering into a routine clinical tool cannot be achieved without a deep understanding of the interaction between cells and scaffolds during the process of tissue formation in an artificial environment. Here, we have investigated the cultivation conditions and structural features of the biodegradable non‐woven material in order to obtain a well‐differentiated human airway epithelium.Materials and methods: The bilayered scaffold was fabricated by electrospinning technology. The efficiency of the scaffold has been evaluated using MTT cell proliferation assay, histology, immunofluorescence and electron microscopy.Results: With the use of a copolymer of chitosan‐gelatin‐poly‐l‐lactide, a bilayered non‐woven scaffold was generated and characterized. The optimal structural parameters of both layers for cell proliferation and differentiation were determined. The basal airway epithelial cells differentiated into ciliary and goblet cells and formed pseudostratified epithelial layer on the surface of the scaffold. In addition, keratinocytes formed a skin equivalent when seeded on the same scaffold. A comparative analysis of growth and differentiation for both types of epithelium was performed.Conclusions: The structural parameters of nanofibres should be selected experimentally depending on polymer composition. The major challenges on the way to obtain the well‐differentiated equivalent of respiratory epithelium on non‐woven scaffold include the following: the balance between scaffold permeability and thickness, proper combination of synthetic and natural components, and culture conditions sufficient for co‐culturing of airway epithelial cells and fibroblasts. For generation of skin equivalent, the lack of diffusion is not so critical as for pseudostratified airway epithelium.

30 March 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
MZMargarita Zhuravleva
Margarita Zhuravleva
ZGZarema Gilazieva
Zarema Gilazieva
TGTimofei Grigoriev
Timofei Grigoriev
ASAlexey D. Shepelev
Alexey D. Shepelev
TTTimur Tenchurin
Timur Tenchurin
PMPaolo Macchiarini
Paolo Macchiarini

Verified
Journal Article
Open access
PDF file
Ilya D. KlabukovIlya D. Klabukov
Ilya D. Klabukov
MBMaxim Balyasin
Maxim Balyasin
OKOlga Krasilnikova
Olga Krasilnikova
TTTimur Tenchurin
Timur Tenchurin
ATAlexander Titov
Alexander Titov
AKAndrei Kaprin
Andrei Kaprin
Insufficient vascular growth in the area of artificial-material implantation contributes to ischemia, fibrosis, the development of bacterial infections, and tissue necrosis around the graft. The purpose of this study was to evaluate angiogenesis after implantation of polycaprolactone microfiber scaffolds modified by a pCMV-VEGF165-plasmid in rats. Influence of vascularization on scaffold degradation was also examined. We investigated flat microfibrous scaffolds obtained by electrospinning polycaprolactone with incorporation of the pCMV-VEGF-165 plasmid into the microfibers at concentrations of 0.005 ng of plasmid per 1 mg of polycaprolactone (0.005 ng/mg) (LCGroup) and 0.05 ng/mg (HCGroup). The samples were subcutaneously implanted in the interscapular area of rats. On days 7, 16, 33, 46, and 64, the scaffolds were removed, and a histological study with a morphometric evaluation of the density and diameter of the vessels and microfiber diameter was performed. The number of vessels was increased in all groups, as well as the resorption of the scaffold. On day 33, the vascular density in the HCGroup was 42% higher compared to the control group (p = 0.0344). The dose-dependent effect of the pCMV-VEGF165-plasmid was confirmed by enhanced angiogenesis in the HCGroup compared to the LCGroup on day 33 (p-value = 0.0259). We did not find a statistically significant correlation between scaffold degradation rate and vessel growth (the Pearson correlation coefficient was ρ = 0.20, p-value = 0.6134). Functionalization of polycaprolactone by incorporation of the pCMV-VEGF165 plasmid provided improved vascularization within 33 days after implantation, however, vessel growth did not seem to correlate with scaffold degradation rate.

15 October 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
LSLiubov Safonova
Liubov Safonova
MBMaria Bobrova
Maria Bobrova
AEAnton E. Efimov
Anton E. Efimov
AEAnton E. Efimov
Anton E. Efimov
TTTimur Tenchurin
Timur Tenchurin
IAIgor I. Agapov
Igor I. Agapov
The main goal of our research was to fabricate electrospun scaffolds from three different silk proteins—silk fibroin from Bombyx mori silkworm cocoons and two recombinant spidroins, rS2/12 and rS2/12-RGDS—and to perform a comparative analysis of the structure, biological properties, and regenerative potential of the scaffolds in a full-thickness rat skin wound model. The surface and internal structures were investigated using scanning electron microscopy and scanning probe nanotomography. The structures of the scaffolds were similar. The average fiber diameter of the scaffolds was 315 ± 26 nm, the volume porosity was 94.5 ± 1.4%, the surface-to-volume ratio of the scaffolds was 25.4 ± 4.2 μm−1 and the fiber surface roughness was 3.8 ± 0.6 nm. The scaffolds were characterized by a non-cytotoxicity effect and a high level of cytocompatibility with cells. The scaffolds also had high regenerative potential—the healing of the skin wound was accelerated by 19 days compared with the control. A histological analysis did not reveal any fragments of the experimental constructions or areas of inflammation. Thus, novel data on the structure and biological properties of the silk fibroin/spidroin electrospun scaffolds were obtained.

1 September 2014 in Fibre Chemistry
Verified
Journal Article
Closed access
PDF file
TTTimur Tenchurin
Timur Tenchurin
SKS. N. Krasheninnikov
S. N. Krasheninnikov
AOA. S. Orekhov
A. S. Orekhov
SCSergei N. Chvalun
Sergei N. Chvalun
ASA. D. Shepelev
A. D. Shepelev
AGA. I. Gulyaev
A. I. Gulyaev