Hiroto Takahashi

Dr. Hiroto Takahashi


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in European Journal of Radiology
Verified
Journal Article
Closed access
HTHiroto Takahashi
Hiroto Takahashi
YWY. Watanabe
Y. Watanabe
HTH. Tanaka
H. Tanaka
MMM. Mihara
M. Mihara
HMH. Mochizuki
H. Mochizuki
NTN. Tomiyama
N. Tomiyama

21 November 2013 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HTHiroto Takahashi
Hiroto Takahashi
KIK. Ishii
K. Ishii
CHC. Hosokawa
C. Hosokawa
THT. Hyodo
T. Hyodo
NKN. Kashiwagi
N. Kashiwagi
TMT. Murakami
T. Murakami
BACKGROUND AND PURPOSE: Alzheimer disease is the most common neurodegenerative disorder with dementia, and a practical and economic biomarker for diagnosis of Alzheimer disease is needed. Three-dimensional arterial spin-labeling, with its high signal-to-noise ratio, enables measurement of cerebral blood flow precisely without any extrinsic tracers. We evaluated the performance of 3D arterial spin-labeling compared with SPECT, and demonstrated the 3D arterial spin-labeled imaging characteristics in the diagnosis of Alzheimer disease. MATERIALS AND METHODS: This study included 68 patients with clinically suspected Alzheimer disease who underwent both 3D arterial spin-labeling and SPECT imaging. Two readers independently assessed both images. Kendall W coefficients of concordance (K) were computed, and receiver operating characteristic analyses were performed for each reader. The differences between the images in regional perfusion distribution were evaluated by means of statistical parametric mapping, and the incidence of hypoperfusion of the cerebral watershed area, referred to as “borderzone sign” in the 3D arterial spin-labeled images, was determined. RESULTS: Readers showed K = 0.82/0.73 for SPECT/3D arterial spin-labeled imaging, and the respective areas under the receiver operating characteristic curve were 0.82/0.69 for reader 1 and 0.80/0.69 for reader 2. Statistical parametric mapping showed that the perisylvian and medial parieto-occipital perfusion in the arterial spin-labeled images was significantly higher than that in the SPECT images. Borderzone sign was observed on 3D arterial spin-labeling in 70% of patients misdiagnosed with Alzheimer disease. CONCLUSIONS: The diagnostic performance of 3D arterial spin-labeling and SPECT for Alzheimer disease was almost equivalent. Three-dimensional arterial spin-labeled imaging was more influenced by hemodynamic factors than was SPECT imaging.

6 October 2020 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
YWYoshiyuki Watanabe
Yoshiyuki Watanabe
TTTakahiro Tanaka
Takahiro Tanaka
ANAtsushi Nishida
Atsushi Nishida
HTHiroto Takahashi
Hiroto Takahashi
MFMasahiro Fujiwara
Masahiro Fujiwara
KYKazuhisa Yoshiya
Kazuhisa Yoshiya

26 November 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
HTHiroto Takahashi
Hiroto Takahashi
NKNobuo Kashiwagi
Nobuo Kashiwagi
AAAtsuko Arisawa
Atsuko Arisawa
CMChisato Matsuo
Chisato Matsuo
HKHiroki Kato
Hiroki Kato
NTNoriyuki Tomiyama
Noriyuki Tomiyama
Objective: To assess the utility of examining the nigrostriatal system with MRI and dopamine transporter (DAT) imaging for evaluating the preclinical phase of Parkinson’s disease (PD). Methods: The subjects were 32 patients with early PD and a history of probable rapid eye movement sleep behavior disorder (RBD; PD group), 15 patients with idiopathic RBD (RBD group), and 24 age-matched healthy controls (HC group) who underwent neuromelanin and diffusion tensor MRI for analysis of the substantia nigra pars compacta (SNpc). The RBD and PD groups underwent DAT imaging. In the RBD group, totals of 39 MRI and 27 DAT imaging examinations were obtained longitudinally. For each value, intergroup differences and receiver operating characteristic analysis for diagnostic performance were examined statistically. Results: The neuromelanin value was significantly lower and the diffusion tensor values except fractional anisotropy were significantly higher in the RBD and PD groups than in the HC group. The DAT specific binding ratio (SBR) was significantly lower in the PD group than in the RBD group. The areas under the receiver operating characteristic curves (AUCs) for neuromelanin/mean diffusivity value in the SNpc were 0.76/0.82 for diagnosing RBD and 0.83/0.80 for diagnosing PD. The area under the receiver operating characteristic curves for the SBR for discriminating PD from RBD was 0.87. Conclusion: MRI and DAT imaging may be useful for evaluating sequential nigrostriatal changes during the preclinical phase of PD. Advances in knowledge: MRI detects nigrostriatal changes in both RBD and early PD, and DAT imaging detects nigrostriatal changes during the transition to PD in RBD.

1 February 2017 in Clinical Radiology
Verified
Journal Article
Closed access
HTHiroto Takahashi
Hiroto Takahashi
KIK. Ishii
K. Ishii
NKN. Kashiwagi
N. Kashiwagi
YWY. Watanabe
Y. Watanabe
HTH. Tanaka
H. Tanaka
NTN. Tomiyama
N. Tomiyama

1 April 2013 in The Veterinary Journal
Verified
Journal Article
Closed access
FMFumie Magata
Fumie Magata
DHDesiree Hartmann
Desiree Hartmann
MIMitsuo Ishii
Mitsuo Ishii
RMRyotaro Miura
Ryotaro Miura
HTHiroto Takahashi
Hiroto Takahashi
HBHeinrich Bollwein
Heinrich Bollwein