6 October 2020 in Neuroradiology
1 January 2022 in Journal Of Neuroradiology
29 November 2021 in Acta Radiologica Open
Recognition of the anatomical course of the chorda tympani nerve (CTN) is important for preventing iatrogenic injuries during middle-ear surgery. This study aims to compare visualization of the CTN using two computed tomography (CT) methods: conventional high-resolution CT (C-HRCT) and ultra‐high-resolution CT (U-HRCT). We performed a retrospective visual assessment of 59 CTNs in normal temporal bones of 54 consecutive patients who underwent both C-HRCT and U-HRCT. After dividing CTN into three anatomical segments (posterior canaliculus, tympanic segment, and anterior canaliculus), two neuroradiologists scored the visualizations on a four-point scale. On C-HRCT, the visual scores of the posterior canaliculus, tympanic segment, and anterior canaliculus were 3.5 ± 0.7, 1.6 ± 0.6, and 3.1 ± 0.7, respectively. The respective values were significantly higher in all segments on U-HRCT: 3.9 ± 0.2, 2.4 ± 0.6, 3.5 ± 0.6 (p < 0.01). Although the difference in scores between methods was greatest for the tympanic segment, the visual score on U-HRCT was lower for the tympanic segment than for the anterior and posterior segments (p < 0.01). Ultra‐high-resolution CT provides superior visualization of the CTN, especially the tympanic segment.
29 March 2024 in Japanese Journal of Radiology
Purpose: To propose a five-point scale for radiology report importance called Report Importance Category (RIC) and to compare the performance of natural language processing (NLP) algorithms in assessing RIC using head computed tomography (CT) reports written in Japanese. Materials and methods: 3728 Japanese head CT reports performed at Osaka University Hospital in 2020 were included. RIC (category 0: no findings, category 1: minor findings, category 2: routine follow-up, category 3: careful follow-up, and category 4: examination or therapy) was established based not only on patient severity but also on the novelty of the information. The manual assessment of RIC for the reports was performed under the consensus of two out of four neuroradiologists. The performance of four NLP models for classifying RIC was compared using fivefold cross-validation: logistic regression, bidirectional long–short-term memory (BiLSTM), general bidirectional encoder representations of transformers (general BERT), and domain-specific BERT (BERT for medical domain). Results: The proportion of each RIC in the whole data set was 15.0%, 26.7%, 44.2%, 7.7%, and 6.4%, respectively. Domain-specific BERT showed the highest accuracy (0.8434 ± 0.0063) in assessing RIC and significantly higher AUC in categories 1 (0.9813 ± 0.0011), 2 (0.9492 ± 0.0045), 3 (0.9637 ± 0.0050), and 4 (0.9548 ± 0.0074) than the other models (p < .05). Analysis using layer-integrated gradients showed that the domain-specific BERT model could detect important words, such as disease names in reports. Conclusions: Domain-specific BERT has superiority over the other models in assessing our newly proposed criteria called RIC of head CT radiology reports. The accumulation of similar and further studies of has a potential to contribute to medical safety by preventing missed important findings by clinicians.
8 January 2025 in International Journal of Computer Assisted Radiology and Surgery
Purpose: Systems equipped with natural language (NLP) processing can reduce missed radiological findings by physicians, but the annotation costs are burden in the development. This study aimed to compare the effects of active learning (AL) algorithms in NLP for estimating the significance of head computed tomography (CT) reports using bidirectional encoder representations from transformers (BERT). Methods: A total of 3728 head CT reports annotated with five categories of importance were used and UTH-BERT was adopted as the pre-trained BERT model. We assumed that 64% (2385 reports) of the data were initially in the unlabeled data pool (UDP), while the labeled data set (LD) used to train the model was empty. Twenty-five reports were repeatedly selected from the UDP and added to the LD, based on seven metrices: random sampling (RS: control), four uncertainty sampling (US) methods (least confidence (LC), margin sampling (MS), ratio of confidence (RC), and entropy sampling (ES)), and two distance-based sampling (DS) methods (cosine distance (CD) and Euclidian distance (ED)). The transition of accuracy of the model was evaluated using the test dataset. Results: The accuracy of the models with US was significantly higher than RS when reports in LD were < 1800, whereas DS methods were significantly lower than RS. Among the US methods, MS and RC were even better than the others. With the US methods, the required labeled data decreased by 15.4–40.5%, and most efficient in RC. In addition, in the US methods, data for minor categories tended to be added to LD earlier than RS and DS. Conclusions: In the classification task for the importance of head CT reports, US methods, especially RC and MS can lead to the effective fine-tuning of BERT models and reduce the imbalance of categories. AL can contribute to other studies on larger datasets by providing effective annotation.