Widandi Soetopo

Dr. Widandi Soetopo


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Journal of Water and Land Development
Verified
Journal Article
Open access
PDF file
NSNugroho Suryoputro
Nugroho Suryoputro
SUSuhardjono
Suhardjono
WSWidandi Soetopo
Widandi Soetopo
ESEry S. Suhartanto
Ery S. Suhartanto
LLLily Montarcih Limantara
Lily Montarcih Limantara
The aims of this study were to evaluate five infiltration models for mineral soils in the tropics with different land use types, such as settlements, plantations, rice fields, and forests. The infiltration models evaluated were Green–Ampt, Kostiakov, Kostiakov–Lewis, Philip, and Horton. The research was conducted at the Amprong watershed, Malang, Indonesia. The infiltration rate of the thirteen soil samples was analysed. The infiltration was tested using Turf-Tech infiltrometer. Moreover, each soil sample was tested in terms of the bulk density, specific gravity, porosity, soil moisture, and soil texture. The results of the study indicate that there is no significant difference (α = 5%) in the infiltration rate among the five models of infiltration. The infiltration rate in the study site was considered fast. Three models exhibiting the best performance are Kostiakov, Kostiakov–Lewis, and Horton model, respectively. The highest infiltration rate occurred in the forest land use while the lowest occurred in the rice field land use. The results of this study suggest that the infiltration model parameters correlate closely with the initial infiltration rate (fo) and the final infiltration rate (fc). In other words there is a correlation between the soil's ability to absorb water (representing the capillary force or horizontal flow) at the beginning of the infiltration (fo) and the gravity or the vertical flow upon reaching the final infiltration rate (fc).

15 November 2018 in Environmental Research, Engineering and Management
Verified
Journal Article
Closed access
PDF file
NSNugroho Suryoputro
Nugroho Suryoputro
WSWidandi Soetopo
Widandi Soetopo
ESEry Suhartanto
Ery Suhartanto
LLLily Montarcih Limantara
Lily Montarcih Limantara
SUSugeng Utaya
Sugeng Utaya
SUSuhardjono
Suhardjono
This research aimed at developing a conceptual hydrological model (tank model) with interception and root uptake. It was conducted in a sub-watershed of Coban Rondo located in an area with 89% forest and plantation land. 10-year rainfall and discharge data were used to perform calibration, verification and simulation. The calibration utilised a hybrid optimisation method of random search and genetic algorithm. A water balance equation was developed. The effect of interception and root uptake parameters on the modelling procedure was evaluated using the Nash-Sutcliffe Efficiency (NSE) coefficient and paired sample t-test. Results showed that, at a significance level of 5%, the interception and root uptake parameters had a significant effect on modelling (t Stat = 8.457 > t Critical two-tail = 1.980). The modelling performance increased by 26.98% with a NSE value of 0.91.DOI: http://dx.doi.org/10.5755/j01.erem.74.3.21154

2 August 2025 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
VPVena Rahayu Surya Putra
Vena Rahayu Surya Putra
MBMohammad Bisri
Mohammad Bisri
WSWidandi Soetopo
Widandi Soetopo
MSMoh Sholichin
Moh Sholichin
This research investigates the effectiveness of tertiary boxes in irrigation systems by optimizing structural functions, combining overflow and orifice mechanisms to achieve more accurate water distribution. Designs incorporating overflow and orifice can achieve more balanced water allocation under various flow conditions. The discharge coefficient (Cd) is measured due to variations in orifice number and diameter, and in the sharp-crested weir width. The results show that the discharge coefficient (Cd) changes with variations in the width of the sharp-crested weir, indicating an accumulation or fluctuation along the weir width, diameter of orifice, and number of orifices. The optimal configuration between the discharge coefficient and the sharp-crested weir for sharp-crested weir widths of 0.33 m and 0.42 m was found, using 3 orifices, each with a diameter of 4 cm. The discharge coefficient over the sharp-crested weir for the width of 0.33 m uses the formula, Cd = 0.7384 (h1/p)-0.094 for Channel-1 and Cd = 0.3294 × (h1/p)-0.296, for Channel-2 and 3. The discharge coefficient on orifice uses the formula, Cd = 0.482 × (h1/d)-0.0709, for Channel-1 and Cd = 0.3765 × (h1/d) × 0.1751, for Channel-2 and 3. However, the discharge coefficient over the sharp-crested weir for the width of 0.42 m uses the formula, Cd = 0.8215 × (h1/p)-0.058, for Channel-1 and Cd = 0.3202 × (h1/p)-0.286, for Channel-2 and 3, the discharge coefficient on orifice uses the formula, Cd = 0.3469 × (h1/d) × 0.2651, for Channel-1 and Cd = 0.177 × (h1/d) × 0.614 for Channel-2 and 3.

1 March 2018 in Journal of Water and Land Development
Verified
Journal Article
Open access
PDF file
WSWidandi Soetopo
Widandi Soetopo
SUSuhardjono
Suhardjono
UAUssy Andawayanti
Ussy Andawayanti
RSRini Wahyu Sayekti
Rini Wahyu Sayekti
JIJanu Ismoyo
Janu Ismoyo
Three models of release rule for operating a large reservoir for irrigation water supply are discussed in this paper. The models are a 50-grid storage continuous line restricted release rule, a single rule curve release rule, and a multi 4 rule curves release rule. These three models are to be optimized by stochastic simulation using 30 year inflow data with the maximization of the average monetary annual production in the irrigation area as the objective function. The purpose of this study is to look for the proper release rule for operating the Sutami Reservoir. The optimization is done first by the random search stochastic simulation model to generate a number of alternative solutions. Using these solutions as a generation of solutions, the genetic algorithm model is the applied to improve the solution. Afterward the best of solutions are checked by the Add-Ins Solver of MS-Excel 2010 to see if they can still be improved further. The results show that the 4 rule curves model gives the best solution with the average monetary annual production in the irrigation area of USD 72.248 million.

4 February 2021 in Jurnal Teknologi dan Rekayasa Sumber Daya Air
Verified
Journal Article
Open access
PDF file
TLTania Chrisna Maria Lake
Tania Chrisna Maria Lake
RSRini Wahyu Sayekti
Rini Wahyu Sayekti
WSWidandi Soetopo
Widandi Soetopo
The Bena Irrigation Area has 68 tertiary blocks where the total area of rice fields is 3515 ha with a length of 23 km. However, the Bena Irrigation Area experiences water deficits annually, particularly during the dry season. The phenomenon mentioned causes inefficiency from the functional point of view of The Bena Dam, which only irrigates 2470 Hectares of rice fields effectively. The phenomenon mentioned causes inefficiency from the functional point of view of The Bena Dam, which only irrigates 3515 Hectares of rice fields effectively. This thesis is discussing the simulation of water supply irrigation based on the Water Use Index (IPA) method. The purpose of the simulation is to overcome the water shortage at the Bena Irrigation Area by obtaining the ideal and/or most efficient volume of water by using the Water Use Index (IPA). Referring to the simulation presented with the IPA value at 0,5 hypothetically (good criteria), it revealed that the greatest volume is at 239,067 lt/sec at the first planting season, 862,948 lt/sec in the second planting season, and 39,571 lt/sec simultaneously. Daerah Irigasi Bena mempunyai petak tersier sebanyak 68 petak dimana luas total baku sawah 3515 ha dengan panjang 23 km. Namun, Daerah Irigasi Bena mengalami peningkatan kekurangan dan kekeringan air di setiap tahunnya terutama pada saat musim kemarau. Hal ini menyebakan Bendung Bena yang harusnya mengairi sawah seluas 3515 Ha hanya mampu mengairi sawah fungsional seluas 2470 Ha. Oleh karena itu, perlu adanya simulasi pemberian air irigasi untuk mengatasi kekurangan air yang terjadi di Daerah Irigasi Bena. Salah satu cara untuk mensimulasi penyediaan air irigasi menggunakan metode indeks penggunaan air (IPA). Tujuan dari simulasi pemberian air dengan nilai indeks penggunaan air (IPA) agar memperoleh hasil dari menghemat air irigasi yang paling hemat sehingga dapat mengatasi kekurangan air yang terjadi. Berdasarkan hasil simulasi nilai IPA diperoleh hasil dengan coba-coba nilai IPA = 0,5 (kriteria baik) mempunyai nilai paling besar adalah 862,948 lt/detik (musim tanam II) , 239,067 (musim tanam I), dan 39,571 lt/dtk (musim tanam III).

27 January 2021 in Jurnal Teknologi dan Rekayasa Sumber Daya Air
Verified
Journal Article
Open access
PDF file
RRRatu Anita Rachmawati
Ratu Anita Rachmawati
WSWidandi Soetopo
Widandi Soetopo
PJPitojo Tri Juwono
Pitojo Tri Juwono
Perkembangan Kabupaten Kuningan dari tahun ke tahun semakin pesat sehingga menyebababkan turut pesatnya kebutuhan air penduduknya. Pembangunan Waduk Kunigan diharapkan bisa mencukupi kebutuhan air penduduk Kabupaten Kuningan. Pada penelitian ini melihat besarnya kebutuhan air maka perlu adanya optimasi guna memenuhi kebutuhan air yang diperlukan dan metode optimasi yang dipilih adalah Algoritma Genetik. Mode ini dijalankan dengan spreadsheet Excel dari Microsoft Office versi 2007. Menurut hasil analisis, Pusat tahapan optimasi dengan Algoritma genetik pada struktur daripada kromosom. Kromosom dalam hal ini adalah aturan lepasan waduk yang mewakili alternatif solusi, jadi kromosom ini bisa dikatakan interfal lepasan waduk yang bermacam macam variasinya & mempunyai nilai kinerja Menurut fungsi tujuan. Setelah dilakukan optimasi, rata-rata kebutuhan air meningkat 63,83%, dan kebutuhan air minimal meningkat 44,57%. Keadaan tampungan waduk minimal 2,55 juta meter kubik, dan kapasitas tampungan air rata-rata 17,01 juta meter kubik. Rata-rata energi yang dihasilkan PLTA meningkat 14,72%, dan energi minimum yang dihasilkan PLTA meningkat 72,53%. Sehingga dapat memaksimalkan kinerja reservoir tanpa mengalami kerusakan. Hal ini diharapkan dapat memberikan acuan untuk pedoman lepasan teroptimal pada pengoperasiannya waduk Kuningan agar keperluan irigasi, air baku, dan PLTA terpenuhi The development of Kuningan Regency from year to year is increasing rapidly, causing the rapid need for water for its population. It is hoped that the Kunigan Reservoir construction can meet the water needs of the residents of Kuningan Regency. In this study, seeing the amount of water demand, it is necessary to optimize it to meet the required water needs and the chosen optimization method is the Genetic Algorithm. This mode is run with Excel spreadsheets from Microsoft Office 2007 version. Based of the analysis results, the optimization phase centers with genetic algorithms on the structure rather than chromosomes. The chromosome in this case is the reservoir discharge rule that represents an alternative solution, so this chromosome can be said to be the interface discharge of the reservoir which has various variations and has a performance value based on the objective function. After optimization, the average water demand increased by 63.83%, and the minimum water requirement increased by 44.57%. The condition of the reservoir is at least 2.55 m3, and the average storage capacity is 17.01 m3. The average energy produced by PLTA increased by 14.72%, and the minimum energy produced by PLTA increased by 72.53%. So that it can maximize reservoir performance without experiencing damage. This is expected to provide an overview of the optimal release guidelines for the operation of the Kuningan reservoir to meet the needs for irrigation, raw water and hydropower.