Background: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients. Objective: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR). Methods: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR. Results: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR. Conclusion: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.
The photon counting detector (PCD) in computed tomography (CT) can count the number of incoming photons in order to obtain energy information for photons corresponding to user-defined thresholds. Research on the extraction of effective atomic number (EAN) and relative electron density (RED) using dual-energy CT (DECT) is currently underway. This study proposes a method for improving EAN and RED accuracy of tissue-equivalent materials by using PCD-CT-based stoichiometric calibration. After obtaining DECT images in energy bin (EB) and full spectrum (FS) modes for eight tissue-equivalent materials, the EAN was calculated with stoichiometric calibration. Using the EAN image, the RED image was acquired to evaluate the accuracy. The errors of both EAN and RED obtained with EB were within 4%. In particular, the accuracy of RED was higher than that of the FS method. Study results indicate that PCD-CT contributes to improving EAN and RED accuracy. Further studies will be aimed at reducing ring artifacts by pixel-correcting PCD images and improving stopping power ratio (SPR) measurements for dose calculation in particle therapy.
Background: Children have a potential risk from radiation exposure because they are more sensitive to radiation than adults. Objective: The purpose of this work is to estimate image quality according to tube voltage (kV) and radiation dose in pediatric computed tomography (CT) using deep learning reconstruction (DLR). Methods: Phantom images of children and adults were obtained for kV, radiation dose, and image reconstruction methods. The CT emits a fan beam to the opposite detector, and the geometry of the detector was symmetrical. Phantom images of children and adults were acquired at a volume CT dose index (CTDIvol) from 0.5 to 10.0 mGy for tube voltages at 80, 100, and 120 kV. A DLR was used to reconstruct the phantom image, and filtered back projection (FBP) and iterative reconstruction (IR) were also performed for comparison with the DLR. Image quality was evaluated by measuring the contrast-to-noise ratio (CNR) and noise. Results: Under the same imaging conditions, the DLR images of pediatric and adult phantoms generally provided improved CNR and noise compared with the FBP and IR images. At a similar CNR and noise, the FBP, IR, and DLR of the pediatric images showed a dose reduction compared with the FBP, IR, and DLR of the adult images, respectively. In terms of the effect of tube voltage, the CNR of the 100 kV DLR images was higher than that of the 120 kV DLR images. Conclusion: According to the results, since pediatric CT images maintain the same image quality at lower doses compared with adult CT images, DLR can improve image quality while reducing the radiation dose in children’s abdominal CT scans.
X-ray mammography can be used to acquire images useful for early breast cancer detection in medical applications. There have been a number of approaches to diagnostic low-dose mammography. The purpose of this study was to design a concept for use of monochromatic X-ray beams by using K-edge filters for low dose mammography. The SRS-78 X-ray simulation code and Monte Carlo simulation GATE code were used to model the X-ray tube, target material, filter material, breast phantom, and detector. To achieve a monochromatic X-ray beam, molybdenum (Mo) and rhodium (Rh) were used as filter materials in various thicknesses. The direct conversion detector (FDXD 1417, Drtech, Seongnam, Korea) composed of thin-film transistor (TFT)-amorphous selenium (a-Se) was modelled through Monte Carlo simulation. According to the CVR and EER results, the filter thickness for optimal mammographic imaging is set to 6 and 3 HVL for Mo and Rh, respectively. SNR values with the Rh filter improved by 1.01, 6.28, 5.60, 5.60, 5.60, 5.60 % over the range from 0.1 to 0.6 μGy compared to analogous SNR values without filter. The present work demonstrates that monochromatic X-ray beams can be generated for low dose mammography. According to the results, Rh filter could be useful for enhancing calcification while absorbed dose is reduced.