Myung-Ae Chung

Prof. Dr. Myung-Ae Chung

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
PJPil-Hyun Jeon
Pil-Hyun Jeon
SJSang-Hyun Jeon
Sang-Hyun Jeon
DKDonghee Ko
Donghee Ko
GAGiyong An
Giyong An
HSHackjoon Shim
Hackjoon Shim
MCMyung-Ae Chung
Myung-Ae Chung
Background: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients. Objective: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR). Methods: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR. Results: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR. Conclusion: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.

8 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MCMyung-Ae Chung
Myung-Ae Chung
TKTaehoon Kim
Taehoon Kim
KKKyung-A Kim
Kyung-A Kim
MKMin-Soo Kang
Min-Soo Kang
In this study, we applied an optimal deep learning algorithm to detect defects in OLED cells. This study aims to enhance the yield of OLEDs by reducing the number of defective products through defect detection in OLED cells. Defects in OLED cells can arise owing to various factors, but dark spots are predominantly identified and studied. Therefore, actual dark spot images were required for this study. However, obtaining real data is challenging because of security concerns in the OLED industry. Therefore, a Solver program utilizing the finite element method (FEM) was employed to generate 2000 virtual dark spot images. The generated images were categorized into two groups: initial images of dark spots and images obtained after 10,000 h. The pixel values of these dark spot images were adjusted for efficient recognition and analysis. Furthermore, CNN, ResNet-50, and VGG-16 were implemented to apply the optimal deep learning algorithms. The results showed that the VGG-16 algorithm performed the best. A defect detection model was created based on the performance metrics of the deep learning algorithms. The model was trained using 1300 dark spot images and validated using 600 dark spot images. The validation results indicated an accuracy of 0.988 and a loss value of 0.026. A defect detection model that utilizes the VGG-16 algorithm was considered suitable for distinguishing dark spot images. To test the defect detection model, 100 images of dark spots were used. The experimental results indicated an accuracy of 89%. The images were classified as acceptable or defective based on the threshold values. By applying the VGG-16 deep learning algorithm to the defect detection model, we can enhance the yield of OLED products, reduce production costs, and contribute significantly to the advancement of OLED display manufacturing technology.

14 February 2023 in Symmetry
Verified
Journal Article
Open access
PDF file
DKDaehong Kim
Daehong Kim
PJPil-Hyun Jeon
Pil-Hyun Jeon
CLChang-Lae Lee
Chang-Lae Lee
MCMyung-Ae Chung
Myung-Ae Chung
Background: Children have a potential risk from radiation exposure because they are more sensitive to radiation than adults. Objective: The purpose of this work is to estimate image quality according to tube voltage (kV) and radiation dose in pediatric computed tomography (CT) using deep learning reconstruction (DLR). Methods: Phantom images of children and adults were obtained for kV, radiation dose, and image reconstruction methods. The CT emits a fan beam to the opposite detector, and the geometry of the detector was symmetrical. Phantom images of children and adults were acquired at a volume CT dose index (CTDIvol) from 0.5 to 10.0 mGy for tube voltages at 80, 100, and 120 kV. A DLR was used to reconstruct the phantom image, and filtered back projection (FBP) and iterative reconstruction (IR) were also performed for comparison with the DLR. Image quality was evaluated by measuring the contrast-to-noise ratio (CNR) and noise. Results: Under the same imaging conditions, the DLR images of pediatric and adult phantoms generally provided improved CNR and noise compared with the FBP and IR images. At a similar CNR and noise, the FBP, IR, and DLR of the pediatric images showed a dose reduction compared with the FBP, IR, and DLR of the adult images, respectively. In terms of the effect of tube voltage, the CNR of the 100 kV DLR images was higher than that of the 120 kV DLR images. Conclusion: According to the results, since pediatric CT images maintain the same image quality at lower doses compared with adult CT images, DLR can improve image quality while reducing the radiation dose in children’s abdominal CT scans.

1 January 2025 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
KKKyung-A Kim
Kyung-A Kim
MKMin-Soo Kang
Min-Soo Kang
BCByoung Geol Choi
Byoung Geol Choi
JAJihun Ahn
Jihun Ahn
WKWonho Kim
Wonho Kim
MCMyung-Ae Chung
Myung-Ae Chung
Kim KA, et al. Yonsei Med J. 2025 Jan;66:e23. https://doi.org/10.3349/ymj.2024.0067

28 January 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
HLHyo-Bin Lee
Hyo-Bin Lee
DKDaehong Kim
Daehong Kim
HLHaenghwa Lee
Haenghwa Lee
MCMyung-Ae Chung
Myung-Ae Chung
Purpose: This study introduces an Adaptive Optimization–based Multi-Material Decomposition with Total Nuclear Variation (AO-MMD-TNV) for dual-energy CT (DECT), designed to achieve accurate and noise-robust material fraction estimation. Methods: Three experimental datasets—a digital phantom, a tissue characterization phantom, and a human-shaped phantom—were used to evaluate the proposed method. The algorithm combines a robust Huber data term, iteratively reweighted L1 sparsity, and Total Nuclear Variation (TNV) regularization under simplex constraints. Adaptive weighting was applied to balance physical fidelity, sparsity, and boundary coherence. The performance was quantitatively compared with a conventional triplet-based MMD approach using metrics of volume fraction accuracy (VFA) and standard deviation (STD). Results: The AO-MMD-TNV achieved 100% VFA for all five materials in the digital phantom, with complete noise suppression (STD = 0). In the tissue characterization phantom, the method demonstrated improved VFA in most ROIs, though minor accuracy reductions were observed for breast and solid water (ROIs 3 and 4) due to their similar attenuation to background. In the human-shaped phantom, the AO-MMD-TNV maintained stable performance across six organ-related ROIs, outperforming MMD in quantitative consistency and noise robustness. Conclusions: The proposed AO-MMD-TNV framework effectively enhances quantitative reliability, reduces noise and crosstalk, and preserves anatomical boundaries. While further optimization is needed for low-contrast materials, AO-MMD-TNV demonstrates strong potential for precise, physically consistent DECT-based material quantification and clinical application.

30 December 2022 in Journal of Appropriate Technology
Verified
Journal Article
Open access
PDF file
MPMiyoung Park
Miyoung Park
MCMyung-Ae Chung
Myung-Ae Chung
KAKyungsook Ahn
Kyungsook Ahn
In Kenya, the 'Linda Mama Program', a free care program for pregnant women, is being implemented, but as of 2017, maternal deaths per 100,000 live births reached 342, and the infection rate such as AIDS, hepatitis B, and syphilis is high. Diagnosis is being made centering on a quick simple test (rapid diagnosis), but the reliability is low, so an accurate and quick diagnosis method is needed. Through the Innovative Technology Program (CTS) of Korea International Cooperation Agency (KOICA), we developed a multi-immune diagnostic device and multi-diagnostic kit that can diagnose AIDS, hepatitis B, and syphilis, which can be tested with minimal education at schools and local public health centers in addition to hospitals. The sensitivity and specificity of the diagnostic kit were each 90% or more, which was improved by more than 20% compared to the rapid diagnostic kits. The supply of cost-competitive diagnostic devices and test kits will enable continuous monitoring of AIDS, hepatitis B, and syphilis infections among women of childbearing age between the ages of 15 and 49, thereby contributing to the improvement of maternal and child health.