This work considers the enhancement of indoor bioaerosol removal efficiency by liquid coating of the antimicrobial agent chitosan onto polypropylene fibrous filters (CCFs). Escherichia coli (E. coli) and Bacillus subtilis (B. subtilis) were chosen as the tested bioaerosols. The results revealed that 2.5% (w/w) of CCFs have significantly higher bioaerosol survival capability (23% and 34% of E. coli and B. subtilis, respectively), compared to an untreated filter (65% and 64% for E. coli and B. subtilis, respectively). Increasing face velocity and relative humidity during operating CCFs could reduce the bioaerosol removal capability. The regression analysis of the experimental findings demonstrated that the higher coating concentration of chitosan had the most positive influence on bioaerosol removal, while the face velocity and relative humidity had a negative influence, but a milder effect was observed (R2 = 0.83 and 0.81 for E. coli and B. subtilis bioaerosols, respectively). A CCF-loaded air-cleaning device was tested in a real indoor environment and resulted in 80.1% bioaerosol removal within 3 h of operating, which suggests that the chitosan-coated filter has the potential for further application in improving indoor air quality in the future.
This work considers the ability of carbon-nanotube (CNT)-coated plasma to inactivate bioaerosols. Escherichia coli (E. coli) and λ virus phage were chosen as the challenge bioaerosols. A test chamber was used to simulate an indoor environment and to control the air exchange rate (ACH). The results demonstrated that CNT-coated plasma had a significant antimicrobial effect on both bacterial and viral bioaerosols. The experimental results revealed that CNT-coated plasma under an operating voltage of 6.0 kV and an ACH of 0.5 h−1 had significantly higher bioaerosol inactivating ability (kCNT, 0.24 and 0.23 min−1 for E. coli and λ virus phage, respectively) compared to the results without using CNT-coated plasma (kn, 0.09 and 0.08 min−1 for E. coli and λ virus phage, respectively). Under the higher ACH condition, the system demonstrated higher bioaerosol removal efficiency due to the mechanical effect of clean air exchange. Increasing flow rate and operating voltage could raise the inactivating ability of the CNT-coated plasma system. A CNT-coated plasma air-cleaning device was tested in a real indoor medical environment and yielded bacterial bioaerosol removal efficiency in the range from 70% to 80% within 6 h of operation (7.5 Lpm and 6.0 kV), which suggests that CNT-coated plasma treatment has the potential for further application in improving indoor air quality.
This study aimed to examine whether different agricultural work patterns may cause MSDs in different body areas and assess their severity. In previous studies, musculoskeletal disorders (MSDs) have been recognized as an occupational disease in agricultural workers. However, not all MSDs resulting from agriculture occur in the same body areas or have similar severity. This study conducted a questionnaire survey to inquire about the body areas and severity of MSDs among fruit farmers. A total of 212 valid answers were collected. Subsequently, their main harvesting postures were classified into three groups to examine the differences in MSD occurrence and severity among those groups. The results indicate that the harvesting posture did result in different severities of MSDs in certain body areas. Raising hands above the shoulders caused significantly higher MSD severity in the neck, shoulder, upper back, and elbows despite the same standing posture. Additionally, those who squatted, bent, or kneeled had a significantly higher severity of MSDs in the shoulders compared to those who stood but did not raise their hands above their shoulders. This study confirmed that the different harvesting heights of fruits can affect farmers’ posture, leading to differences in the body areas affected by, and severity of, MSDs.
1 May 2018 in IOP Conference Series: Earth and Environmental Science
This work applied ozone water spraying to explore the feasibility of inactivating bioaerosol. The inactivating efficiency using ozone water (OW) spraying individually against airborne strains Escherichia coli (E. coli) bioaerosols was evaluated in the testing chamber. The setting air exchanged rate (ACH) in this work were 0.5 and 1.0 h−1. The OW operating concentration of 0.5 and 1.0 ppm were sprayed into the testing chamber for inactivating bioaerosols, respectively. Higher OW spraying concentration showed better inactivating results. The inactivation constant of E.Coli against WO 0.5 and 1.0 ppm spraying under ACH 1.0 h−1 was 0.236 and 0.435 (min−1). Moreover, the bioaerosol removal efficiency would increase with ACH. The inactivation decay coefficient of WO 1.0 ppm spraying against E.Coli was 0.312 and 0.435 (min−1) under ACH 1.0 and 0.5 h−1. The results demonstrated that the WO spraying technology was effective in inactivating bioaerosols.
Conventional antimicrobial air filters often conflate physical interception with true biochemical inactivation, posing secondary aerosolization risks during maintenance. This study developed a lactoferricin B-functionalized polypropylene (LfCF) filter to provide a dual-action mechanism: electrostatic capture and robust contact-killing against bioaerosols. To rigorously decouple these mechanisms, a polyallylamine binder-only (PP+PAA) control was incorporated. Dynamic penetration assays at 10 cm/s revealed that the 2.0 mg LfCF achieved significantly lower viable penetration rates for Escherichia coli (41.2%) and λ phage (46.0%) compared to the PP+PAA control (75.1% and 76.3%). This substantial gap demonstrates instantaneous sublethal injury upon aerodynamic impaction, defined here as “dynamic inactivation.” Crucially, time-dependent elution assays confirmed a >2 log reduction in viable counts for both retained E. coli and λ phage on LfCFs within 60 min, definitively validating its genuine contact-killing capability. Furthermore, the amphipathic lactoferricin B peptide maintained exceptional biocidal efficacy even under high-humidity conditions (70% RH), overcoming the electrostatic shielding typical of traditional biopolymers, without increasing aerodynamic pressure drop. Finally, field validation in a dental clinic demonstrated an 83.3% reduction in airborne viable bioaerosols. As a passive, self-sterilizing engineering control, the LfCF offers a highly reliable intervention for mitigating occupational bioaerosol exposures.