The microgrids operate in tie-up (TU) mode with the main grid normally, and operate in isolation (IN) mode without the main grid during faults. In a dynamic operational regime, protecting the microgrids is highly challenging. This article proposes a new microgrid protection scheme based on a state observer (SO) aided by a recurrent neural network (RNN). Initially, the particle filter (PF) serves as a SO to estimate the measured current/voltage signals from the corresponding bus. Then, a natural log of the difference between the estimated and measured current signal is taken to estimate the per-phase particle filter deviation (PFD). If the PFD of any single phase exceeds the preset threshold limit, the proposed scheme successfully detects and classifies the faults. Finally, the RNN is implemented on the SO-estimated voltage and current signals to retrieve the non-fundamental harmonic features, which are then utilized to compute RNN-based state observation energy (SOE). The directional attributes of the RNN-based SOE are employed for the localization of faults in a microgrid. The scheme is tested using Matlab® Simulink 2022b on an International Electrotechnical Commission (IEC) microgrid test bed. The results indicate the efficacy of the proposed method in the TU and IN operation regimes on radial, loop, and meshed networks. Furthermore, the scheme can detect both high-impedance (HI) and low-impedance (LI) faults with 99.6% of accuracy.
In the modern world, High Impedance (HI) Faults’ identification is challenging in renewable energy-based distribution networks (REBDNs) due to the low level of the fault current. In this paper, a new HI fault detection/classification strategy is presented for REBDNs, based on the time-varying Kalman Filter (TVKF). Initially, TVKF is applied to the voltage and current signal of each phase separately, in order to extract harmonic components. Secondly, the TVKF-based harmonic components are utilized to calculate the single-phase reactive power (SPRP) independently. If the SPRP of any individual phase is greater than a specific threshold value, the corresponding phase is considered faulty. Fault classification is autonomous due to phase segregation. The proposed strategy is tested on the REBDNs’ test system in MATLAB/Simulink software. The results indicate that the proposed scheme detects and classifies HI faults under radial and mesh topologies.
The electrification of ferries requires efficient shore infrastructures that include energy supply grids, communication networks, charging systems, energy storage systems, interfacing and monitoring devices. In this context, a lot of research and development efforts have been made in the last decade that are reviewed in this paper. Energy storage technologies, battery charging requirements and their safety parameters are first analyzed. A comprehensive review on shore side infrastructure design and power system architecture are then provided. Different shore to ship interfaces are finally presented along with, some alternative solutions to battery charging stations.
The substantial growth in energy utilization, and the expansion of renewable energy resources, mainly winds and solar, poses challenges to the environment and energy security. Therefore, smart energy meters (SEMs) are the bottom-line modules in such renewable-energy-based networks (REBNs). Apart from the measurement of energy flows, smart energy meters are capable of the give-and-take of complete information on the utilization of energy and the status of energy networks between end consumers and utilities. Moreover, according to the individual consumer’s commands, the SEMs can also be utilized for the monitoring and control of the consumer’s electrical devices. The presented paper scientifically reviews the present development of SEMs, together with the other meters such as smart gas (SG), smart heat (SH), and electricity (SE) meters. Furthermore, we present the various functions and applications of SEMs. Lastly, this paper provides conclusive remarks and the future direction of SEMs.
18 February 2025 in IEEE Open Journal of Power Electronics
This paper proposes a simple mixed-carrier-based PWM strategy driven through a hysteresis control to address the issues related to voltage imbalances and low-frequency oscillation in the DC-link capacitors voltage. The goal of this approach is to avoid extra power losses, power quality issues and reduced lifespan of capacitors by exploiting the features of conventional dual-carrier PWM strategies. This technique offers a remarkably low computational burden, outstanding performance in terms of power quality and losses, and it does not require additional power circuits. The proposed approach is first introduced theoretically, then its performance is exhaustively assessed through simulations and experimental tests by demonstrating a significant reduction of capacitor sizing. Additionally, an experimental performance comparison analysis is performed with a conventional three-level PWM strategy. Finally, to prove its merits with respect to other carrier-based PWM strategies proposed in the literature, a comparison in terms of current and voltage transducers, control algorithm complexity, computational cost and total harmonic distortion is provided.
24 November 2025 in IEEE Transactions on Transportation Electrification
This article presents the design and development of a hybrid multilevel inverter for electric vehicle (EV) applications employing an open-end winding motor (OEWM) configuration. This architecture allows for the use of commercially available 650-V GaN devices in EVs with high-voltage (800–1000 V) batteries. It combines a three-level T-type converter with silicon IGBTs (Si-IGBTs), which processes the full battery voltage at a low switching frequency, with an auxiliary two-level GaN inverter operating at a lower voltage (below 350 V) and at 50 kHz to play the role of an active filter. This results in a six-level output voltage waveform, leading to approximately 50% lower voltage total harmonic distortion than conventional solutions. Experimental validation confirms that the proposed topology achieves high efficiency and improved voltage and current waveforms. It also reduces common-mode voltage while decreasing the number of power devices and the overall system volume and cost relative to conventional fully GaN-based multilevel converters. Additionally, since operating GaN devices at high switching frequencies (above 50–100 kHz) in vehicular applications is counterproductive, as it increases switching losses without significantly improving the quality of voltage and current waveforms, a relatively low switching frequency is adopted for GaN devices to exploit their full potential in improving efficiency.