Groundwater is one of the main water sources for consumption, domestic use, agriculture, and tourism in coastal communities. However, high total dissolved solids (TDS) levels in the water (700–2000 mg L−1 TDS) and electrical conductivity (3000–5000 µS cm−1) threaten the health and economic growth opportunities for residents. This research aims to evaluate the performance of a laboratory-scale electrodialysis system as a technology for desalinating brackish water. For this purpose, water samples were collected from real groundwater sources. Batch experiments were conducted with varying operational parameters, such as voltage (2–10 V), feed volume (100–1600 mL), recovery rate (50–80%), and cros-flow velocity (1.3–5.1 cm s−1) to determine the electrodialysis system setup that meets the requirements for drinking water in terms of TDS and energy efficiency. A total specific energy consumption of 1.65 kWh m−3, including pumping energy, was achieved at a laboratory scale. The conditions were as follows: flow velocity of 5.14 cm s−1, applied voltage of 6 V, feed volume of 1.6 L, and a water recovery of 66%. Furthermore, increasing the flow velocity and the applied voltage enhanced the desalination kinetics and salt removal. Additionally, the system presented opportunities for scalability. This research aims to evaluate a sustainable membrane-based treatment technology for meeting the growing demand for water resources in coastal communities, particularly in developing countries in South America.
19 March 2024 in Case Studies in Chemical and Environmental Engineering
Granting access to drinking water has been a challenge because 47% of the worldwide population is not connected to a drinking water distribution network in rural settlements. This study aimed to evaluate the contaminant removal efficiency in a conventional water treatment facility in the Austro region of Ecuador, Paute, to identify the treatment units requiring hydraulic resizing. Water samples were collected from each treatment unit to characterize the physical-chemical and microbiological parameters, and the dimensions of the treatment ponds for hydraulic evaluation purposes. Water hardness, electrical conductivity, SO42−, and Fe2+ were the main issues found in the water, which failed to comply with Ecuadorian technical guidelines. The treatment units, such as the flocculator, rapid sand filter, and storage tank, were resized to meet the demand of the future population. In addition, the residual free chlorine was measured as insufficient in the community’s tap water, showing an unprotected water distribution system to microbiological contamination. No disinfection by-products were found despite the existence of biodegradable organic matter. The findings of this research propose improvements in the deployed treatment practices to provide the community with drinking water in accordance with the Sustainable Development Objectives (SDG 3 and SDG 6).
The design and deployment of a conventional water treatment experiment, the Jar Test, are presented in a virtual format. It used a low-cost online platform to reproduce the experimental steps and the actual lab setting to empower students with experiential skills. Skills like experimentation, instrumentation, learning from failure, and communication for their professional success. These skills are evaluated in the accreditation criteria for engineering programs of the Accreditation Board for Engineering and Technology. This virtual experience provided one-hundred and sixty-three civil engineering students with the knowledge to perform experimentation at an engineering level, from water sampling campaigns to performing the Jar Test experiment and measuring physicochemical quantities to draw technical conclusions. According to students’ perceptions, the simulation strengthened their capacity for conducting experiments and data collection-processing using virtualized lab instruments. It also consolidated theoretical knowledge to report conclusions according to research findings and enhanced their confidence to perform in-person experiments based on the revised virtual procedure. The results from this study demonstrate that virtual tools could be deployed as a powerful supplement to deliver the practical syllabus when limitations of face-to-face interaction occur. It can also be a blended educational approach since the computer-assisted simulation provides the necessary pre-knowledge that maximizes learning during in-person experimentation.
The presence of aniline, a toxic aromatic amine, has been recorded in different industrial wastewaters. This study aims to investigate the transport of charged and neutral aniline species in aqueous solutions through hydrophobic and ion-exchange membranes (IEMs). Hydrophobic polyoctylmethylsiloxane (POMS) and polydimethylsiloxane (PDMS) membranes and cationic (CEMs) and anionic (AEMs) exchange membranes were tested using diffusion cells and electrodialysis (ED). Diffusion experiments showed that neutral aniline removal reached 90% with POMS and 100% with PDMS due to the concentration gradient between feed (pH = 10) and receiving (pH = 3) solutions. For IEMs, neutral aniline exhibited a faster transport than charged species, with neutral-to-charged transport ratios of 6.6:1 for AEMs and 3.2:1 for CEMs, type I. During ED experiments, an external electric potential increased the charged aniline transport, achieving higher initial fluxes (124.7 mmol·m2·h−1 at pH 4) compared to neutral aniline (43.6 and 53.2 mmol·m2·h−1 for AEMs and CEMs, type I). ED also demonstrated that charged aniline can be removed up to 97% using IEMs. These findings demonstrate the effectiveness of hydrophobic and IEMs in removing aniline, providing insights into its transport mechanism, contributing to the optimization of membrane technologies in treating industrial wastewater effluents, and environmental sustainability.