In-Young Choi

Mr. In-Young Choi

Konkuk University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jo-Chun KimJo-Chun Kim
Jo-Chun Kim
Trieu-Vuong DinhTrieu-Vuong Dinh
Trieu-Vuong Dinh
HOHong Keun Oh
Hong Keun Oh
YSYoun-Suk Son
Youn-Suk Son
JAJi-Won Ahn
Ji-Won Ahn
KKKi-Hyun Kim
Ki-Hyun Kim
Biological volatile organic compounds (BVOCs) are emitted abundantly from the flora. Among BVOCs, monoterpenes (MTs) have been used for aromatherapy (e.g., forest bathing) to treat human physiological and psychological conditions. However, relatively little is known about the therapeutic effects of MTs at low part per billion by volume (ppbv) levels. The effects of artificial MTs on human subjects were assessed by both olfactory and therapeutic parameters (brain alpha waves and stress index). Gaseous standards of three monoterpenes (i.e., α-pinene, β-pinene, and d-limonene) prepared at low ppbv levels were used individually and as mixtures. Fifty-nine healthy and non-asthmatics volunteer university students were selected for the test. All human subjects inhaled low ppbv levels of monoterpene in the testing room. Brain alpha waves and stress index were investigated during the inhalation time. Questionnaires were also used after testing. It was found that the detection threshold of MTs was close to 5 ppbv. When the MT levels increased from 0 to 20 ppbv, the mean values of brain alpha waves derived from all participants increased from 9.8 to 15.1. In contrast, the stress index values declined from 46.2 to 34.7. The overall results suggest that MTs have great potential to positively affect the relaxation state of subjects in a manner similar to forest bathing in terms of short-term effect. They can thus be applied as potential therapeutic media for mental health care.

DKDong-June Kim
Dong-June Kim
Trieu-Vuong DinhTrieu-Vuong Dinh
Trieu-Vuong Dinh
JLJooyeon Lee
Jooyeon Lee
ICIn-Young Choi
In-Young Choi
DSDong-Jin Son
Dong-Jin Son
Jo-Chun KimJo-Chun Kim
Jo-Chun Kim
Water vapor is a pivotal obstacle when measuring ambient air pollutants. The effects of water vapor removal devices which are called KPASS (Key-compound PASSer) and Cooler. On the measurement of O3, SO2, and CO at ambient levels were investigated. Concentrations of O3, SO2, and CO were 100 ppb, 150 ppb, and 25 ppm, respectively. The amount of water vapor varied at different relative humidity levels of 30%, 50%, and 80% when the temperature was 25 °C and the pressure was 1 atm. Water vapor removal efficiencies and recovery rates of target gases were also determined. The KPASS showed a better performance than the Cooler device, removing 93.6% of water vapor and the Cooler removing 59.2%. In terms of recovery, the KPASS showed a better recovery of target gases than the Cooler. Consequently, it is suggested that the KPASS should be an alternative way to remove water vapor when measuring O3, SO2, and CO.

27 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JLJooyeon Lee
Jooyeon Lee
Trieu-Vuong DinhTrieu-Vuong Dinh
Trieu-Vuong Dinh
DKDong-June Kim
Dong-June Kim
ICIn-Young Choi
In-Young Choi
JAJi-Won Ahn
Ji-Won Ahn
Jo-Chun KimJo-Chun Kim
Jo-Chun Kim
A major problem of measuring polar compounds in the air is water vapor. Therefore, it is important to use a water pretreatment device prior to sampling and analysis. However, many studies have reported the occurrence of many problems following the application of an existing water pretreatment device. Accordingly, the performance of a Desolvator-K that was developed by the authors and two commercial coolers were investigated and compared in this study. Water vapor removal efficiency, recovery rate, and reproducibility of polar odorous compounds (i.e., methyl ethyl ketone (MEK), isobutyl alcohol (i-BuAl), methyl isobutyl ketone (MIBK), butyl acetate (BuAc), styrene) in air were taken into account. It was found that the Desolvator-K, the Cooler-G, and the Cooler-K showed 91.6%, 67.2%, and 62.1% water vapor removal efficiency, respectively, at the relative humidity of 90%. In terms of recovery rate, after water vapor removal devices, the Desolvator-K, the Cooler-G, and the Cooler-K revealed average recoveries of 96.6–103%, 81–101%, and 88.6–100%, respectively. Reproducibility of odorous compounds under all conditions of the Desolvator-K, the Cooler-G, and the Cooler-K were 5.94%, 31.2%, and 8.14% of relative standard deviation (RSD), respectively. Therefore, it is suggested that the Desolvator-K should be established as a water pretreatment device for the MEK, i-BuAl, MIBK, and BuAc compounds in the air.

30 June 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Trieu-Vuong DinhTrieu-Vuong Dinh
Trieu-Vuong Dinh
ICIn-Young Choi
In-Young Choi
BPByeong-gyu Park
Byeong-gyu Park
JLJee-Hyun Lee
Jee-Hyun Lee
IKIn-Young Kim
In-Young Kim
Jo-Chun KimJo-Chun Kim
Jo-Chun Kim
An analyzer for measuring NH3 emitted from a combustion process has been developed based on a simple non-dispersive infrared (NDIR) technique because of its cost-effective benefit. The weakness of the NDIR analyzer due to interference and zero-drift has been overcome. A least-interfering bandpass filter (BPF) was found and manufactured to compensate for the interfering effects of gases emitted from a combustion process (e.g., CO, NOx, SO2, CO2, H2O, HCl, formaldehyde, acetaldehyde and toluene). It was found that there was no significant interference in the least-interfering BPF with respect to gases of concern. Measurement errors by the analyzer were less than 2.5% in a range of 1 to 10 ppmv of NH3 compared to a standard method when the compound was measured in complicated mixing gases. For the zero-drift, using BPFs with identical center wavelength with respect to different incident infrared intensity was found to help minimize the zero-drift of the NDIR analyzer. As a result, the analyzer could cut approximately 19% of zero-drift caused by the aging effect of both IR source and detector. It suggests that the analyzer could be applied for measuring NH3 emitted from combustion processes with good accuracy and reproducibility.

30 September 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ICIn-Young Choi
In-Young Choi
Trieu-Vuong DinhTrieu-Vuong Dinh
Trieu-Vuong Dinh
DKDong-Eun Kim
Dong-Eun Kim
Bong-Hyun JunBong-Hyun Jun
Bong-Hyun Jun
SLSeungae Lee
Seungae Lee
Jo-Chun KimJo-Chun Kim
Jo-Chun Kim
Stationary emission sources still account for a significant portion of total air pollution emissions. Continuous emission monitoring systems (CEMS) have been used to estimate the emissions of stack pollutants. A large amount of moisture and other interfering factors in the sample discharged from a stack result in the loss of target gases due to artifact formation or gas absorption, thereby reducing measurement accuracy. Therefore, a pretreatment process is essential. Among various pretreatment technologies available, a cyclone with a rapid cooling unit is a special one that can be applied to remove particles and water vapor at the same time in CEMS. This study aimed at the simultaneous removal of water vapor and particles by operating a hybrid pretreatment device at low temperatures such as −5, −15, and −25 °C. When using the hybrid cyclone under the conditions of high temperature (180 °C), humidity (150 g/m3), PM2.5 (1 mg/m3), and SO2 (105.2 ppm) concentrations, the reduction rates of water vapor and PM2.5 concentration and the recovery rates of SO2 concentration were 82.2, 80.2, and 96.4%, respectively. These data suggested that the hybrid cyclone could be used as a pretreatment device for CEMS.

11 March 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
SLSang-Woo Lee
Sang-Woo Lee
Trieu-Vuong DinhTrieu-Vuong Dinh
Trieu-Vuong Dinh
SPShin-Young Park
Shin-Young Park
ICIn-Young Choi
In-Young Choi
IKIn-Young Kim
In-Young Kim
Jo-Chun KimJo-Chun Kim
Jo-Chun Kim
In air pollutant monitoring using sensors, moisture can adversely affect the analytical accuracy of volatile organic compounds (VOCs). Therefore, a new moisture pretreatment device (KPASS–Odor) for analyzing VOCs in the air was developed, based on frost and created by a desublimation process inside a cold tube. The performance of KPASS–Odor was compared with conventional devices (i.e., a NafionTM dryer and a cooler) through the measurements of low water-soluble VOCs (i.e., benzene, toluene, ethyl benzene, p-xylene, and styrene) and relatively high ones (i.e., methyl-ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol) using gas chromatography (GC) and sensor methods. Regarding the GC method, the recovery rates for KPASS–Odor and the cooler were >95% and >80%, respectively, at a flow rate of 500 mL/min for all compounds. For the NafionTM dryer, the recovery rates differed between low and high water-soluble compounds, which exhibited the rates ≥88% and ≤86%, respectively. In terms of the sensor method, the VOC recovery rates of KPASS–Odor and the NafionTM dryer were found to be >90% and <50%, respectively. Therefore, KPASS–Odor was determined to be the most suitable moisture pretreatment device for highly soluble VOCs of concern in this study.