CELIA DE LA MORA OROZCO

Dr. CELIA DE LA MORA OROZCO

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
COCELIA DE LA MORA OROZCO
CELIA DE LA MORA OROZCO
HFHugo Flores-Lopez
Hugo Flores-Lopez
HRHector Rubio
Hector Rubio
ACAlvaro Chavez-Duran
Alvaro Chavez-Duran
Jesus M. Ochoa-RiveroJesus M. Ochoa-Rivero
Jesus M. Ochoa-Rivero
Pollution levels have been increasing in water ecosystems worldwide. A water quality index (WQI) is an available tool to approximate the quality of water and facilitate the work of decision-makers by grouping and analyzing numerous parameters with a single numerical classification system. The objective of this study was to develop a WQI for a dam used for irrigation of about 5000 ha of agricultural land. The dam, La Vega, is located in Teuchitlan, Jalisco, Mexico. Seven sites were selected for water sampling and samples were collected in March, June, July, September, and December 2014 in an initial effort to develop a WQI for the dam. The WQI methodology, which was recommended by the Mexican National Water Commission (CNA), was used. The parameters employed to calculate the WQI were pH, electrical conductivity (EC), dissolved oxygen (DO), total dissolved solids (TDS), total hardness (TH), alkalinity (Alk), total phosphorous (TP), Cl−, NO3, SO4, Ca, Mg, K, B, As, Cu, and Zn. No significant differences in WQI values were found among the seven sampling sites along the dam. However, seasonal differences in WQI were noted. In March and June, water quality was categorized as poor. By July and September, water quality was classified as medium to good. Quality then decreased, and by December water quality was classified as medium to poor. In conclusion, water treatment must be applied before waters from La Vega dam reservoir can be used for irrigation or other purposes. It is recommended that the water quality at La Vega dam is continually monitored for several years in order to confirm the findings of this short-term study.

26 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
Edgardo Martinez OrozcoEdgardo Martinez Orozco
Edgardo Martinez Orozco
PMPABLO GORTÁRES MOROYOQUI
PABLO GORTÁRES MOROYOQUI
NSNorberto Santiago-Olivares
Norberto Santiago-Olivares
Juan Nápoles ArmentaJuan Nápoles Armenta
Juan Nápoles Armenta
RMRuth Gabriela Ulloa Mercado
Ruth Gabriela Ulloa Mercado
EMEdna Meza-Escalante
Edna Meza-Escalante
Tequila vinasses is a mixture made from up to six still distillation two-stage process residual effluents. First stage fractions: residual must (60%), heads (0.9%) and tails (20.0%); second stage fractions: non-evaporated (8.0%), heads (0.1%) and tails (1.0%); the result is a more complex effluent for its treatment or biorefining. The objectives of this study were to: (a) characterize the five still distillation volatile streams in the Tequila 100% Agave processing; compounds: methanol, ethanol, acetaldehyde, ethyl acetate, sec-butanol, n-propanol, iso-butanol, n-butanol, iso-amyl, n-amyl, and ethyl lactate were detected by gas chromatography; calculated chemical oxygen demand from chemical composition had very high values (53,760–1,239,220 mg/L); measurement of pH (3.24–4.80), color (38.6 UC Pt-Co max), turbidity (46.1 max), electrical conductivity (3.30–172.20 μS/cm), and solid content (0 mg/L) was also made; (b) report an energy analysis (2.02 × 109 KWh) and CO2 production (429 × 106 kg) in the Tequila industry during 2019; (c) up to date residues (365.2 × 106 kg agave bagasse, 1146.1 × 106 kg agave leaves and 3300.0 × 106 L agave vinasse) in 2019; (d) economic analysis, current tequila vinasses treatment price is 16.00 USD/m3 but could reach a considerable fraction value if is bio-refined, a break down component analysis reach for five volatile streams $51.23–$140.00 USD/m3.

8 May 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Juan Nápoles ArmentaJuan Nápoles Armenta
Juan Nápoles Armenta
JVJuan Antonio Vidales-Contreras
Juan Antonio Vidales-Contreras
LLLuis Alonso Leyva-Soto
Luis Alonso Leyva-Soto
EMEdna Meza-Escalante
Edna Meza-Escalante
LDLourdes Mariana Díaz-Tenorio
Lourdes Mariana Díaz-Tenorio
LSLilian Alejandra Salcedo-Gastelum
Lilian Alejandra Salcedo-Gastelum
In Mexico, atrazine is widely used in agriculture to control broadleaf weeds. The objective of this research was to compare atrazine removal in water and energy consumption between an up-flow cylinder electro-oxidation reactor (UCER) and an up-flow rectangular electro-oxidation reactor (URER) using the response surface methodology. In each reactor, two titanium (Ti) mesh electrodes (cathodes) and one Titanium-Lead Dioxide (Ti-PbO2) mesh electrode (anode). Current intensity effects, electrolysis treatment time, and recirculation flow were evaluated. Synthetic water with 5 mg/L atrazine content was used. Optimum atrazine removal values were obtained at 2 A electric current, 180 min of treatment time, and 200 mL/min recirculation rate for both reactors: in these conditions an atrazine removal of 77.45% and 76.89% for URER and UCER respectively. However, energy consumption showed a significant difference of 137.45 kWh/m3 for URER and 73.63 kWh/m3 for UCER. Regarding energy efficiency, a 60% atrazine removal was reached in both reactors using less energy for UCER at (1.5 A–135 min–150 mL/min–25.8 kWh/m3) and for URER at (0.66 A–135 min–150 mL/min–20.12 kWh/m3).

25 September 2017 in Water
Verified
Journal Article
Open access
PDF file
RTRUBEN ALFONSO SAUCEDO TERAN
RUBEN ALFONSO SAUCEDO TERAN
COCELIA DE LA MORA OROZCO
CELIA DE LA MORA OROZCO
IAIrma Julieta González Acuña
Irma Julieta González Acuña
SGSERGIO GOMEZ-ROSALES
SERGIO GOMEZ-ROSALES
GAGerardo Domínguez Araujo
Gerardo Domínguez Araujo
HRHector Rubio
Hector Rubio
Anaerobic digesters generate effluent containing about 3000 mg L−1 of organic matter in terms of chemical oxygen demand (COD). This effluent must be treated before being reused or discharged into the environment. The objective of this study was to evaluate the efficiency of a trickling filter packed with red volcanic rock for the treatment of anaerobic digester effluent with COD concentrations of around 3000 mg L−1. The trickling filter consisted of an aluminum cylinder, 2 mm thick, 3 m high, and 1 m in diameter. To evaluate the efficiency of the treatment system, there were three experimental runs, each lasting 20 days (d). The predictor variable was the initial COD concentration, which ranged from 2002 to 3074 mg L−1. The hydraulic retention time was 9 h. The influent flow was 2.2 L min−1, which amounts to a hydraulic load of 4033 m3 m−2 day−1 and an organic load of 0.006342 to 0.009738 kg m−3 day−1 of COD. Independent of the initial concentration, COD removal efficiency was very high, varying from 90 to 96%. Final effluents met all the maximum permissible limits to be used as irrigation water, as well as for its release into natural or artificial water reservoirs, stored for agricultural crop irrigation.

6 May 2024 in Water
Verified
Journal Article
Open access
PDF file
EVElizabeth Garza Valverde
Elizabeth Garza Valverde
Celestino García GómezCelestino García Gómez
Celestino García Gómez
Juan Nápoles ArmentaJuan Nápoles Armenta
Juan Nápoles Armenta
LSLuis Samaniego-Moreno
Luis Samaniego-Moreno
Edgardo Martinez OrozcoEdgardo Martinez Orozco
Edgardo Martinez Orozco
COCELIA DE LA MORA OROZCO
CELIA DE LA MORA OROZCO
The wastewaters of nejayote and food waste leachate are polluting effluents with a high load of organic matter that cause great problems when discharged to water receptors. In this work, we investigated the treatment of nejayote wastewaters and food waste leachate for the production of microalgae Scenedesmus acutus and Haematococcus pluvialis. For Scenedesmus acutus, treatment with 10% food waste leachate and 90% growth medium resulted in a concentration of 5.34 g/L in 20 days (μmax = 0.16/day). Meanwhile, 10% nejayote and 90% medium growth produced 4.45 g/L at 20 days (μmax = 0.13/d). A significant reduction of up to 82.6% ammonium, 84.1% orthophosphate, and 87.25% COD was also observed between the different treatments. For Haematococcus pluvialis, the treatment of 90% food waste leachate and 10% growth medium produced a concentration of 4.73 g/L at 6 days (μmax = 0.71/day), while the mixture of 25% najayote, 25% food waste leachate, and 50% growth medium produced a concentration of 5.5 g/L at 20 days (μmax = 0.25/dat). A reduction of up to 97.8% ammonia, 97.4% orthophosphate, and 73.19% COD was also recorded. These findings demonstrated the potential to cultivate microalgae and extract biomolecules for commercial purposes.

17 July 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
Juan Nápoles ArmentaJuan Nápoles Armenta
Juan Nápoles Armenta
ISItzel Celeste Romero Soto
Itzel Celeste Romero Soto
LSLuis Samaniego-Moreno
Luis Samaniego-Moreno
LDLourdes Mariana Díaz-Tenorio
Lourdes Mariana Díaz-Tenorio
LLLuis Alonso Leyva-Soto
Luis Alonso Leyva-Soto
LPLaura Izascum Pérez-Valencia
Laura Izascum Pérez-Valencia
In this paper, the production of biomass, pigments, lipids, and carbohydrates and the elimination of ammonium and orthophosphate by the microalgae Chlorella vulgaris, grown in synthetic wastewater (SWW), were studied under different light intensities (3000–10,000 lux), pH (7.5–9.5) and daily illumination time (8–16 h). The best conditions for the autotrophic culture of microalgae were predicted using response surface methodology (RSM). The results showed that the adaptation of the microalgae for this nutrient source was effective. The best conditions for the cultivation of Chlorella vulgaris in SWW were 8.44 pH and a light intensity of 8433 lux in the daily illumination time of 16 h. Under optimal conditions, the production of microalgal biomass, chlorophyll-a, chlorophyll-b, carotenoids, lipids and carbohydrates was 0.534 g/L, 7.46 mg/mL, 3.53 mg/mL, 2.01 mg/mL, 21.40% and 28.46%, respectively. The removal efficiencies of ammonium and orthophosphate from SWW were 97.66% and 58.78% in autotrophic cultures. This investigation introduces a new aspect by verifying the optimized cultivation conditions with real municipal wastewater, indicating that the procedure could be utilized for sustainable production of bioproducts and efficient treatment of municipal wastewater.