Asami Hatamoto

Ms. Asami Hatamoto

Tokyo University of Agriculture and Technology, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2025 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Open access
NONaoki Omori
Naoki Omori
ANAkinori Nishizawa
Akinori Nishizawa
AHAsami Hatamoto
Asami Hatamoto
SŌShūji Ōtomo
Shūji Ōtomo
HNHiroyuki Nishida
Hiroyuki Nishida

13 March 2023 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
AHAsami Hatamoto
Asami Hatamoto
KEKenta Emori
Kenta Emori
HNHiroyuki Nishida
Hiroyuki Nishida
Dielectric barrier discharge plasma actuators (DBDPAs) have been investigated for active flow control. The discharge induces ionic wind, which can be utilized for flow control; however, it simultaneously heats the flow and the dielectric surface. The thermal characteristics of the DBDPA must be clarified for applications in thermo-fluid engineering, such as forced convective cooling. In this study, we constructed a similarity law for the time variation of the surface temperature, assuming that the induced flow was heated by the discharge and that the dielectric was heated by the airflow. The similarity law was derived from the one-dimensional heat conduction equation in the dielectric, and the spatially averaged normalized temperature was then formulated as a function of the Biot and Fourier numbers. To experimentally validate the similarity law, the surface temperature, thrust, and power consumption were measured. The induced flow temperature and heat transfer coefficient were estimated based on the thrust and power consumption. The measured results verified that the similarity law was valid, regardless of the dielectric material, thickness, or applied voltage. This result supports the hypothesis regarding the heating mechanism in which the airflow is heated by Joule heating and the dielectric is heated by forced convection.

7 November 2022 in Actuators
Verified
Journal Article
Open access
PDF file
AHAsami Hatamoto
Asami Hatamoto
KNKumi Nakai
Kumi Nakai
HNHiroyuki Nishida
Hiroyuki Nishida
A tri-electrode plasma actuator (TED-PA), which has an additional electrode with a DC voltage, induces jets from two facing electrodes and achieves larger thrust and higher efficiency than a conventional dielectric barrier discharge plasma actuator. However, there are problems such as the large potential difference between the exposed electrodes, which can cause sparks and device destruction. Therefore, it is necessary to clarify the working mechanism of TED-PAs and optimize their configuration and applied voltage. In this study, we obtained the discharge photograph, the thrust, and the flow velocity field and investigated the characteristics of the DC voltage and the frequency of the AC voltage. To isolate the effects of the discharge from the potential variation, a corona discharge plasma actuator and a TED-PA were compared. As a result, increasing the frequency of the AC voltage induced stronger jets from the AC and DC electrodes. This result indicates that the barrier discharge enhances the jet from the DC electrode without changing the potential difference between the electrodes.

28 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
ANAkinori Nishizawa
Akinori Nishizawa
AHAsami Hatamoto
Asami Hatamoto
SŌShūji ŌTOMO
Shūji ŌTOMO
HNHiroyuki Nishida
Hiroyuki Nishida
Efficient heat transfer enhancement under forced convection is crucial for the performance and reliability of modern engineering systems. Dielectric barrier discharge plasma actuators (DBDPAs) have attracted attention for active heat transfer control. However, gas heating remains a challenge, as it often offsets the cooling effect of flow acceleration. We present a decoupled model that separates wall temperature changes into two components: flow-acceleration effects (Nusselt number changes) and gas-heating effects (temperature increase). The validity of this model was verified through numerical simulations. Our results confirm that the change in the Nusselt number is uniquely scaled by the thrust coefficient, consistent with prior studies. Furthermore, we find that the temperature increase due to gas heating varies linearly with the power consumption coefficient, with its proportionality determined by the thrust coefficient. Crucially, by combining these relations, this study demonstrates that the total net change in wall temperature induced by DBDPA driving can be explicitly formulated as a function of only two key dimensionless parameters: the thrust coefficient and the power consumption coefficient. This formulation enables the precise, quantitative prediction of the complex trade-off between acceleration-based cooling and thermal heating, providing essential design guidelines for optimizing DBDPA-based thermal management systems.