Jellyfish are among the widely distributed nature creatures that can effectively control the fluidic flow around their transparent soft body, thus achieving movements in the water and camouflage in the surrounding environments. Till now, it remains a challenge to replicate both transparent appearance and functionalities of nature jellyfish in synthetic systems due to the lack of transparent actuators. In this work, a fully transparent soft jellyfish robot is developed to possess both transparency and bio-inspired omni motions in water. This robot is driven by transparent dielectric elastomer actuators (DEAs) using hybrid silver nanowire networks and conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)/waterborne polyurethane as compliant electrodes. The electrode exhibits large stretchability, low stiffness, high transmittance, and excellent conductivity at large strains. Consequently, the highly transparent DEA based on this hybrid electrode, with Very-High-Bond membranes as dielectric layers and polydimethylsiloxane as top coating, can achieve a maximum area strain of 146% with only 3% hysteresis loss. Driven by this transparent DEA, the soft jellyfish robot can achieve vertical and horizontal movements in water, by mimicking the actual pulsating rhythm of an Aurelia aurita . The bio-inspired robot can serve multiple functions as an underwater soft robot. The hybrid electrodes and bio-inspired design approach are potentially useful in a variety of soft robots and flexible devices.
Pregnancy monitoring is always essential for pregnant women and fetuses. According to the report of WHO (World Health Organization), there were an estimated 287,000 maternal deaths worldwide in 2020. Regular hospital check-ups, although well established, are a burden for pregnant women because of frequent travelling or hospitalization. Therefore, home-based, long-term, non-invasive health monitoring is one of the hot research areas. In recent years, with the development of wearable sensors and related data-processing technologies, pregnancy monitoring has become increasingly convenient. This article presents a review on recent research in wearable sensors, physiological data processing, and artificial intelligence (AI) for pregnancy monitoring. The wearable sensors mainly focus on physiological signals such as electrocardiogram (ECG), uterine contraction (UC), fetal movement (FM), and multimodal pregnancy-monitoring systems. The data processing involves data transmission, pre-processing, and application of threshold-based and AI-based algorithms. AI proves to be a powerful tool in early detection, smart diagnosis, and lifelong well-being in pregnancy monitoring. In this review, some improvements are proposed for future health monitoring of pregnant women. The rollout of smart wearables and the introduction of AI have shown remarkable potential in pregnancy monitoring despite some challenges in accuracy, data privacy, and user compliance.
19 December 2023 in ACS Applied Materials & Interfaces
Untethered annelids-inspired soft robots can be used in space-confined compliant interactions where remote actuation is necessary. In contrast to their fully-soft counterparts, incorporating origami concepts can streamline modeling and control while maintaining compliance. However, more comprehensive untethered locomotions from a single deployable robot remain research challenges, and there are only limited motion generation mechanisms available. This paper presents the design and actuation of a caterpillar-inspired biomimetic origami robot prototype. We created an open triangular spring model by the programmable origami backbone for its stability and tunable elasticity. Remotely actuation with internal and external permanent magnets can achieve various types of origami terrestrial locomotion. The prototype can deform and compress up to 26.7 % of its original length, and offer six different types of locomotion capabilities, demonstrating its versatility. A description of the design, programmable crease analysis, and actuation method of the robot is provided in this work. We further analyzed and demonstrated its various motion and functional capabilities and validated various performance parameters such as speed and force bearing capabilities. The normalised velocity of the proposed prototype (0.10 to 0.15) is comparable to most of the speeds achieved by similar motions in other representative works as covered in the paper, demonstrating that versatile motions can be achieved without sacrificing speed performance.
Optical and electrical properties of silver nanowire transparent conductive films with a broad range of nanowire lengths were studied. A proposed simulation model demonstrated similar behavior with experimental results for 30 and 90 μm nanowires, and thus it was used to expand the range of nanowire lengths from 10 to 200 μm. Theoretical results show that a lengthening of silver nanowires results in an increase of their optoelectronic performance; 200 μm long nanowire possess 13.5 times lower sheet resistance compared to 10 μm ones, while the transmittance remains similar for coverage densities of nanowires up to 25%. Moreover, the dependence of the sheet resistance on the length of nanowires changes non-linearly; from 10 to 20 µm, 20 to 80 µm and 80 to 200 µm the sheet resistance drops by a factor of 5, 2.25 and 1.2 respectively. Furthermore, a thickening of nanowire diameters from 30 to 90 nm decreases the sheet resistance to 5.8 times. Obtained results allow a deeper analysis of the silver nanowire transparent conductive films from the perspective of the length of nanowires for various optoelectronic applications.
Intra-abdominal pressure (IAP) is closely correlated with intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) diagnoses, indicating the need for continuous monitoring. Early intervention for IAH and ACS has been proven to reduce the rate of morbidity. However, the current IAP monitoring method is a tedious process with a long calibration time for a single time point measurement. Thus, there is the need for an efficient and continuous way of measuring IAP. Herein, a stretchable capacitive pressure sensor with controlled microstructures embedded into a cylindrical elastomeric mold, fabricated as a pressure sensing sleeve, is presented. The sensing sleeve can be readily deployed onto intrabody catheter balloons for pressure measurement at the site. The thin and highly conformable nature of the pressure sensing sleeve captures the pressure change without hindering the functionality of the foley catheter balloon.