Taym Darwish

Dr. Taym Darwish


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2022 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
ASAbdelrahman Salman
Abdelrahman Salman
TDTaym Darwish
Taym Darwish
MGMarwan Ghabra
Marwan Ghabra
OKObeda Kailani
Obeda Kailani
YHYusra Haddeh
Yusra Haddeh
SASara Alhassan
Sara Alhassan
Aim. To determine the prevalence and associations of keratoconus (KC) in a university student population in Syria. Methods. A prospective multicentre cross-sectional cohort study was conducted at two universities in Syria. Student volunteers were recruited from Tishreen University (Latakia governorate) and Damascus University (Damascus governorate). All participants underwent a comprehensive ocular examination. Placido/Scheimpflug-based corneal imaging using the Sirius (CSO, Florence. Italy), and a questionnaire to evaluate the baseline characteristics and medical history, as well as to highlight possible risk factors of KC. Univariate and bivariate analyses were performed. Results. The estimated prevalence of KC among all subjects was 1.43% (n = 12). A strong association between eye rubbing and keratoconus was found (OR 9.33, 95% CI 2.94–29.63, ). Damascus University participants had a higher prevalence of KC than Tishreen University. However, the difference was not statistically significant. Conclusion. The prevalence of keratoconus in this Syrian student population was 1.43%. The results of this study demonstrate a high prevalence of keratoconus in the study population. Early detection of keratoconus through screening may yield benefits in preventing devastating sequelae of KC in populations with a high prevalence.

1 January 2023 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
ASAbdelrahman Salman
Abdelrahman Salman
Cosimo MazzottaCosimo Mazzotta
Cosimo Mazzotta
OKObeda Kailani
Obeda Kailani
MGMarwan Ghabra
Marwan Ghabra
RORana Omran
Rana Omran
HAHala Alhaji
Hala Alhaji
Aim. To establish the diagnostic accuracy of corneal and epithelial thickness measurements obtained by spectral‐domain optical coherence tomography (SD‐OCT) in detecting keratoconus (KC) and suspect keratoconus (SKC). Methods. This retrospective study reviewed the data of 144 eyes separated into three groups by the Sirius automated corneal classification software: normal (N) (n = 65), SKC (n = 43), and KC (n = 36). Corneal thickness (CT) and epithelial thickness (ET) in the central (0–2 mm) and paracentral (2–5 mm) zones were obtained with the Cirrus high‐definition OCT. Areas under the curve (AUC) of receiver operator characteristic (ROC) curves were compared across groups to estimate their discrimination capacity. Results. ROC curve analysis revealed excellent predictive ability for ET variables: minimum (Min) ET (0_2), minimum‐maximum (Min‐Max) ET (0_2), superonasal‐inferotemporal (SN‐IT) ET (2_5), Min‐Max ET (2_5), and Min ET (2_5) to detect keratoconus (AUC > 0.9, all). Min‐Max CT (0_2) was the only CT parameter with excellent ability to discriminate between KC and N eyes (AUC = 0.94; cutoff = ≤−32 μm). However, both ET and CT variables were not strong enough (AUC < 0.8, all) to differentiate between SKC and N eyes, with the highest diagnostic power for Min‐Max ET (2_5) (AUC = 0.71; cutoff = ≤−9 μm) and central corneal thickness (CCT) (AUC = 0.76; cutoff = ≤533 μm). Conclusion. These results demonstrate that OCT‐derived CT and ET are able to differentiate between KC and N eyes, with a high level of certainty. However, Min‐Max ET (2_5) was the parameter with the highest ability to detect suspect keratoconus.

18 May 2022 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
ASAbdelrahman Salman
Abdelrahman Salman
MGMarwan Ghabra
Marwan Ghabra
TDTaym Darwish
Taym Darwish
OKObeda Kailani
Obeda Kailani
HIHussein Ibrahim
Hussein Ibrahim
HGHakam Ghabra
Hakam Ghabra
Aim: To evaluate changes in corneal higher-order aberrations (HOAs) following epithelium-off accelerated corneal cross-linking (A-CXL) and to explore the impact on visual acuity. Methods: In this retrospective case series, 32 eyes of 24 patients with keratoconus (KC) underwent A-CXL. Treatment was delivered at 10 mW/cm2 for 9 min with a total dose of 5.4 J/cm2. The following anterior corneal HOAs: total corneal HOAs, trefoil, secondary trefoil, coma, secondary coma, secondary astigmatism and spherical aberrations were analysed using the Scheimpflug-Placido Sirius (CSO, Italy) corneal topographer at baseline and 12 months following treatment. Multivariate analysis was used to evaluate the independent effect of HOA subtypes on changes in uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA). Results: At one year post CXL, UDVA and CDVA were significantly improved, -0.13 ± 0.19 LogMAR (P = 0.0005) and -0.08 ± .0.11 LogMAR (P = 0.0003), respectively. The mean preoperative trefoil, secondary trefoil, secondary coma and secondary astigmatism were 0.95 ± 0.46; µm, 0.20 ± 0.11; µm, 0.29 ± 0.19; µm and 0.42 ± 0.17 µm, respectively. At one year, the mean values decreased significantly to 0.77 ± 0.47 µm, 0.15 ± 0.11 µm, 0.25 ± 0.18 µm and 0.34 ± 0.18 µm, respectively (P < 0.05, for all). No independent relationship between any HOA changes and change in UDVA was observed. A reduction in secondary coma aberration was associated with a change in CDVA (95% CI 0.01–1.34, P = 0.048; β = 0.67). Conclusion: A 9-min protocol of Accelerated corneal cross-linking is an effective treatment in improving corneal HOAs at 12 months follow up, in eyes with progressive keratoconus at one year follow-up. A change in secondary coma had a statistically significant and independent effect on CDVA.

1 January 2021 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
ASAbdelrahman Salman
Abdelrahman Salman
TDTaym Darwish
Taym Darwish
MGMarwan Ghabra
Marwan Ghabra
OKObeda Kailani
Obeda Kailani
HKHussam Khalil
Hussam Khalil
RSRafea Shaaban
Rafea Shaaban
Aim . To assess the efficacy and safety of accelerated corneal cross‐linking in the treatment of pediatric keratoconus. Method . In this retrospective case series, 29 eyes of 20 pediatric patients with keratoconus underwent accelerated corneal cross‐linking. Treatment was delivered at 10 mW/cm 2 for 9 minutes with a total dose of 5.4 J/cm 2 . Clinical evaluation included visual acuities and refractive and Scheimpflug corneal tomography assessments. All patients with a minimum follow‐up duration of 24 months were included in the study. Results . Mean ± standard deviation age was 15.41 ± 2.13 years (range: 8 to 18 years). Uncorrected distance visual acuity improved significantly from 0.56 ± 0.28 to 0.42 ± 0.29 logMAR ( P = 0.0003), and corrected distance visual acuity improved significantly from 0.34 ± 0.23 to 0.28 ± 0.22 logMAR ( P = 0.014). The mean manifest refraction spherical equivalent value was significantly reduced (−0.59 ± 0.95 D, P = 0.0024). While mean flat keratometry and steep keratometry values were not significantly altered ( P > 0.05 for both), the mean maximum keratometry value was significantly decreased from 56.97 ± 5.24 D preoperatively to 55.84 ± 5.37 D at 24 months postoperatively ( P = 0.003). Maximum keratometry had progressed by >1 D in two eyes (6.89%). Permanent corneal haze was reported in one case (3.44%). Conclusion . Our 24‐month follow‐up demonstrated that accelerated corneal cross‐linking appears to halt the progression of keratoconus in pediatric patients without apparent complications. Uncorrected and corrected distance visual acuities were also improved.

2 December 2022 in Tomography
Verified
Journal Article
Open access
PDF file
ASAbdelrahman Salman
Abdelrahman Salman
OKObeda Kailani
Obeda Kailani
JMJohn Marshall
John Marshall
MGMarwan Ghabra
Marwan Ghabra
ABAshraf Armia Balamoun
Ashraf Armia Balamoun
HAHala Alhaji
Hala Alhaji
Aim: To investigate the application of anterior and posterior corneal higher-order aberrations (HOAs) in detecting keratoconus (KC) and suspect keratoconus (SKC). Method: A retrospective, case-control study evaluating non-ectatic (normal) eyes, SKC eyes, and KC eyes. The Sirius Scheimpfug (CSO, Italy) analyses was used to measure HOAs of the anterior and posterior corneal surfaces. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Results: Two-hundred and twenty eyes were included in the analysis (normal n = 108, SKC n = 42, KC n = 70). Receiver operating characteristic (ROC) curve analysis revealed a high predictive ability for anterior corneal HOAs parameters: the root mean square (RMS) total corneal HOAs, RMS trefoil, and RMS coma to detect keratoconus (AUC > 0.9 for all). RMS Coma (3, ±1) derived from the anterior corneal surface was the parameter with the highest ability to discriminate between suspect keratoconus and normal eyes (AUC = 0.922; cut-off > 0.2). All posterior corneal HOAs parameters were unsatisfactory in discriminating between SKC and normal eyes (AUC < 0.8 for all). However, their ability to detect KC was excellent with AUC of >0.9 for all except RMS spherical aberrations (AUC = 0.846). Conclusions: Anterior and posterior corneal higher-order aberrations can differentiate between keratoconus and normal eyes, with a high level of certainty. In suspect keratoconus disease, however, only anterior corneal HOAs, and in particular coma-like aberrations, are of value. Corneal aberrometry may be of value in screening for keratoconus in populations with a high prevalence of the disease.

1 January 2025 in Journal of Ophthalmology
Verified
Journal Article
Open access
ASAbdelrahman Salman
Abdelrahman Salman
Mayank NanavatyMayank Nanavaty
Mayank Nanavaty
RORana Omran
Rana Omran
MGMarwan Ghabra
Marwan Ghabra
OKObeda Kailani
Obeda Kailani
OBOmar Badla
Omar Badla
Purpose: To evaluate the performance of the anterior segment optical coherence tomography (AS‐OCT) and Scheimpflug–Placido tomographic (SPT) indices in differentiating suspect keratoconus (SKC) from normal (N). Methods: In this cross‐sectional study, one eye of each patient was scanned on AS‐OCT and SPT. Following, 5 regression analysis models were developed: Model 1: combined AS‐OCT corneal thickness (CT); Model 2: combined AS‐OCT epithelial thickness (ET); Model 3: Models 1 + 2; Model 4: SPT indices (symmetry index front [SIf], symmetry index back [SIb], keratoconus vertex back [KVb], and minimum CT [ThkMin]); Model 5: Models 3 + 4. The areas under the curve (AUC) of receiver operator characteristic (ROC) curves were compared across groups to estimate their performance accuracy. Results: Two hundred and five N eyes, 56 SKC eyes, and 89 keratoconus (KC) eyes were scanned with AS‐OCT and SPT. For Models 1 and 2, no individual metric yielded an AUC > 0.84. For Model 3, the AUC was 0.96 (R2 Nagelkerke: 0.69) with 90.28% cases correctly identified as SKC. For Model 4, the AUC was 0.99 (R2 Nagelkerke: 0.87), with 95.58% of cases correctly classified as SKC. For Model 5, the diagnostic accuracy did not improve compared to Model 4. Conclusion: Both combined AS‐OCT indices and combined SPT indices provided excellent diagnostic power to differentiate SKC from N eyes. The combined SPT model showed a superior value compared to the AS‐OCT model. Furthermore, combined AS‐OCT and SPT data did not perform better than the combined SPT data alone.