Vladimir Prpic

Dr. Vladimir Prpic

Department of Fixed Prosthodontics, School of Dental Medicine, University of Zagreb, Zagreb, Zagreb, Grad, Croatia
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2020 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
Vladimir PrpicVladimir Prpic
Vladimir Prpic
ZSZdravko Schauperl
Zdravko Schauperl
AĆAmir Ćatić
Amir Ćatić
Nikša DulčićNikša Dulčić
Nikša Dulčić
SČSamir Čimić
Samir Čimić

1 June 2019 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Vladimir PrpicVladimir Prpic
Vladimir Prpic
ISIvan Slacanin
Ivan Slacanin
ZSZdravko Schauperl
Zdravko Schauperl
ACAmir Catic
Amir Catic
Nikša DulčićNikša Dulčić
Nikša Dulčić
SČSamir Čimić
Samir Čimić

18 August 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Vladimir PrpicVladimir Prpic
Vladimir Prpic
Filipa Špehar TomljenovićFilipa Špehar Tomljenović
Filipa Špehar Tomljenović
DŠDominik Štajdohar
Dominik Štajdohar
RBRoko Bjelica
Roko Bjelica
SČSamir Čimić
Samir Čimić
Matej ParMatej Par
Matej Par
Data regarding the mechanical properties of three-dimensionally (3D) printed materials for occlusal splint manufacturing are scarce. The aim of the present study was to evaluate the flexural strength and surface hardness of modern 3D-printed occlusal splint materials and compare them with two control groups, namely, milled and conventional cold-polymerized occlusal splint materials. A total of 140 rectangular specimens were manufactured for the present study. The specimens were prepared in accordance with the International Organization for Standardization standards (ISO 20795-1:2013). Five 3D-printed (NextDent Ortho Rigid, Dental LT Clear, Dentona Flexisplint, Cosmos Bite Splint, and ProArt Print Splint), one milled (ProArt CAD Splint), and one cold-polymerized (ProBase Cold) occlusal splint materials were used to determine flexural strength and surface hardness values. The three-point flexure test was used for the determination of flexural strength values, while Vickers hardness was measured to determine surface hardness. Ten specimens (n = 10) of each material were tested using these procedures. One-way ANOVA and Tukey’s post-hoc test were used to analyze the obtained results (α = 0.05). The values of flexural strength ranged from 46.1 ± 8.2 MPa to 106 ± 8.3 MPa. The Vickers hardness values ranged from 4.9 ± 0.5 VHN to 20.6 ± 1.3 VHN. Significant differences were found among the tested materials (p < 0.0001). The milled and cold-polymerized materials yielded higher values for both flexural strength (only one 3D-printed resin had comparable results to cold-polymerized acrylics) and surface hardness. There are differences in the mechanical properties of the various tested occlusal splint materials. The flexural strength of most of the 3D-printed materials and their surface hardness values are still inferior when compared to the milled or cold-polymerized materials.

1 January 2020 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
Vladimir PrpicVladimir Prpic
Vladimir Prpic
ZSZdravko Schauperl
Zdravko Schauperl
DGDOMAGOJ GLAVINA
DOMAGOJ GLAVINA
Amir CaticAmir Catic
Amir Catic
SČSamir Čimić
Samir Čimić
Prpić V, et al. J Adv Prosthodont. 2020 Dec;12(6):376-382. https://doi.org/10.4047/jap.2020.12.6.376

15 December 2016 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
IPIvona Posavec
Ivona Posavec
Vladimir PrpicVladimir Prpic
Vladimir Prpic
Dubravka Knezović ZlatarićDubravka Knezović Zlatarić
Dubravka Knezović Zlatarić
The purpose of this study was to evaluate and compare lightness (L), chroma (C) and hue (h), green-red (a) and blue-yellow (b) character of the color of maxillary right central incisors in different light conditions and light sources. Two examiners who were well trained in digital color evaluation participated in the research. Intraclass correlation coefficients (ICCs) were used to analyze intra- and interobserver reliability. The LCh and L*a*b* values were determined at 08.15 and at 10.00 in the morning under three different light conditions. Tooth color was assessed in 10 subjects using intraoral spectrophotometer VITA Easyshade Advance 4.0® set at the central region of the vestibular surface of the measured tooth. Intra- and interobserver ICC values were high for both examiners and ranged from 0.57 to 0.99. Statistically significant differences in LCh and L*a*b* values measured in different time of the day and certain light condition were not found (p>0.05). Statistically significant differences in LCh and L*a*b* values measured under three different light conditions were not found, too (p>0.05). VITA Easyshade Advance 4.0® is reliable enough for daily clinical work in order to assess tooth color during the fabrication of esthtic appliances because it is not dependent on light conditions and light sources.

1 March 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Vladimir PrpicVladimir Prpic
Vladimir Prpic
Amir CaticAmir Catic
Amir Catic
SKSonja Kraljevic
Sonja Kraljevic
LBLana Bergman
Lana Bergman
SČSamir Čimić
Samir Čimić
The data about bond strength between digitally produced denture base resins and artificial teeth are scarce. Several studies investigated shear bond strength values of milled denture base resins and different types of artificial teeth. The purpose of the present study was to compare and evaluate the available evidence through a systematic review. A bibliographic search was conducted in PubMed, Scopus, and Web of Science to assess adequate studies published up to 1 June 2022. This review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The appropriate studies that determined the shear bond strength values between milled denture base resins and artificial teeth were selected. The initial search identified 103 studies, which were included in the PRISMA 2020 flow diagram for new systematic reviews. Three studies met the inclusion criteria, and all of them present a moderate risk of bias (score 6). Two studies found no statistical differences between heat-polymerized and CAD/CAM (milled) denture base materials when attached with different types of artificial teeth, while one study showed higher values of CAD/CAM (milled) denture base materials. Bonding agents ensure bonding strength at least similar to the conventional methods. In order to improve the quality of future studies, it would be advantageous to use a larger number of specimens with standardized dimensions and a blinded testing machine operator to decrease the risk of bias.