Mohamed Roshdy Moussa

Dr. Mohamed Roshdy Moussa

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2024 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
AHAhmed Tawfik Hassan
Ahmed Tawfik Hassan
FBFahd A. Banakhr
Fahd A. Banakhr
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
ARAsmaa Fawzy Rashwan
Asmaa Fawzy Rashwan
MMMohamed Roshdy Moussa
Mohamed Roshdy Moussa
THTarek Hassan Mohamed Hassan
Tarek Hassan Mohamed Hassan
The negative impacts of microgrids (µGs) on the load frequency highlight the importance of implementing a robust, efficient, and adaptable controller to ensure stability. This work introduces an adaptive load frequency control (LFC) for an isolated µG that includes a PV system and electric vehicles (EVs), which have a significant impact on frequency. This control utilizes a combination of sine cosine optimization (SCO) and balloon effect identifier (BEI) algorithms. The controller presented in this work transforms the LFC process into an optimization problem that is highly compatible with various random situations encountered in the control process. The suggested control method is a novel approach by utilizing SCO+BEI for adaptive LFC application, resulting in a highly efficient response. The effectiveness of the proposed adaptive controller is assessed under the conditions of 17 MW variable load, system parameters uncertainties, and installed PV systems of 6 MW. MATLAB / Simulink package is rummage-sale as a digital test environment. According to simulation results, the proposed adaptive controller succeeds in regulating the frequency and power of an islanded µG. To measure the efficiency of the proposed control scheme, a comparison between other control techniques (such as adaptive controller using Jaya+BEI and classical integral controller) is done. The findings of the studied scenarios assured that the not compulsory control method using (SCO+BEI) has an obvious superiority over other control methods in terms of frequency solidity in case of random load instabilities and parameter uncertainties. Finally, it can be said that the proposed controller can better ensure the safe operation of the µGs.

24 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
ARAsmaa Fawzy Rashwan
Asmaa Fawzy Rashwan
YMYoussef Mobarak
Youssef Mobarak
DODina shaban Osheba
Dina shaban Osheba
Mahmoud Gamal HemeidaMahmoud Gamal Hemeida
Mahmoud Gamal Hemeida
Tomonobu SenjyuTomonobu Senjyu
Tomonobu Senjyu
MMMohamed Roshdy Moussa
Mohamed Roshdy Moussa
Single widespread employment of renewable energy sources (RESs) contributes to the shortage in the inertia of the microgrid (MG). After this, frequency stability may regress as a result of power imbalance or minor load fluctuations. This paper proposes an explicit adaptive modified virtual inertia control (VIC) based on an online Archimedes optimization algorithm (AOA) identifier for MG containing thermal, wind, and solar photovoltaic power plants. The Rung Kutta approach is used to construct the proposed online identifier, which acts as a model of the MG. AOA predicts the coefficients of the online identifier based on the input and output of MG to mimic the frequency deviation of the MG online. AOA estimates online the inertia and damping coefficients of the VIC system with an energy storage device based on online AOA identifier coefficients. The frequency deviation of the MG based on the proposed explicit adaptive modified VIC is compared with the conventional VIC based on fixed parameters and the VIC system based on optimal parameters using AOA offline under mutation in loads, weather-dependent input, and MG parameters using MATLAB/Simulink software. Furthermore, the proposed explicit adaptive modified VIC based on an online AOA identifier is evaluated with the adaptive VIC system based on fuzzy logic control, which adjusts only the inertial gain online. The simulation results demonstrate the capabilities of the proposed explicit adaptive modified VIC to improve the frequency stability and enhance low-inertia islanded MGs with RESs.