Acoustic microscopes and acoustic tweezers have great value in the application of microparticle manipulation, biomedical research and non-destructive testing. Ultrahigh frequency (UHF) ultrasonic transducers act as the key component in acoustic microscopes, and acoustic tweezers and acoustic lenses are essential parts of UHF ultrasonic transducers. Therefore, the preparation of acoustic lenses is crucial. Silicon is a suitable material for preparing acoustic lenses because of its high acoustic velocity, low acoustic attenuation and excellent machinability. In previous research, silicon lenses were mainly prepared by etching. However, etching has some drawbacks. The etching of large sizes is complex, time-consuming and expensive. Furthermore, vertical etching is preferred to spherical etching. Thus, a new method of ultra-precision machining was introduced to prepare silicon lenses. In this paper, silicon lenses with an aperture of 892 μm and a depth of 252 μm were prepared. Then, UHF ultrasonic transducers with a center frequency of 157 MHz and a −6-dB bandwidth of 52% were successfully prepared based on silicon lenses. The focal distance of the transducers was 736 μm and the F-number was about 0.82. The transducers had a lateral resolution of 11 μm and could distinguish the 13 μm slots on silicon wafers clearly.
1 April 2025 in IEEE Transactions on Instrumentation and Measurement
Ultrasonic attenuation affects the quality of ultrasonic imaging and material characterization significantly, especially at ultrahigh frequencies (>100 MHz), where higher attenuation bring about additional challenges. However, the reliable ultrasonic attenuation coefficients are scarce in this frequency range. In this study we propose a method of measuring ultrasound attenuation coefficient at ultrahigh frequencies. By the spectral analysis of multiple ultrasonic echoes ,the aggregate attenuation coefficient was extracted. Ultrasonic diffraction attenuation and transmission loss at the material interface are calibrated by using circular flat transducer acoustic fields and acoustic transmission line theory, respectively. The attenuation coefficient of silicon at approximately 150 MHz was measured to be 10.52 dB/cm. This article presents a novel approach for evaluating ultrasonic attenuation in the ultrahigh frequency range, reducing experimental errors and equipment costs. The proposed methodology also contributes to the development and characterization of ultrahigh frequency ultrasonic transducers.
Ultrahigh frequency (UHF) ultrasonic transducers are widely used in the fields of biomedical microscopy and nondestructive testing. However, the operating frequency and electro-acoustic conversion efficiency of UHF transducers have potential for further improvement. This work presents design, simulation, and fabrication of focused 300 MHz ultrahigh frequency (UHF) ultrasonic transducers. The UHF ultrasonic transducers were designed and simulated by equivalent circuit model and finite element analysis. Furthermore, the effect of lens aperture and ultrasonic frequency on the distribution of sound field were studied. To improve their performance, the UHF ultrasonic transducers were fabricated by using lithium niobate piezoelectric material and quartz glass focal lens. As a result, The pulse-echo measurements show the center frequency of the echoes were 238.7 MHz, 119.8 MHz and 73.1 MHz from the lens, near field and the focal point, respectively. According to the axial sound pressure distribution of the focusing transducer and the echoes, the ultrasound attenuation in water was calculated of 1.74 (± 0.16) × 10-3 × f2 (dB/cm). In addition, the image of 10 μm tungsten wire target illustrated the lateral and axial resolutions of the UHF ultrasonic transducers were 28.9 μm and 31.4 μm, respectively. This study highlights strategies for optimizing transducer performance and improving imaging resolution in Scanning Acoustic Microscopy (SAM) systems.
20 March 2026 in IEEE Transactions on Instrumentation and Measurement
High-frequency ultrasound imaging, due to its penetrability and micron-level resolution, is a critical modality for non-destructive testing (NDT) of integrated circuit (IC) packaging. However, the substantial acoustic impedance mismatch between the coupling medium (water) and the silicon substrate creates a severe measurement bottleneck: strong surface reflections drastically reduce the energy transmitted into the chip, degrading the signal-to-noise ratio (SNR) and resolution of internal interconnects. To overcome this physical limitation and enhance the measurement capability of scanning acoustic microscopy (SAM), we have designed a precise anti-reflection coating based on the theory of the evolution from electromagnetic transmission lines to acoustic transmission lines. By modeling the acoustic propagation path as an equivalent circuit, we designed and fabricated a three-layer composite structure (Parylene C/Au/Parylene C) specifically optimized for the particular frequency (70 MHz in this study). Experimental validation on commercial IC chips demonstrates that this "instrumentation conditioning" approach significantly improves signal integrity. Specifically, the coating yielded a 52% increase in the amplitude of internal echoes (from 142 mV to 216 mV). Furthermore, C-scan imaging revealed a 93% average improvement in the mean gradient of internal metal wires across multiple layers, enabling high-fidelity 3D reconstruction of interconnection structures that were previously indistinguishable from noise. This method offers a robust, low-cost solution to the intrinsic attenuation problem in high-frequency acoustic measurement, significantly extending the detection depth and clarity for IC reliability analysis.