Aljaž Čufar

Dr. Aljaž Čufar

Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana, Slovenia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2018 in Fusion Science and Technology
Verified
Journal Article
Closed access
AČAljaž Čufar
Aljaž Čufar
PBPaola Batistoni
Paola Batistoni
SCSean Conroy
Sean Conroy
ZGZamir Ghani
Zamir Ghani
ILIgor Lengar
Igor Lengar
JCJet Contributors
Jet Contributors
The fusion power output of fusion plasmas is measured using the neutron yield detectors due to its linear relation to the fusion yield. Absolutely calibrated neutron yield detectors are thus a crucial part of the plasma diagnostics system and the absolute accuracy of their calibration must be ensured. The transition of the Joint European Torus’s (JET’s) first wall material from carbon (C) wall to ITER-like (Be/W/C) first wall was a significant change in the structure of the machine and recalibration of the main neutron yield detectors was needed to maintain the required measurement uncertainty of less than ±10%. The neutron yield detectors were thus recalibrated through two in situ calibrations to deuterium-deuterium neutrons in 2013 and deuterium-tritium neutrons in 2017 using 252Cf spontaneous fission source and a compact neutron generator, respectively. We describe the extensive neutronics calculations performed in support of these latest calibration experiments. These analyses were performed using Monte Carlo simulations to better understand the calibration procedure, optimize the experiments, ensure personnel safety, and quantify the effects of the uncharacteristic circumstances during calibration experiments. This paper focuses on assessments of the effects of the uncharacteristic circumstances, e.g., the presence of the remote handling system in the machine due to its use in neutron source delivery, difference in the neutron emission spectrum, and differences in the neutron source shape. Lessons learned, findings, and relevance for calibrations of future large tokamaks are discussed.

1 November 2016 in Fusion Engineering and Design
Verified
Journal Article
Closed access
AČAljaž Čufar
Aljaž Čufar
ILIgor Lengar
Igor Lengar
IKIvan Kodeli
Ivan Kodeli
AMAlberto Milocco
Alberto Milocco
PSPatrick Sauvan
Patrick Sauvan
LSLuka Snoj
Luka Snoj

1 September 2019 in Fusion Engineering and Design
Verified
Journal Article
Open access
TFThomas Franke
Thomas Franke
PAPiero Agostinetti
Piero Agostinetti
CBChristian Bachmann
Christian Bachmann
ABAlessandro Bruschi
Alessandro Bruschi
MCMatthew Carr
Matthew Carr
SZShanliang Zheng
Shanliang Zheng

14 February 2017 in Fusion Science and Technology
Verified
Journal Article
Closed access
AČAljaž Čufar
Aljaž Čufar
BKBor Kos
Bor Kos
IKIvan Aleksander Kodeli
Ivan Aleksander Kodeli
ILIgor Lengar
Igor Lengar
ŽŠŽiga Štancar
Žiga Štancar
LSLuka Snoj
Luka Snoj
(2017). The Analysis of the External Neutron Monitor Responses in a Simplified JET-Like Tokamak Using ADVANTG. Fusion Science and Technology: Vol. 71, No. 2, pp. 162-176. doi: 10.13182/FST16-113

1 December 2020 in Fusion Engineering and Design
Verified
Journal Article
Closed access
PSPeter Spaeh
Peter Spaeh
CBChristian Bachmann
Christian Bachmann
RCRené Chavan
René Chavan
AČAljaž Čufar
Aljaž Čufar
TFThomas Franke
Thomas Franke
MTMinh Quang Tran
Minh Quang Tran

1 July 2020 in Fusion Engineering and Design
Verified
Journal Article
Closed access
SGSaul Garavaglia
Saul Garavaglia
BBBenedetta Baiocchi
Benedetta Baiocchi
ABAlessandro Bruschi
Alessandro Bruschi
AČAljaž Čufar
Aljaž Čufar
FFFrancesco Fanale
Francesco Fanale
MTMinh Quang Tran
Minh Quang Tran