Nashmin Yeganeh

Mrs. Nashmin Yeganeh

Engineering and Natural Sciences, University of Iceland, Reykjavík, Iceland
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2024 in Fluids
Verified
Journal Article
Open access
PDF file
Reza HassanianReza Hassanian
Reza Hassanian
Nashmin YeganehNashmin Yeganeh
Nashmin Yeganeh
MRMorris Riedel
Morris Riedel
This study proposes a computational model to define the wind velocity of the environment on the photovoltaic (PV) module via heat transfer concepts. The effect of the wind velocity and PV module is mostly considered a cooling effect. However, cooling and controlling the PV module temperature leads to the capability to optimize the PV module efficiency. The present study applied a nominal operating cell temperature (NOCT) condition of the PV module as a reference condition to determine the wind velocity and PV module temperature. The obtained model has been examined in contrast to the experimental heat transfer equation and outdoor PV module performance. The results display a remarkable matching of the model with experiments. The model’s novelty defines the PV module temperature in relation to the wind speed, PV module size, and various ambient temperatures that were not included in previous studies. The suggested model could be used in PV module test specification and provide analytical evaluation.

20 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Nashmin YeganehNashmin Yeganeh
Nashmin Yeganeh
IMIvan Makarov
Ivan Makarov
AKArni Kristjansson
Arni Kristjansson
RURunar Unnthorsson
Runar Unnthorsson
We examined discrimination accuracy of vibrotactile patterns on the upper forearm using a 2 × 3 array of voice coil actuators to generate 100 Hz vibrotactile stimulation. We evaluated participants’ ability to recognize distinct vibrotactile patterns presented both simultaneously (1000 ms) and sequentially (500 ms with a 450 ms interval). Recognition accuracy was significantly higher for sequential (93.24%) than for simultaneous presentation (26.15%). Patterns using 2–3 actuators were recognized more accurately than those using 4–5 actuators. During sequential presentation, there were primacy and recency effects; accuracy was higher for the initial and final stimulations in a sequence. Over time, participants also demonstrated a learning effect, becoming more adept at recognizing and interpreting vibrotactile patterns. This underscores the potential for skill development and emphasizes the value of training for wearable vibrotactile devices. We discuss the implications of these findings for the design of tactile communication devices and wearable technology.

28 May 2023 in Actuators
Verified
Journal Article
Open access
PDF file
Nashmin YeganehNashmin Yeganeh
Nashmin Yeganeh
IMIvan Makarov
Ivan Makarov
RURunar Unnthorsson
Runar Unnthorsson
AKArni Kristjansson
Arni Kristjansson
What are the effects of frequency variation of vibrotactile stimuli on localization acuity? The precise localization of vibrotactile stimuli is crucial for applications that are aimed at conveying vibrotactile information. In order to evaluate the ability to distinguish between vibrotactile stimuli based on their frequency and location on the forearm, we used a relative point localization method. Participants were presented with pairs of sequential vibrotactile stimuli at three possible locations on the forearm and asked to determine whether the second stimulation occurred at the same location as the first one in the pair or not. The stimulation frequency varied between 100 Hz, 150 Hz, 200 Hz and 250 Hz, which covers the range of frequencies that human observers are most sensitive to. The amplitude was kept constant. Our results revealed that the ability to discriminate between actuators remained unaffected by variations in the frequency of vibrotactile stimulation within the tested frequency range. The accuracy of the tactile discrimination task was heavily dependent on the location of the stimulation on the forearm, with the highest accuracy close to the wrist and elbow, locations that may serve as tactile anchor points. Our results highlight the critical role of stimulation location in precise vibrotactile localization and the importance of careful consideration of location in the design of forearm-mounted vibrotactile devices.

21 February 2022 in Thermo
Verified
Journal Article
Open access
PDF file
Reza HassanianReza Hassanian
Reza Hassanian
MRMorris Riedel
Morris Riedel
Asdis HelgadottirAsdis Helgadottir
Asdis Helgadottir
Nashmin YeganehNashmin Yeganeh
Nashmin Yeganeh
RURunar Unnthorsson
Runar Unnthorsson
This paper evaluates the photovoltaic (PV) module operating temperature’s relation to efficiency via a numerical heat transfer model. The literature reports that higher PV module operating temperatures impact PV module efficiency. There are dozens of explicit and implicit equations used to determine the PV module operating temperature. However, they are not universal, and for each application, it is necessary to insert a correction coefficient based on the environment and boundary conditions. Using a numerical method covering a more comprehensive range of PV module operation conditions to estimate a global equation, this study considers the solar radiation flux, Gt, solar ray direction with respect to the ground level, γ, convective heat transfer coefficient, h, tilt angle, β, ambient temperature, Ta, PV power output, Ppv, PV panel efficiency, η, and environmental properties. The results match the extant empirical work and related literature. PV module efficiency is found to have a linear relationship to the PV module operating temperature via a numerical heat transfer model corresponding to the well-known PV module. It specifies that heat transfer convection changes with PV module tilt angle, causing PV module operating temperature effects. It also represents the PV module operating temperature variations with ambient temperature and solar flux, like those reported in the literature.

24 November 2021 in Solar
Verified
Journal Article
Open access
PDF file
Reza HassanianReza Hassanian
Reza Hassanian
MRMorris Riedel
Morris Riedel
Nashmin YeganehNashmin Yeganeh
Nashmin Yeganeh
RURunar Unnthorsson
Runar Unnthorsson
In this study, recorded empirical data were applied with a practical approach to investigate the optimal tilt angle of the flat plate collectors facing south for a long period in Tehran, Iran. The data included 20 years of recorded average total radiation on the horizontal plane in Tehran’s meteorological station. Based on the previous studies, the annual optimum tilt angle for Tehran was estimated at 33 degrees annually; however, this estimation does not focus on the energy absorption and effectiveness of changing the tilt angle monthly, seasonally, and bi-annually via measured data. This paper aims to explain this distinction between various radiation receptions with different tilt angle adjustments. This study shows that annual solar cumulative radiation energy gained via a monthly tilt angle can be approximately 7% higher than that achieved with an annual tilt angle setup. Additionally, the seasonal and bi-annual tilt angles have about 6% more annual cumulative radiation absorption than the annual tilt angle setup. Moreover, with consideration of similar monthly received radiation, the results illustrate that the radiation gained with a monthly tilt angle set up was 20% greater in the summer months than an annual tilt angle adjustment.

18 September 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
MKMohammadmahdi Karimi
Mohammadmahdi Karimi
Nashmin YeganehNashmin Yeganeh
Nashmin Yeganeh
IMIvan Makarov
Ivan Makarov
ASAtli Örn Sverrisson
Atli Örn Sverrisson
KGKarl Fannar Gunnarsson
Karl Fannar Gunnarsson
RURunar Unnthorsson
Runar Unnthorsson
Systems presenting haptic information have emerged as an important technological advance in assisting individuals with sensory impairments or amputations, where the aim is to enhance sensory perception or provide sensory substitution through tactile feedback. These systems provide information on limb positioning, environmental interactions, and gait events, significantly improving mobility in amputees and their confidence about using such devices. This review summarizes recent progress in haptic feedback systems by providing a comparative analysis of different feedback approaches, evaluating their clinical effectiveness and usability, tactile feedback system design, and user experience, while identifying key gaps in the literature. These insights can contribute to the advancement of more effective, user-centered haptic feedback systems tailored for lower limb prosthetics. The findings are aimed at guiding future research in designing adaptive, intuitive, and clinically viable feedback mechanisms, fostering the widespread implementation of haptic systems in both assistive and rehabilitative applications.