We examined discrimination accuracy of vibrotactile patterns on the upper forearm using a 2 × 3 array of voice coil actuators to generate 100 Hz vibrotactile stimulation. We evaluated participants’ ability to recognize distinct vibrotactile patterns presented both simultaneously (1000 ms) and sequentially (500 ms with a 450 ms interval). Recognition accuracy was significantly higher for sequential (93.24%) than for simultaneous presentation (26.15%). Patterns using 2–3 actuators were recognized more accurately than those using 4–5 actuators. During sequential presentation, there were primacy and recency effects; accuracy was higher for the initial and final stimulations in a sequence. Over time, participants also demonstrated a learning effect, becoming more adept at recognizing and interpreting vibrotactile patterns. This underscores the potential for skill development and emphasizes the value of training for wearable vibrotactile devices. We discuss the implications of these findings for the design of tactile communication devices and wearable technology.
What are the effects of frequency variation of vibrotactile stimuli on localization acuity? The precise localization of vibrotactile stimuli is crucial for applications that are aimed at conveying vibrotactile information. In order to evaluate the ability to distinguish between vibrotactile stimuli based on their frequency and location on the forearm, we used a relative point localization method. Participants were presented with pairs of sequential vibrotactile stimuli at three possible locations on the forearm and asked to determine whether the second stimulation occurred at the same location as the first one in the pair or not. The stimulation frequency varied between 100 Hz, 150 Hz, 200 Hz and 250 Hz, which covers the range of frequencies that human observers are most sensitive to. The amplitude was kept constant. Our results revealed that the ability to discriminate between actuators remained unaffected by variations in the frequency of vibrotactile stimulation within the tested frequency range. The accuracy of the tactile discrimination task was heavily dependent on the location of the stimulation on the forearm, with the highest accuracy close to the wrist and elbow, locations that may serve as tactile anchor points. Our results highlight the critical role of stimulation location in precise vibrotactile localization and the importance of careful consideration of location in the design of forearm-mounted vibrotactile devices.
Systems presenting haptic information have emerged as an important technological advance in assisting individuals with sensory impairments or amputations, where the aim is to enhance sensory perception or provide sensory substitution through tactile feedback. These systems provide information on limb positioning, environmental interactions, and gait events, significantly improving mobility in amputees and their confidence about using such devices. This review summarizes recent progress in haptic feedback systems by providing a comparative analysis of different feedback approaches, evaluating their clinical effectiveness and usability, tactile feedback system design, and user experience, while identifying key gaps in the literature. These insights can contribute to the advancement of more effective, user-centered haptic feedback systems tailored for lower limb prosthetics. The findings are aimed at guiding future research in designing adaptive, intuitive, and clinically viable feedback mechanisms, fostering the widespread implementation of haptic systems in both assistive and rehabilitative applications.
While vibrotactile stimulation shows promise for sensory substitution devices, a crucial question concerns vibrotactile spatial resolution. We examined the optimum distance between three voice coil actuators (model: lofeltL5) on the forearm. Three actuators were embedded in a fabric-based vibrotactile sleeve where the actuators were placed in enclosures 3D-printed on the fabric. We used the relative point localization method where observers must discriminate whether two successive stimulations are in the same location or not. The resolution was measured for five vibrotactile sleeves, each with different distances between the actuators on the longitudinal axis of the forearm. The various distances were tested in a random order. In experiment one, pairs of stimuli were delivered sequentially in a random order to two adjacent actuators of the tactile sleeve on the upper side of the forearm. The task was to identify the perceived direction of the second stimulation (up, down, or the same) relative to the first one. Experiment two involved the same procedure but for the underside of the forearm. Taking the restrictions of the physical dimensions of the forearm and the design considerations into account, our results suggest that 20 mm is the optimum distance between the voice coil actuators (Model: Lofelt L5) for successful discrimination with high accuracy between the two stimulus locations on the forearm. There were no significant differences between the upper and undersides of the forearm.
22 January 2024 in Attention, Perception, & Psychophysics
When two brief vibrotactile stimulations are sequentially applied to observers’ lower back, there is systematic mislocalization of the stimulation: if the second stimulation is of higher intensity than the first one, observers tend to respond that the second stimulation was above the first one, and vice versa when weak intensity stimulation follows a strong one. This haptic mislocalization effect has been called the intensity order illusion . In the original demonstration of the illusion, frequency and amplitude of the stimulation were inextricably linked so that changes in amplitude also resulted in changes in frequency. It is therefore unknown whether the illusion is caused by changes in frequency, amplitude or both. To test this, we performed a multifactorial experiment, where we used L5 actuators that allow independent manipulation of frequency and amplitude. This approach enabled us to investigate the effects of stimulus amplitude, frequency and location, and to assess any potential interactions among these factors. We report four main findings: (1) we were able to replicate the intensity order illusion with the L5 tactors; (2) the illusion mainly occurred in the upwards direction, or in other words, when strong stimulation following a weaker one occurred above or in the same location as the first stimulation; (3) the illusion did not occur when similar stimulation patterns were applied in the horizontal direction; and (4) the illusion was solely due to changes in amplitude, whereas changes in frequency (100 Hz vs 200 Hz) had no effect.