Xin Yi

Dr. Xin Yi

Department of Clinical Pathology and Genomic Medicine, Houston Methodist Hospital, Weill Cornell Medical College, Houston, TX, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Journal of Clinical Investigation
Verified
Journal Article
Closed access
PDF file
ESEric Salazar
Eric Salazar
Suresh V. KuchipudiSuresh V. Kuchipudi
Suresh V. Kuchipudi
PCPaul A. Christensen
Paul A. Christensen
TETodd Eagar
Todd Eagar
XYXin Yi
Xin Yi
JMJames M. Musser
James M. Musser
The newly emerged severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) highlights the urgent need for assays that detect protective levels of neutralizing antibodies. We studied the relationship among anti-spike ectodomain (anti-ECD), anti–receptor-binding domain (anti-RBD) IgG titers, and SARS-CoV-2 virus neutralization (VN) titers generated by 2 in vitro assays using convalescent plasma samples from 68 patients with COVID-19. We report a strong positive correlation between both plasma anti-RBD and anti-ECD IgG titers and in vitro VN titers. The probability of a VN titer of ≥160, the FDA-recommended level for convalescent plasma used for COVID-19 treatment, was ≥80% when anti-RBD or anti-ECD titers were ≥1:1350. Of all donors, 37% lacked VN titers of ≥160. Dyspnea, hospitalization, and disease severity were significantly associated with higher VN titer. Frequent donation of convalescent plasma did not significantly decrease VN or IgG titers. Analysis of 2814 asymptomatic adults found 73 individuals with anti-ECD IgG titers of ≥1:50 and strong positive correlation with anti-RBD and VN titers. Fourteen of these individuals had VN titers of ≥1:160, and all of them had anti-RBD titers of ≥1:1350. We conclude that anti-RBD or anti-ECD IgG titers can serve as a surrogate for VN titers to identify suitable plasma donors. Plasma anti-RBD or anti-ECD titers of ≥1:1350 may provide critical information about protection against COVID-19 disease.

3 September 2025 in Clinical Chemistry
Verified
Journal Article
Closed access
JMJeffrey W Meeusen
Jeffrey W Meeusen
XYXin Yi
Xin Yi
SCSteven W Cotten
Steven W Cotten
JNJacob B Nielsen
Jacob B Nielsen
LDLeslie J Donato
Leslie J Donato
JCJing Cao
Jing Cao
Background: Direct measurement of low-density lipoprotein cholesterol (LDL-C) is widely used and recommended by professional society guidelines despite its potential limitations in patients with hypertriglyceridemia and low LDL-C. This study evaluated the performance of 3 direct LDL-C (LDL-CD) assays, 2 modern LDL-C calculation methods [LDL-C Martin (LDL-CM), LDL-C modified Sampson (LDL-CS)] and the conventional Friedewald (LDL-CF) method against the reference method, beta-quantification (LDL-CBQ). Methods: A total of 181 remnant sera from patients with standard lipid panel orders or from patients with LDL-CBQ orders with triglycerides (TG) ≥ 400 mg/dL (4.5 mmol/L), or with TG ≥ 150 mg/dL (1.69 mmol/L) and LDL-C < 70 mg/dL (1.8 mmol/L) were included. LDL-CD and lipid panel data were gathered from Abbott Alinity, Roche Cobas, and Siemens Atellica platforms. Results: LDL-CD among the 3 platforms showed a median CV of 11.2%. In patients with TG <400 mg/dL, LDL-CM and LDL-CS demonstrated less bias and less misclassification at the clinical decision LDL-C levels than LDL-CF or LDL-CD. In the 400 to 800 mg/dL (9.0 mmol/L) TG group, LDL-CS was superior to LDL-CD or LDL-CM in accuracy. When TG is ≥ 800 mg/dL, LDL-CD (Roche) showed substantial bias from LDL-CBQ while LDL-CS (Roche) showed smaller but significant bias. Conclusions: In summary, LDL-CD or LDL-CF showed little advantage over the 2 modern LDL-C calculation methods. LDL-CS showed the best overall correlation with LDL-CBQ and therefore is recommended to replace LDL-CF and potentially LDL-CD when making clinical decisions in patients with low LDL-C and hypertriglyceridemia.

5 June 2023 in Critical Reviews in Clinical Laboratory Sciences
Verified
Journal Article
Closed access
ZJZhicheng Jin
Zhicheng Jin
RBRoger L. Bertholf
Roger L. Bertholf
XYXin Yi
Xin Yi
Vitamin D has received significant attention from clinical societies, researchers, and the general population in recent years. While 25-hydroxyvitamin D (25(OH)D) is the most commonly-used biomarker of vitamin D status, 1α,25-dihydroxyvitamin D (1,25(OH)2D), its bioactive form, plays a critical role in regulating calcium and phosphorus homeostasis and is also involved in the immune system and cellular differentiation. Consequently, accurate measurements of 1,25(OH)2D can aid in the differential diagnosis of calcium-related disorders such as hypocalcemia in vitamin D-dependent rickets and hypercalcemia due to inappropriate increase of serum 1,25(OH)2D in granulomatous diseases. However, due to its lipophilicity and very low circulating concentration, the measurement of 1,25(OH)2D is particularly challenging. Over the past several decades, numerous efforts have been made to develop sensitive, specific, and practical laboratory methods for measuring 1,25(OH)2D. Methods using radioreceptor assay, radioimmunoassay, enzyme immunoassay, enzyme-linked immunosorbent assay, automated chemiluminescent immunoassay, and liquid chromatography-tandem mass spectrometry have been described. Each of these methods has unique advantages and limitations, and some are no longer used. Despite the sophisticated methods in use today, substantial variations between methods still exist. A concerted effort toward standardization of 1,25(OH)2D measurement is needed to ensure accurate and reliable results across laboratories and methods.

21 August 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
AGAbhinay Gontu
Abhinay Gontu
SSSreenidhi Srinivasan
Sreenidhi Srinivasan
ESEric Salazar
Eric Salazar
MNMeera Surendran Nair
Meera Surendran Nair
RNRuth Helmus Nissly
Ruth Helmus Nissly
VKVivek Kapur
Vivek Kapur
The optimal timeframe for donating convalescent plasma to be used for COVID-19 immunotherapy is unknown. To address this important knowledge deficit, we determined in vitro live-virus neutralizing capacity and persistence of IgM and IgG antibody responses against the receptor-binding domain and S1 ectodomain of the SARS-CoV-2 spike glycoprotein in 540 convalescent plasma samples obtained from 175 COVID-19 plasma donors for up to 142 days post-symptom onset. Robust IgM, IgG, and viral neutralization responses to SARS-CoV-2 persist, in the aggregate, for at least 100 days post-symptom onset. However, a notable acceleration in decline in virus neutralization titers ≥160, a value suitable for convalescent plasma therapy, was observed starting 60 days after first symptom onset. Together, these findings better define the optimal window for donating convalescent plasma useful for immunotherapy of COVID-19 patients and reveal important predictors of an ideal plasma donor, including age and COVID-19 disease severity score. One Sentence Summary: Evaluation of SARS-CoV-2 anti-spike protein IgM, IgG, and live-virus neutralizing titer profiles reveals that the optimal window for donating convalescent plasma for use in immunotherapy is within the first 60 days of symptom onset.

11 October 2021 in The Journal of Applied Laboratory Medicine
Verified
Journal Article
Closed access
ZJZhicheng Jin
Zhicheng Jin
RBRoger L Bertholf
Roger L Bertholf
XYXin Yi
Xin Yi
Background: The circulating concentration of 1α,25-dihydroxyvitamin D [1α,25(OH)2D] is very low, and the presence of multiple isomers may lead to inaccurate quantitation if not separated prior to analysis. Antibody-based immunoextraction procedures are sometimes used to remove structurally related isomers of 1α,25(OH)2D prior to an LC-MS/MS analysis. However, immunoextraction increases sample preparation time and cost. In addition, some dihydroxyvitamin D metabolites are not completely removed by immunoextraction. Method: We developed an HPLC method using a phenyl-hexyl column to investigate interfering isomers of 1α,25(OH)2D. Result: Using this method, 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD) derivatization product of 1α,25(OH)2D was found to be present as 2 epimers, which were separated chromatographically with an area ratio of 2:1. PTAD derivatized metabolite of 25-hydroxyvitamin D3 [i.e., 4β,25-dihydroxyvitamin D3 (4β,25(OH)2D3)] eluted out between 6R and 6S epimers of derivatized 1α,25(OH)2D3. If not chromatographically resolved, 4β,25(OH)2D can affect 1α,25(OH)2D quantitation. In a method comparison study, it was found that the presence of 4β,25(OH)2D produced positive bias up to 127% on 1α,25(OH)2D3 quantitation. Conclusion: The LC-MS/MS method we developed without an immunoextraction procedure was able to resolve the major interference peak from 1α,25(OH)2D and achieved reliable quantitation of 1α,25(OH)2D.

5 October 2020 in medRxiv
Verified
Preprint
Open access
PDF file
ESEric Salazar
Eric Salazar
PCPaul A. Christensen
Paul A. Christensen
EGEdward A. Graviss
Edward A. Graviss
DNDuc T. Nguyen
Duc T. Nguyen
BCBrian Castillo
Brian Castillo
JMJames M. Musser
James M. Musser
Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 remains a global threat with few proven efficacious treatments. Transfusion of convalescent plasma collected from donors who have recovered from COVID-19 disease has emerged as a promising therapy and has been granted emergency use authorization by the U.S. Food and Drug Administration (FDA). We recently reported results from interim analysis of a propensity-score matched study suggesting that early treatment of COVID-19 patients with convalescent plasma containing high titer anti-spike protein receptor binding domain (RBD) IgG significantly decreases mortality. We here present results from 60-day follow up of our cohort of 351 transfused hospitalized patients. Prospective determination of ELISA anti-RBD IgG titer facilitated selection and transfusion of the highest titer units available. Retrospective analysis by the Ortho VITROS IgG assay revealed a median signal/cutoff (S/C) ratio of 24.0 for transfused units, a value far exceeding the recently FDA-required cutoff of 12.0 for designation of high titer convalescent plasma. With respect to altering mortality, our analysis identified an optimal window of 44 hours post-hospitalization for transfusing COVID-19 patients with high titer convalescent plasma. In the aggregate, the analysis confirms and extends our previous preliminary finding that transfusion of COVID-19 patients soon after hospitalization with high titer anti-spike protein RBD IgG present in convalescent plasma significantly reduces mortality.