13 July 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KWKeith A. Wear
Keith A. Wear
CBChristian Baker
Christian Baker
PMPiero Miloro
Piero Miloro
Directivity is a hydrophone specification that describes response as a function of angle of incidence. The goal of this study was to compare, in the context of needle hydrophones, the commonly used rigid baffle model for hydrophone directivity to three alternative models: soft baffle, unbaffled (UB), and rigid piston (RP). Directivity measurements were performed at 1, 2, 3, 4, 6, 8, and 10 MHz from ±70° in two orthogonal planes for two ceramic and two polymer needle hydrophones with nominal geometrical sensitive element diameters of 200, 400, 600, and 1000 μm. Effective hydrophone sensitive element radius was estimated by least-squares fitting the four models to directivity measurement data using the sensitive element radius (a) as an adjustable parameter. For ka <; 4 (where k = 2π/λ and λ = wavelength), the RP model outperformed the other three models. For ka = 1, the average error in estimated sensitive element radius was 7% [95% confidence interval (CI): 3%-12%] for the RP model while the lowest average error by the other three models was 46% (95% CI: 38%-54%) for the UB model.

24 July 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KWKeith A. Wear
Keith A. Wear
CBChristian Baker
Christian Baker
PMPiero Miloro
Piero Miloro
It is important to know hydrophone frequency-dependent effective sensitive element size in order to account for spatial averaging artifacts in acoustic output measurements. Frequency-dependent effective sensitive element size may be obtained from hydrophone directivity measurements. Directivity was measured at 1, 2, 3, 4, 6, 8, and 10 MHz from ±60° in two orthogonal planes for eight membrane hydrophones with nominal geometrical sensitive element radii (a g ) ranging from 100 to 500 μm. The mean precision of directivity measurements (obtained from four repeated measurements at each frequency and angle) averaged over all frequencies, angles, and hydrophones was 5.8%. Frequency-dependent effective hydrophone sensitive element radii a eff (f) were estimated by fitting the theoretical directional response for a disk receiver to directivity measurements using the sensitive element radius (a) as an adjustable parameter. For the eight hydrophones in aggregate, the relative difference between effective and geometrical sensitive element radii, (a eff - a g )/a g , was fit to C/(ka g ) n , where k = 2π/λ and λ = wavelength. The functional fit yielded C = 1.89 and n = 1.36. The root mean square difference between the data and the model was 34%. It was shown that for a given value for a g , a eff (f) for membrane hydrophones far exceeds that for needle hydrophones at low frequencies (e.g., c4 MHz when a g = 100 μm). This empirical model for a eff (f) provides information required for the compensation of spatial averaging artifacts in acoustic output measurements and is useful for choosing an appropriate sensitive element size for a given experiment.

13 November 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KWKeith A. Wear
Keith A. Wear
ASAnant Shah
Anant Shah
AIAoife M. Ivory
Aoife M. Ivory
CBChristian Baker
Christian Baker
This article reports the experimental validation of a method for correcting underestimates of peak compressional pressure (${p}_{c}{)}$ , peak rarefactional pressure (${p}_{r}{)}$ , and pulse intensity integral (pii) due to hydrophone spatial averaging effects that occur during output measurement of clinical linear and phased arrays. Pressure parameters (${p}_{c}$ , ${p}_{r}$ , and pii), which are used to compute acoustic exposure safety indexes, such as mechanical index (MI) and thermal index (TI), are often not corrected for spatial averaging because a standardized method for doing so does not exist for linear and phased arrays. In a companion article (Part I), a novel, analytic, inverse-filter method was derived to correct for spatial averaging for linear or nonlinear pressure waves from linear and phased arrays. In the present article (Part II), the inverse filter is validated on measurements of acoustic radiation force impulse (ARFI) and pulsed Doppler waveforms. Empirical formulas are provided to enable researchers to predict and correct hydrophone spatial averaging errors for membrane-hydrophone-based acoustic output measurements. For example, for a 400-$\mu \text{m}$ membrane hydrophone, inverse filtering reduced errors (means ± standard errors for 15 linear array/hydrophone pairs) from about 34% (${p}_{c}{)}$ , 22% (${p}_{r}{)}$ , and 45% (pii) down to within 5% for all three parameters. Inverse filtering for spatial averaging effects significantly improves the accuracy of estimates of acoustic pressure parameters for ARFI and pulsed Doppler signals.

10 July 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KWKeith A. Wear
Keith A. Wear
ASAnant Shah
Anant Shah
CBChristian Baker
Christian Baker
This article reports an investigation of an inverse-filter method to correct for experimental underestimation of pressure due to spatial averaging across a hydrophone sensitive element. The spatial averaging filter (SAF) depends on hydrophone type (membrane, needle, or fiber-optic), hydrophone geometrical sensitive element diameter, transducer driving frequency, and transducer F number (ratio of focal length to diameter). The absolute difference between theoretical and experimental SAFs for 25 transducer/hydrophonepairs was 7% ± 3% (mean ± standard deviation). Empirical formulas based on SAFs are provided to enable researchers to easily correct for hydrophone spatial averaging errors in peak compressional pressure (ρ c ), peak rarefactional pressure (ρ r ), and pulse intensity integral. The empirical formulas show, for example, that if a 3-MHz, F/2 transducer is driven to moderate nonlinear distortion and measured at the focal point with a 500-μm membrane hydrophone, then spatial averaging errors are approximately 16% (ρ c ), 12% (ρ r ), and 24% (pulse intensity integral). The formulas are based on circulartransducersbut also provide plausible upper bounds for spatial averaging errors for transducers with rectangular-transmit apertures, such as linear and phased arrays.

22 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CBChristian Baker
Christian Baker
MXMiguel Xochicale
Miguel Xochicale
FLFang-Yu Lin
Fang-Yu Lin
SMSunish Mathews
Sunish Mathews
FJFrancois Joubert
Francois Joubert
Wenfeng XiaWenfeng Xia
Wenfeng Xia
Ultrasound is an essential tool for guidance of many minimally-invasive surgical and interventional procedures, where accurate placement of the interventional device is critical to avoid adverse events. Needle insertion procedures for anaesthesia, fetal medicine and tumour biopsy are commonly ultrasound-guided, and misplacement of the needle may lead to complications such as nerve damage, organ injury or pregnancy loss. Clear visibility of the needle tip is therefore critical, but visibility is often precluded by tissue heterogeneities or specular reflections from the needle shaft. This paper presents the in vitro and ex vivo accuracy of a new, real-time, ultrasound needle tip tracking system for guidance of fetal interventions. A fibre-optic, Fabry-Pérot interferometer hydrophone is integrated into an intraoperative needle and used to localise the needle tip within a handheld ultrasound field. While previous, related work has been based on research ultrasound systems with bespoke transmission sequences, the new system—developed under the ISO 13485 Medical Devices quality standard—operates as an adjunct to a commercial ultrasound imaging system and therefore provides the image quality expected in the clinic, superimposing a cross-hair onto the ultrasound image at the needle tip position. Tracking accuracy was determined by translating the needle tip to 356 known positions in the ultrasound field of view in a tank of water, and by comparison to manual labelling of the the position of the needle in B-mode US images during an insertion into an ex vivo phantom. In water, the mean distance between tracked and true positions was 0.7 ± 0.4 mm with a mean repeatability of 0.3 ± 0.2 mm. In the tissue phantom, the mean distance between tracked and labelled positions was 1.1 ± 0.7 mm. Tracking performance was found to be independent of needle angle. The study demonstrates the performance and clinical compatibility of ultrasound needle tracking, an essential step towards a first-in-human study.

12 July 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
BZBajram Zeqiri
Bajram Zeqiri
CBChristian Baker
Christian Baker
GAGiuseppe Alosa
Giuseppe Alosa
PWPeter N T Wells
Peter N T Wells
HLHai-Dong Liang
Hai-Dong Liang
The principle of using ultrasonic computed tomography (UCT) clinically for mapping tissue acoustic properties was suggested almost 40 years ago. Despite strong research activity, UCT been unable to rival its x-ray counterpart in terms of the ability to distinguish tissue pathologies. Conventional piezoelectric detectors deployed in UCT are termed phase-sensitive (PS) and it is well established that this property can lead to artefacts related to refraction and phase-cancellation that mask true tissue structure, particularly for reconstructions involving attenuation. Equally, it has long been known that phase-insensitive (PI) detectors are more immune to this effect, although sufficiently sensitive devices for clinical use have not been available. This paper explores the application of novel PI detectors to UCT. Their operating principle is based on exploiting the pyroelectric properties of the piezoelectric polymer polyvinylidene difluoride. An important detector performance characteristic which makes it particularly suited to UCT, is the lack of directionality of the PI response, relative to the PS detector mode of operation. The performance of the detectors is compared to conventional PS detection methods, for quantitatively assessing the attenuation distribution within various test objects, including a two-phase polyurethane phantom. UCT images are presented for a range of single detector apertures; tomographic reconstruction images being compared with the known structure of phantoms containing inserts as small as 3 mm, which were readily imaged. For larger diameter inserts (>10 mm), the transmitter–detector combination was able to establish the attenuation coefficient of the insert to within ±10% of values determined separately from plane-wave measurements on representative material plaques. The research has demonstrated that the new PI detectors are significantly less susceptible to refraction and phase-cancellation artefacts, generating realistic images in situations where conventionally-employed through-transmission PS detection techniques were unable to do so. The implications of the study to the potential screening of breast disease are discussed.