Dimitrios Sokratis Komaris

Dr. Dimitrios Sokratis Komaris

University College Cork
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MMMatteo Menolotto
Matteo Menolotto
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
STSalvatore Tedesco
Salvatore Tedesco
BOBrendan O'Flynn
Brendan O'Flynn
MWMichael Walsh
Michael Walsh
The rapid technological advancements of Industry 4.0 have opened up new vectors for novel industrial processes that require advanced sensing solutions for their realization. Motion capture (MoCap) sensors, such as visual cameras and inertial measurement units (IMUs), are frequently adopted in industrial settings to support solutions in robotics, additive manufacturing, teleworking and human safety. This review synthesizes and evaluates studies investigating the use of MoCap technologies in industry-related research. A search was performed in the Embase, Scopus, Web of Science and Google Scholar. Only studies in English, from 2015 onwards, on primary and secondary industrial applications were considered. The quality of the articles was appraised with the AXIS tool. Studies were categorized based on type of used sensors, beneficiary industry sector, and type of application. Study characteristics, key methods and findings were also summarized. In total, 1682 records were identified, and 59 were included in this review. Twenty-one and 38 studies were assessed as being prone to medium and low risks of bias, respectively. Camera-based sensors and IMUs were used in 40% and 70% of the studies, respectively. Construction (30.5%), robotics (15.3%) and automotive (10.2%) were the most researched industry sectors, whilst health and safety (64.4%) and the improvement of industrial processes or products (17%) were the most targeted applications. Inertial sensors were the first choice for industrial MoCap applications. Camera-based MoCap systems performed better in robotic applications, but camera obstructions caused by workers and machinery was the most challenging issue. Advancements in machine learning algorithms have been shown to increase the capabilities of MoCap systems in applications such as activity and fatigue detection as well as tool condition monitoring and object recognition.

4 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MSMarco Sica
Marco Sica
STSalvatore Tedesco
Salvatore Tedesco
CCColum Crowe
Colum Crowe
LKLorna Kenny
Lorna Kenny
KMKevin Moore
Kevin Moore
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
Parkinson’s disease (PD) is a progressive neurological disorder of the central nervous system that deteriorates motor functions, while it is also accompanied by a large diversity of non-motor symptoms such as cognitive impairment and mood changes, hallucinations, and sleep disturbance. Parkinsonism is evaluated during clinical examinations and appropriate medical treatments are directed towards alleviating symptoms. Tri-axial accelerometers, gyroscopes, and magnetometers could be adopted to support clinicians in the decision-making process by objectively quantifying the patient’s condition. In this context, at-home data collections aim to capture motor function during daily living and unobstructedly assess the patients’ status and the disease’s symptoms for prolonged time periods. This review aims to collate existing literature on PD monitoring using inertial sensors while it focuses on papers with at least one free-living data capture unsupervised either directly or via videotapes. Twenty-four papers were selected at the end of the process: fourteen investigated gait impairments, eight of which focused on walking, three on turning, two on falls, and one on physical activity; ten articles on the other hand examined symptoms, including bradykinesia, tremor, dyskinesia, and motor state fluctuations in the on/off phenomenon. In summary, inertial sensors are capable of gathering data over a long period of time and have the potential to facilitate the monitoring of people with Parkinson’s, providing relevant information about their motor status. Concerning gait impairments, kinematic parameters (such as duration of gait cycle, step length, and velocity) were typically used to discern PD from healthy subjects, whereas for symptoms’ assessment, researchers were capable of achieving accuracies of over 90% in a free-living environment. Further investigations should be focused on the development of ad-hoc hardware and software capable of providing real-time feedback to clinicians and patients. In addition, features such as the wearability of the system and user comfort, set-up process, and instructions for use, need to be strongly considered in the development of wearable sensors for PD monitoring.

25 October 2019 in IEEE Access
Verified
Journal Article
Open access
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
EPEduardo Perez-Valero
Eduardo Perez-Valero
LJLuke Jordan
Luke Jordan
JBJohn Barton
John Barton
LHLiam Hennessy
Liam Hennessy
STSalvatore Tedesco
Salvatore Tedesco

19 February 2022 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
GTGeorgia Tarfali
Georgia Tarfali
BOBrendan O’fLynn
Brendan O’fLynn
STSalvatore Tedesco
Salvatore Tedesco
Background: The benefits to be obtained from home-based physical therapy programmes are dependent on the proper execution of physiotherapy exercises during unsupervised treatment. Wearable sensors and appropriate movement-related metrics may be used to determine at-home exercise performance and compliance to a physical therapy program.Methods: A total of thirty healthy volunteers (mean age of 31 years) had their movements captured using wearable inertial measurement units (IMUs), after video recordings of five different exercises with varying levels of complexity were demonstrated to them. Participants were then given wearable sensors to enable a second unsupervised data capture at home. Movement performance between the participants’ recordings was assessed with metrics of movement smoothness, intensity, consistency and control.Results: In general, subjects executed all exercises similarly when recording at home and as compared with their performance in the lab. However, participants executed all movements faster compared to the physiotherapist’s demonstrations, indicating the need of a wearable system with user feedback that will set the pace of movement.Conclusion: In light of the Covid-19 pandemic and the imperative transition towards remote consultation and tele-rehabilitation, this work aims to promote new tools and methods for the assessment of adherence to home-based physical therapy programmes. The studied IMU-derived features have shown adequate sensitivity to evaluate home-based programmes in an unsupervised manner. Cost-effective wearables, such as the one presented in this study, can support therapeutic exercises that ought to be performed with appropriate speed, intensity, smoothness and range of motion.

8 September 2022 in IEEE Access
Verified
Journal Article
Open access
STSalvatore Tedesco
Salvatore Tedesco
OTOscar Manzano Torre
Oscar Manzano Torre
MBMarco Belcastro
Marco Belcastro
PTPasqualino Torchia
Pasqualino Torchia
DADavide Alfieri
Davide Alfieri
BOBrendan O'Flynn
Brendan O'Flynn
Smart wearables are a promising tool for the objective and quantifiable monitoring of patients’ capabilities during remote at-home assessments. A novel platform for the remote assessment of patients undergoing knee rehabilitation has been presented in this paper, SKYRE. The challenges associated with the design of the SKYRE platform are described. The platform consists of a multi-sensor wearable garment and an associated ICT architecture, with the aim of capturing real-time objective assessment of physical rehabilitation exercises and support clinicians in their decision-making process as well as provide guidance to the end-users so as to increase their awareness and compliance. The overall system architecture is defined based on users’ requirements and industrial design, and both hardware and software platforms have been thoroughly discussed in detail, including electronic design, textile integration, prototyping process, and firmware development, as well as the mobile application and web portal implementation. Multiple sensing technologies are adopted, including motion capture, electromyography measurements, and muscle electro-stimulation. The developed system, SKYRE, meets the end-users’ requirements, and the validation shows that the system presents results comparable to gold-standard technologies. SKYRE therefore might represent a valid alternative for patients and clinicians willing to perform a remote objective assessment of the rehabilitation process following knee surgery.

16 December 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
LKLiudmila Khokhlova
Liudmila Khokhlova
DKDimitrios Sokratis Komaris
Dimitrios Sokratis Komaris
STSalvatore Tedesco
Salvatore Tedesco
BOBrendan O'FLynn
Brendan O'FLynn
Objectives: Population ageing and the subsequent increase of joint disorders prevalence requires the development of non-invasive and early diagnostic methods to enable timely medical assistance and promote healthy aging. Over the last decades, acoustic emission (AE) monitoring, a technique widely used in non-destructive testing, has also been introduced in orthopedics as a diagnostic tool. This review aims to synthesize the literature on the use of AE monitoring for the assessment of hip and knee joints or implants, highlighting the practical aspects and implementation considerations. Methods: this review was conducted as per the PRISMA statement for scoping reviews. All types of studies, with no limits on date of publication, were considered. Articles were assessed and study design parameters and technical characteristics were extracted from relevant studies. Results: conducted search identified 1379 articles and 64 were kept for charting. Seven additional articles were added at a later stage. Reviewed works were grouped into studies on joint condition assessment, implant assessment, and hardware or software development. Native knees and hip implants were most commonly assessed. The most researched conditions were osteoarthritis, implant loosening or squeaking in vivo and structural damage of implants in vitro. Conclusion: in recent years, AE monitoring showed potential of becoming a useful diagnostic tool for lower limb pathologies. However, further research is needed to refine the existing methods and assess their feasibility in early diagnostics. Significance: The current state of research on AE monitoring for hip and knee joint assessment is described and future research directions are identified.