The higher voltage blocking capability and faster switching speed of SiC MOSFETs has the potential to replace Si IGBTs in medium/low-voltage and high-power applications. In this paper, a state-of-the-art 325A, 1700V SiC MOSFET module has been fully characterized under various load currents, bus voltages and gate resistances to reveal their switching capability. Meanwhile, Si IGBT modules with similar power ratings are also tested under the same conditions. From the test results, several interesting points have been obtained: for example, the over-shoot current of the SiC MOSFET module is greater than that of the Si IGBT module when the load current is high although a SiC Schottky diode is used in the SiC MOSFET module and a PIN diode is used in the IGBT module and a circuit model to explain this phenomenon has been proposed in this paper; the induced negative gate voltage due to the complementary device turn-off (cross-talk effect) is more harmful to the SiC MOSFET module than the induced positive gate voltage during turn-on when the gate off-voltage is -6V. An accurate power loss model which is suitable for a three-phase two-level converter based on SiC MOSFET modules been presented and verified in this paper.
13 June 2018 in IEEE Transactions on Industrial Electronics
Modular multilevel converters (MMCs) have been widely used in recent years due to their superior advantages in medium/high-voltage applications. The finite control set model predictive control (FCS-MPC) has shown high dynamic responses for the control of the MMC. However, with the existing FCS-MPC algorithms, the steady-state performances are degraded due to the irregular pulse patterns, especially under unbalanced grid conditions. In this paper, based on the discrete state-space model of the MMC, a modulated MPC (M2PC) algorithm is proposed to overcome the aforementioned drawback of the FCS-MPC. Compared to FCS-MPC algorithms, the M2PC accurately calculates and tracks the reference circulating current and adopts an effective modulation method, and, in turn, the proposed M2PC can obtain enhanced steady-state ac-side/circulating currents control performances under unbalanced grid conditions, with the high dynamic-state performances of the conventional FCS-MPC algorithms reserved. Experimental results regarding one typical FCS-MPC algorithm and the proposed M2PC algorithm are comparatively evaluated in detail for the steady/dynamic-state performances and pulse patterns by a downscaled prototype. The effectiveness and feasibility of the proposed M2PC are clearly validated by the experimental results.
13 December 2018 in IEEE Transactions on Industrial Electronics
Cascaded H-bridge (CHB) multilevel converters are promising candidates for large-scale grid-connected photovoltaic systems (megawatt to gigawatt). However, the conventional CHB multilevel converter cannot ensure the inter-module and inter-phase power balance, resulting in imbalanced grid currents. Therefore, in this paper, a new topology consisting of CHB multilevel converters and interleaved-boost full-bridge LLC (IB-FBLLC)-based three-port dc-dc isolation converters is proposed. In this proposed topology, a common dc bus made up of the low-voltage-side ports of IB-FBLLC-based three-port dc-dc converters can completely solve the inherent power imbalance issues. Moreover, the design parameters of dc-dc converters considering the minimization of the input current ripple and optimization of switching frequency range are discussed in detail. Simulation results of the three-phase system and experimental results of the single-phase system clearly verify the effectiveness and feasibility of the proposed topology and control strategies.
8 January 2021 in IEEE Transactions on Industrial Electronics
Virtual space vector pulsewidth modulation (VSVPWM) provides a new approach to neutral point voltage (NPV) control and common mode voltage (CMV) suppression. Few values of coefficients configured in the virtual vectors cannot adjust the NPV continuously. An improved VSVPWM (IVSVPWM) with active neutral point voltage control (ANPVC) and CMV suppression is proposed in this article. Continuously variable coefficients configured in the virtual vectors adjust the NPV actively and continuously for any load power factor over the full modulation indexes. Failure of CMV suppression is analyzed, and the undesired vectors with high CMV are avoided by limiting the range of the variable coefficients. The limited variable coefficients and the selected basic vectors with low CMV suppress the CMV effectively. Simulation and experimental results are given to validate the proposed novel IVSVPWM, which can achieve quicker ANPVC and reduce CMV to half of the conventional VSVPWM simultaneously.
1 November 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The point of common coupling (PCC) voltage feedforward control is widely employed for LCL-type grid-connected converters to prevent large inrush current during startup, reduce steady-state tracking error, and suppress disturbances of grid voltage. Generally, this feedforward loop is ignored in the system modeling and stability analysis for simplicity. However, the grid impedance would be introduced to the control system through the feedforward loop under practical power grids, leading to a different current loop model from the original one, then conventional LCL filter design for single-current-loop control may be inappropriate. In this paper, the detailed modeling of current control loop with unit PCC voltage feedforward is presented. Based on the established model, it is found that unstable open-loop poles may appear under grid impedance variation, which thus may cause system instability. Therefore, the robust design regions of LCL filters against grid impedance variation are proposed for single-current-loop control schemes. Moreover, another interesting finding is that the feedforward control can help maintain a high current control bandwidth under grid impedance variation. This feature is highly desirable if multiple resonant controllers are employed for harmonic compensation. Experimental results are finally presented to verify the theoretical analysis and robust design presented in this paper.
9 November 2017 in IEEE Transactions on Power Electronics
Coil misalignment in inductively coupled power transfer (ICPT) systems will lead to fluctuation of transferred power, and even instability of the ICPT systems. To obtain robust control for ICPT system with coil misalignment, a $\mu$-controller based on structured singular value (SSV) is used to set up a closed-loop system in this paper. A generalized state-space averaging (GSSA) model is established using GSSA method first. Then a standard M-$\Delta$ configuration is obtained by a linear fractional transformation (LFT) of the nominal and uncertainty parts of the GSSA model. Finally a $\mu$-controller is designed by D-K iteration. Besides, the theoretical results are validated by computer simulations and practical experiments.