Filippo Pepe

Dr. Filippo Pepe

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2025 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Open access
NANiki Arveda
Niki Arveda
MCMarta Calza
Marta Calza
TCTommaso Castroflorio
Tommaso Castroflorio
FGFrancesco Garino
Francesco Garino
Antonella GiancottiAntonella Giancotti
Antonella Giancotti
GSGiuseppe Siciliani
Giuseppe Siciliani
This study aimed to establish a consensus, thanks to the participation of a large group of experts in the field of aligner therapy, on several of its clinical and extraclinical aspects, with particular reference to its potential and biomechanical limitations. A Delphi study was conducted in 3 rounds. On the basis of the most recent systematic reviews in the literature, the steering committee formulated 35 questions. A group of 36 international experts agreed to participate in the survey and were asked to respond to the questions, choosing their level of agreement on a scale of 1-5 in the first round, then from 1 to 3 in the second, and finally with a yes or no response in the third, progressively narrowing the field of research. The items for which consensus (≥70%) was obtained were accepted; the others were reformulated. On the basis of the analysis of the experts' responses, 68 questions were reformulated for the second round and 28 for the third round. After 3 rounds, the study generated 47 consensus statements regarding biomechanical aspects and extraclinical factors. The study, based on the modified Delphi method, collected the opinion of experts, comparing it with the scientific literature to evaluate the potential and limitations of orthodontic aligners, obtaining 47 consensus statements related to biomechanics and extraclinical factors.

6 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FCFrancesca Cremonini
Francesca Cremonini
Giuseppe ChiusoloGiuseppe Chiusolo
Giuseppe Chiusolo
FPFilippo Pepe
Filippo Pepe
LLLuca Lombardo
Luca Lombardo
Patient compliance remains a significant challenge in orthodontic treatment with clear aligners, as adherence to prescribed wear time is often suboptimal. This study investigated the potential of colorimetric analysis as a method to assess compliance with NOXI 3D-printed night-time aligners. Specifically, it evaluated color variations in polyamide aligners due to thermo-oxidation, using the RGB (Red, Green, Blue) color model as a non-invasive indicator. In total, 10 patients participated in this prospective study, wearing aligners for either 7 or 12 h daily over a 14-day period. Colorimetric measurements were collected via a smartphone-based application, and statistical analyses examined correlations between wear duration and color changes. The results revealed a significant association between a longer wear time and increased discoloration (p < 0.001), supporting the feasibility of RGB-based monitoring as a reliable compliance tool. However, individual variability in saliva composition, diet, and oral hygiene may have influenced the results, highlighting the need for further research into potential confounding variables. These findings underscore the promise of integrating digital monitoring technologies to improve adherence tracking and patient management in orthodontics. Future studies should refine the methodology and validate its efficacy in larger, more diverse populations.

27 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
EPEnzo Pasciuti
Enzo Pasciuti
DGDaniela Guiducci
Daniela Guiducci
FGFilippo Guidorizzi
Filippo Guidorizzi
TTTecla Terenzio
Tecla Terenzio
SAVERIO CERAULOSAVERIO CERAULO
SAVERIO CERAULO
LLLuca Lombardo
Luca Lombardo
(1) Aim: To compare transverse dimensions measured on AI-generated intra-oral models and conventional digital intra-oral models. (2) Methods: A group of 38 patients treated with clear aligners was selected retrospectively from those whose records featured both AI-generated and conventional digital intra-oral models taken at the same timepoint. Transverse dimensions (inter-canine, inter-premolar, and inter-molar distances) on both upper and lower arches were evaluated and compared. Intra-class correlation index and paired t-test were applied to test the repeatability of measurements and statistically significant differences, respectively. Statistical significance was set at 0.05. (3) Results: Intra-class correlation index showed good repeatability. Paired t-test showed differences in measurements of the distances between the thicket area of gingiva on the palatal side of the upper first molar (p = 0.002), the gingival margin of the lower first molar (p = 0.014), and the mesio-vestibular cusps of the lower first molars (p = 0.019). (4) Conclusions: Transverse measurements were similar on AI-generated and conventional intra-oral .stl renderings. Statistical differences were found on posterior areas of both upper and lower dental arches, but are unlikely to be clinically significant.

9 May 2025 in Sci
Verified
Journal Article
Open access
PDF file
MPMario Palone
Mario Palone
DTDavide Tucci
Davide Tucci
MCMarta Calza
Marta Calza
NANiki Arveda
Niki Arveda
FCFrancesca Cremonini
Francesca Cremonini
LLLuca Lombardo
Luca Lombardo
Background: This study aims to investigate the biomechanical characteristics of orthodontic miniscrews manufactured for use in infrazygomatic crests. Methods: This study analyzed the Zygomatic Spider Screw (HDC, Thiene, Italy), considering four variables: length, insertion angle, insertion depth, support thickness. Twenty-two configurations were tested on 66 miniscrews, all with a diameter of 2 mm, and were inserted into D1 bone-like supports. After compression tests, the deformation angles and linear distances between the tips of the miniscrews were measured. Results: Power analysis showed 99% power for the deformation angles and linear distance. The ICC indicated the good repeatability of the results, with values above 0.70. The mean maximum load values ranged from 21.5 N to 228.8 N, while the mean deformations ranged from 0.45 mm to 2.26 mm. Miniscrews with greater insertion depths (6 and 8 mm) exhibited approximately twice the average deformation (1.5 mm) compared to those inserted at 2 and 4 mm (0.71 mm). It was noted that miniscrews with higher deformation and a lower applied load were those with a working part length of 10 mm and an insertion depth of 2 mm, while those with lower deformation and a better load-bearing capacity were those with a working part length of 6 mm that were fully inserted into the bone support. Conclusions: The miniscrew design and insertion depth significantly affect biomechanical properties. It is advisable to maximize the insertion depth and minimize the distance between the support and the point of force application. The insertion angle did not prove to be a determining factor in the load.