Copper coatings are an important group of decorative-protective materials characterised by high corrosion resistance, excellent thermal and electrical conductivity, which lately gained more significance due to their antimicrobial activity. The main aim of the presented research was to electrodeposit homogenous copper coatings from the non-cyanide electrolyte solution in galvanostatic conditions on steel (1.4024) and nickel (Ni201) substrates, commercially used for surgical instruments. The effect of substrate finishes used in the production line, by shot peening with glass balls, corundum treatment and brushing on the coatings surface formation, was investigated. The substrates’ and coatings’ microstructural properties were analyzed by scanning and transmission electron microscopy, atomic force microscopy, and X-ray diffraction analysis. The current efficiency of the copper reduction on nickel and steel substrates was found to be above 95%. The copper layers adhere to both substrates, except those deposited on a brushed surface. Regardless of the substrate used, they have a nanocrystalline structure with an average crystallite size of 30 nm. Moreover, the coating surface morphology, which affects the nature of interaction with microorganisms, was effectively modified by the appropriate substrate finishing without changing the electrodeposition conditions.
Cardiovascular clamping procedures can cause tissue traumatization, leading to serious adverse events interrupting blood flow and causing life-threatening hemorrhage. The aim of the study is to evaluate the properties of 3D-printed, high-elasticity elastomeric materials—BioMed Flex 50A and 80A (Formlabs Inc., Sommerville, MA, USA)—in terms of their suitability for the fabrication of atraumatic inserts used for surgical clamping instruments. To show the importance of the elaboration of the new atraumatic materials, finite element simulations of blood vessel compression by a surgical tool were validated experimentally with porcine vessels, and histopathology assessed the tissue response. These results confirm that excessive clamping forces can cause vessel wall stratification and rupture. Specimens BioMed Flex 50A and 80A underwent surface, mechanical, and biological testing, including topography, wettability, acoustic microscopy for structural voids, cytotoxicity with human dermal fibroblasts, pro-inflammatory marker analysis, and bacterial biofilm assessment. The results of the testing of the 3D-printed BioMed Flex 50A and 80A materials show good potential for applications in safe atraumatic surgical instruments. Further research may include the possibilities to develop 3D-printed metamaterials with pressure adapting properties.