The goal of this work was to create a bioactive tissue-based scaffold using multi-disciplinary engineering materials and tissue engineering techniques. Materials & methods: Physical techniques such as direct laser interference lithography and proton radiation were selected as alternative methods of enzymatic and chemical decellularization to remove cells from a tissue without degradation of the extracellular matrix nor its protein structure. This study was an attempt to prepare a functional scaffold for cell culture from tissue of animal origin using new physical methods that have not been considered before. The work was carried out under full control of the histological and molecular analysis. Results & conclusions: The most important finding was that the physical methods used to obtain the decellularized tissue scaffold differed in the efficiency of cell removal from the tissue in favour of the laser method. Both the laser method and the proton method exhibited a destructive effect on tissue structure and the genetic material in cell nuclei. This effect was visible on histology images as blurred areas within the cell nucleus. The finite element 3D simulation of decellularization process of the three-layer tissue of animal origin sample reflected well the mechanical response of tissue described by hyperelastic material models and provided results comparable to the experimental ones.
Cardiovascular clamping procedures can cause tissue traumatization, leading to serious adverse events interrupting blood flow and causing life-threatening hemorrhage. The aim of the study is to evaluate the properties of 3D-printed, high-elasticity elastomeric materials—BioMed Flex 50A and 80A (Formlabs Inc., Sommerville, MA, USA)—in terms of their suitability for the fabrication of atraumatic inserts used for surgical clamping instruments. To show the importance of the elaboration of the new atraumatic materials, finite element simulations of blood vessel compression by a surgical tool were validated experimentally with porcine vessels, and histopathology assessed the tissue response. These results confirm that excessive clamping forces can cause vessel wall stratification and rupture. Specimens BioMed Flex 50A and 80A underwent surface, mechanical, and biological testing, including topography, wettability, acoustic microscopy for structural voids, cytotoxicity with human dermal fibroblasts, pro-inflammatory marker analysis, and bacterial biofilm assessment. The results of the testing of the 3D-printed BioMed Flex 50A and 80A materials show good potential for applications in safe atraumatic surgical instruments. Further research may include the possibilities to develop 3D-printed metamaterials with pressure adapting properties.
27 May 2025 in Archives of Civil and Mechanical Engineering
The aim of this work was to correlate biomechanical tests and simulations of implants dedicated to finger amputees. The implants were produced from Ti-6Al-4V (Ti64) alloy and ceramic ZrO2-Al2O3 (Alumina Toughened Zirconia 20, ATZ20). Research included finite element modeling, experimental simplified shear, tensile test, long-term cyclical tests of finger joint implant and their finite element models. Wear material collected during the experiment was evaluated for in vitro toxicity towards human fibroblast cells. Simulated fracture modes were verified by mechanical tests. During shear loading samples broke at ~ 55 N, whereas tensile break points were close to 110 N. Tested implant joints withstood one million cycle long-term test, however, partial wear of the anodized coating was noted. Wear debris from the joint was collected with a cellulose filter and analyzed for cytotoxic effects. Lactate dehydrogenase activity levels of cells incubated alongside collected wear material were only slightly higher than the control sample. Tested materials show promising potential for further research in terms of application.
Tantalum pentoxide (Ta2O5) coatings deposited via atomic layer deposition (ALD) have emerged as promising protective barriers for NiTi shape memory alloys in biomedical applications. This study investigates the influence of 800 ALD cycles on the structural, tribological, and electrochemical stability of NiTi substrates during long-term exposure to physiological environments. A conformal, amorphous Ta2O5 layer with a thickness of ∼65 nm was achieved, effectively sealing the substrate topography. Our findings reveal that while the coating initially maintains a hydrophilic character, prolonged incubation (60 days) in PBS solution triggers a transition to a hydrophobic state of 104 ± 3°, driven by the accumulation of Ca- and P-mineralized deposits. Tribological assessments demonstrate that the Ta2O5 overlayer enhances wear resistance and load-bearing capacity, despite localized microdelamination observed postexposure. Most notably, the ALD coating acts as a robust diffusion barrier, reducing the corrosion current density to 7.60 × 10–8 A/cm2 and maintaining a high polarization resistance even after 60 days of incubation. These results highlight the efficacy of Ta2O5 overlayers in providing long-term biostability and corrosion protection for NiTi-based implants in demanding physiological conditions.