Pan Zhuohong

Dr. Pan Zhuohong


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
WYWenxuan Yao
Wenxuan Yao
YLYong Liu
Yong Liu
DZDao Zhou
Dao Zhou
PZPan Zhuohong
Pan Zhuohong
MTMicah J. Till
Micah J. Till
YLYilu Liu
Yilu Liu
With the aid of global positioning system (GPS), synchronized measurement devices (SMDs) are increasingly deployed across power systems to monitor the status of electric grids by providing accurate measurement data along with unified time stamps. Unfortunately, GPS receivers tend to lose signal lock when certain uncontrollable and unpredictable factors arise. In order to investigate the presence of GPS signal loss (GSL) issues on measurement devices, analysis is performed on historical data from both phasor data concentrators and FNET/GridEye servers. Meanwhile, the impact of GSL on field measurement accuracy has not been previously explored in depth. Through analysis and experimental tests, this paper discovers angle drift caused by GSL, which consequently leads to the total vector error exceeding the IEEE standard C37.118.1-2011. Furthermore, a compensation method is proposed to rectify the angle drift and laboratory experiments demonstrate that the proposed method does effectively reduce angle drift and mitigate the impact of GSL in SMDs.

14 September 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
HLHesen Liu
Hesen Liu
LZLin Zhu
Lin Zhu
PZPan Zhuohong
Pan Zhuohong
FBFEIFEI BAI
FEIFEI BAI
YLYong Liu
Yong Liu
NBNavin Bhatt
Navin Bhatt
One of the main drawbacks of the existing oscillation damping controllers that are designed based on offline dynamic models is adaptivity to the power system operating condition. With the increasing availability of wide-area measurements and the rapid development of system identification techniques, it is possible to identify a measurement-based transfer function model online that can be used to tune the oscillation damping controller. Such a model could capture all dominant oscillation modes for adaptive and coordinated oscillation damping control. This paper describes a comprehensive approach to identify a low-order transfer function model of a power system using a multi-input multi-output (MIMO) autoregressive moving average exogenous (ARMAX) model. This methodology consists of five steps: 1) input selection; 2) output selection; 3) identification trigger; 4) model estimation; and 5) model validation. The proposed method is validated by using ambient data and ring-down data in the 16-machine 68-bus Northeast Power Coordinating Council system. The results demonstrate that the measurement-based model using MIMO ARMAX can capture all the dominant oscillation modes. Compared with the MIMO subspace state space model, the MIMO ARMAX model has equivalent accuracy but lower order and improved computational efficiency. The proposed model can be applied for adaptive and coordinated oscillation damping control.

18 July 2016 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
CHCan Huang
Can Huang
FLFangxing Li
Fangxing Li
DZDao Zhou
Dao Zhou
JGJiahui Guo
Jiahui Guo
PZPan Zhuohong
Pan Zhuohong
Yilu LiuYilu Liu
Yilu Liu
Synchrophasor systems, providing low-latency, high-precision, and time-synchronized measurements to enhance power grid performances, are deployed globally. However, the synchrophasor system as a physical network, involves communication constraints and data quality issues, which will impact or even disable certain synchrophasor applications. This work investigates the data quality issue for synchrophasor applications. In Part I, the standards of synchrophasor systems and the classifications and data quality requirements of synchrophasor applications are reviewed. Also, the actual events of synchronization signal accuracy, synchrophasor data loss, and latency are counted and analyzed. The review and statistics are expected to provide an overall picture of data accuracy, loss, and latency issues for synchrophasor applications.

31 May 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
GCGong Chen
Gong Chen
LLLei Lan
Lei Lan
PZPan Zhuohong
Pan Zhuohong
XWXishan Wen
Xishan Wen
YWYu Wang
Yu Wang
YWYang Wu
Yang Wu
Dynamic resistance measurement (DRM) was proved to be an important method for condition assessment of contact sets of SF 6 circuit breakers (CBs). The erosion of contact sets due to arc energy is a main factor that influences the electrical lifetime of the extinguishing chamber. In this study, a high‐voltage CB synthetic circuit was used to produce fault current for electrical erosion tests on the contact sets. The contact sets were close to the end of their service life after a series of erosion tests. DRMs with DC amperages of 0.5, 1.0, and 1.5 kA were conducted on the two tested breakers in the interval of each erosion test. Five essential diagnostic parameters were extracted from the contact resistance curves as a function of contact travel. The variation of these parameters during the whole erosion tests were investigated to find an effective condition assessment method for contact sets. From the power balance at the contact surface, the material erosion rate due to metal evaporation for each erosion test was calculated and in good agreement to the experimental results. Finally, the contact length and contact resistance were employed as diagnostic parameters for condition assessment of contact sets.

3 May 2017 in Energies
Verified
Journal Article
Open access
PDF file
Yu WangYu Wang
Yu Wang
XCXiaoyue Chen
Xiaoyue Chen
PZPan Zhuohong
Pan Zhuohong
HLHailiang Lu
Hailiang Lu
XWXishan Wen
Xishan Wen
TCTuteng Chen
Tuteng Chen
The outdoor ultra-high voltage (UHV) dry-type air-core smoothing reactors (DASR) of High Voltage Direct Current systems are equipped with a rain cover and an acoustic enclosure. To study the convective heat transfer between the DASR and the surrounding air, this paper presents a coupled model of the temperature and fluid field based on the structural features and cooling manner. The resistive losses of encapsulations calculated by finite element method (FEM) were used as heat sources in the thermal analysis. The steady fluid and thermal field of the 3-D reactor model were solved by the finite volume method (FVM), and the temperature distribution characteristics of the reactor were obtained. Subsequently, the axial and radial temperature distributions of encapsulation were investigated separately. Finally, an optical fiber temperature measurement scheme was used for an UHV DASR under natural convection conditions. Comparative analysis showed that the simulation results are in good agreement with the experimental data, which verifies the rationality and accuracy of the numerical calculation. These results can serve as a reference for the optimal design and maintenance of UHV DASRs.

24 February 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YWYu Wang
Yu Wang
PZPan Zhuohong
Pan Zhuohong
ZZZhipeng Zha
Zhipeng Zha
BTBo Tan
Bo Tan
XWXishan Wen
Xishan Wen
LLLei Lan
Lei Lan
This paper investigates the temperature rise of vertical/horizontal HVDC grounding electrodes by simulations and field tests. Based on a field-circuit coupling current distribution model and a 3D finite element model, a comprehensive methodology is proposed to analyze the transient temperature rise. Since soil resistivity varies with temperature around the electrodes, the temperature-dependent soil resistivity is tested, and then approximated by an empirical formula. Moreover, two practical tests are implemented to validate the simulation model. By ignoring the underground water fluctuations, the calculation results match test results nicely, which demonstrates that the terminal effect of the vertical electrode significantly affects the temperature distribution. But for a horizontal grounding electrode, the current distribution is more uniform than the vertical one. This study provides valuable references for design of HVDC grounding electrodes.