In this paper, we report on a novel sensor for the contactless monitoring of the respiration rate, made from multi-material fibers arranged in the form of spiral antenna (2.45 GHz central frequency). High flexibility of the used composite metal-glass-polymer fibers permits their integration into a cotton t-shirt without compromising comfort or restricting movement of the user. At the same time, change of the antenna geometry, due to the chest expansion and the displacement of the air volume in the lungs, is found to cause a significant shift of the antenna operational frequency, thus allowing respiration detection. In contrast with many current solutions, respiration is detected without attachment of the electrodes of any kind to the user’s body, neither direct contact of the fiber with the skin is required. Respiration patterns for two male volunteers were recorded with the help of a sensor prototype integrated into standard cotton t-shirt in sitting, standing, and lying scenarios. The typical measured frequency shift for the deep and shallow breathing was found to be in the range 120–200 MHz and 10–15 MHz, respectively. The same spiral fiber antenna is also shown to be suitable for short-range wireless communication, thus allowing respiration data transmission, for example, via the Bluetooth protocol, to mobile handheld devices.
We demonstrate the precision molecular spectroscopy of using a free-running, all-fiber dual electro-optic frequency comb system. Successive interferograms, acquired at a rate of , were phase-corrected in post-processing, averaged, and normalized to yield the complex transmission spectrum of several transitions within the band centered near . With spectral signal-to-noise ratios as high as 326:1 achieved in 2 ms of integration time, we report accurate measurements of transition intensities which will aid in the study of extreme astrophysical environments.
An approach for dual-comb spectroscopy using electro-optic (EO) phase modulation is reported. Maximum-length pseudo-random binary sequences allow for energy-efficient and flexible comb generation. Self-correction of interferograms is shown to remove relative comb drifts and improve mutual coherence, even for EO combs derived from the same laser source. Methane spectroscopy is reported over a spectral range, limited by the modulators’ bandwidth. The potential of a simple EO comb instrument is demonstrated to rapidly quantify atmospheric methane emissions with ppb precision over 1 km.
Optimizing the signal-to-noise ratio (SNR) is critical to achieve high sensitivities across broad spectral ranges in dual-comb interferometry. Sensitivity can be improved through time-averaging, but only at the cost of reduced temporal resolution. We show that it is instead possible to use high-bandwidth detection combined with frequency-domain averaging of multiple copies of the dual-comb beat note. By controlling the signal and noise stationarity properties, one can even reduce the fundamental shot noise contribution compared to the normal, single copy, dual-comb operation where integration time is matched to, or larger than the repetition period. In principle, the use of Na aliased frequency-domain copies will improve SNR by up to Na, or equivalently, reduce acquisition time by a factor of Na. We demonstrate dual-comb interferometry using Na = 5 aliases, achieving the predicted fivefold reduction in shot noise power density at low frequencies. Over the full spectrum, unaveraged relative intensity noise limits the SNR, but we measure a 1.65× fold improvement in detection of CO2, corresponding to a 2.7× reduction in acquisition time for a given precision.
Detector non-linearity is an important factor limiting the maximal power and hence the signal-to-noise ratio (SNR) in dual-comb interferometry. To increase the SNR without overwhelming averaging time, photodetector non-linearity must be properly handled for high input power. Detectors exhibiting nonlinear behavior can produce linear dual-comb interferograms if the area of the detector’s impulse response does not saturate and if the overlap between successive time-varying impulse responses is properly managed. Here, a high bandwidth non-amplified balanced photodetector is characterized in terms of its impulse response to high intensity short pulses to exemplify the conditions. With a 23.5 mW average power on each detector in a balanced pair, nonlinear spectral artifacts are at least 40 dB below the spectral baseline. Absorption lines of carbon dioxide are measured to reveal lines discrepancies smaller than 0.1% with HITRAN. A spectral shape independent formulation for the dual-comb figure of merit is proposed, reaching here 7.2 × 107 Hz1/2 limited by laser relative intensity noise, but corresponding to an ideal, shot-noise limited, figure of merit for an equivalent 0.85 mW average power per comb.
The impact of photodetector nonlinearity on dual-comb spectrometers is described and compared to that of Michelson-based Fourier transform spectrometers (FTS). The optical sampling occurring in the dual-comb approach, being the key difference with FTS, causes optical aliasing of the nonlinear spectral artifacts. Measured linear and nonlinear interferograms are presented to validate the model. Absorption lines of H13CN are provided to understand the impact of nonlinearity on spectroscopic measurements.