The temperature sensor is the core part of the temperature measurement instrument, and its performance directly determines the temperature measurement accuracy. Photonic crystal fiber (PCF) is a new type of temperature sensor with extremely high potential. In this paper, we propose a high-performance, structurally simple, liquid-filled PCF temperature sensor, which is based on a SMF-PCF-SMF (single mode fiber, SMF) sandwich structure. By adjusting the structural parameters of the the PCF, it is possible to obtain optical properties that are superior to those of ordinary optical fibers. This allows for more obvious responsive changes of the fiber transmission mode under small external temperature changes. By optimizing the basic structure parameters, a new PCF structure with a central air hole is designed, and its temperature sensitivity is -0.04696 nm/°C. When filling the air holes of PCFs with temperature-sensitive liquid materials, the response of the optical field against the temperature fluctuations can be effectively enhanced. The Chloroform solution is used to selectively infiltrate the resulting PCF owing to its large thermo-optical coefficient. After comparing various filling schemes, the calculation results show that the highest temperature sensitivity of -15.8 nm/°C is finally realized. The designed PCF sensor has a simple structure, high-temperature sensitivity, and good linearity showing great application potential.
The optical path length stability of the off-axis four-reflection telescope is one of the key technical indicators for the TianQin gravitational wave detection system. In the mHz observation band, the telescope must exhibit an optical path length stability of 0.4pm/Hz1/2. As a feasible solution, the optical path length stability measurement of the off-axis four-reflection telescope based on the Pound–Drever–Hall (PDH) technique imposes stringent requirements on the alignment of the off-axis resonant cavity (ORC). Taking the off-axis two-reflection prototype as the research object, we propose a Monte Carlo analysis-based method for ORC alignment precision analysis. By considering misalignment as an intermediate function, we establish a relationship between the coupling efficiency of the ORC and the wavefront aberration of the telescope. The research results show that by considering the combined effects of multiple misalignment couplings of the primary and secondary mirrors, when the detected telescope wavefront aberration is better than 0.068λ (λ=1064nm) with a probability of 98%, the ORC coupling efficiency can achieve greater than 40% with a probability of 97.13%, which can be used as the main reference indicator for system misalignment analysis. This method simplifies the alignment difficulty of the target under test and can provide alignment reference for subsequent resonant cavities with internal off-axis telescopes.
In space-based gravitational wave detection telescopes, backscattered light generated by the optical elements of the telescope interferes with the received signals, affecting interference measurements. Therefore, the analysis and suppression of backscattered light are crucial issues that must be considered in the telescope. In this paper, the results of a numerical model and simulation analysis are compared to analyze the stray light performance of two existing optical design schemes for telescopes. The contributions of backscattered light from the four mirrors have been determined, and the surface roughness indicators for optical elements meeting the stray light requirements have also been derived. This work lays the foundation for the manufacturing of prototype telescopes.
25 September 2023 in Classical and Quantum Gravity
To control the pointing accuracy of the telescope in the space gravitational wave detector at the nano-radian level, it is essential to design a flexure pivot with extremely low rotational moment nonlinearity during rotation. This study derives the theoretical equation of the nonlinear rotational moment of flexure pivot based on the beam bending strain energy equation and completes the design of ultra-low moment noise flexure pivot by integrating the structural form of conventional cross-spring flexure pivot. The nonlinear moment noise distribution in the frequency domain of three kinds of flexure pivots is then compared regarding TianQin’s circular high orbits. Then the relevant finite element simulation analysis will be performed for the flexure pivot structures, respectively, to ensure the accuracy of its rotational stiffness model and verify the correctness of nonlinear moment theory optimization through physical experiments. The results show that the optimized flexure pivot can effectively reduce the nonlinearity, and basically meet the nonlinear moment requirements in space gravitational wave detection.
3 February 2024 in Optics and Lasers in Engineering