About 40% of the US construction workforce experiences high-level fatigue, which leads to poor judgment, increased risk of injuries, a decrease in productivity, and a lower quality of work. Therefore, it is essential to monitor fatigue to reduce its adverse effects and prevent long-term health problems. However, since fatigue demonstrates itself in several complex processes, there is no single standard measurement method for fatigue detection. This study aims to develop a system for continuous workers’ fatigue monitoring by predicting the aerobic fatigue threshold (AFT) using forearm muscle activity and motion data. The proposed system consists of five modules: Data acquisition, activity recognition, oxygen uptake prediction, maximum aerobic capacity (MAC) estimation, and continuous AFT monitoring. The proposed system was evaluated on the participants performing fourteen scaffold-building activities. The results show that the AFT features have achieved a higher accuracy of 92.31% in assessing the workers’ fatigue level compared to heart rate (51.28%) and percentage heart rate reserve (50.43%) features. Moreover, the overall performance of the proposed system on unseen data using average two-min AFT features was 76.74%. The study validates the feasibility of using forearm muscle activity and motion data to workers’ fatigue levels continuously.
The workforce shortage is one of the significant problems in the construction industry. To overcome the challenges due to workforce shortage, various researchers have proposed wearable sensor-based systems in the area of construction safety and health. Although sensors provide rich and detailed information, not all sensors can be used for construction applications. This study evaluates the data quality and reliability of forearm electromyography (EMG) and inertial measurement unit (IMU) of armband sensors for construction activity classification. To achieve the proposed objective, the forearm EMG and IMU data collected from eight participants while performing construction activities such as screwing, wrenching, lifting, and carrying on two different days were used to analyze the data quality and reliability for activity recognition through seven different experiments. The results of these experiments show that the armband sensor data quality is comparable to the conventional EMG and IMU sensors with excellent relative and absolute reliability between trials for all the five activities. The activity classification results were highly reliable, with minimal change in classification accuracies for both the days. Moreover, the results conclude that the combined EMG and IMU models classify activities with higher accuracies compared to individual sensor models.
Real-time gait detection and pose estimation are critical for safety monitoring and prevention of work-related musculoskeletal disorders for construction workers. We present a single wearable inertial measurement unit (IMU)-based gait detection and pose estimation for human walking on flat and sloped surfaces. The gait detection algorithm is built on a recurrent neural network-based method and its outcome is then used in the full-body pose estimation. The detection scheme also predicts the terrain slope information in real-time. The pose estimation is obtained through learned motion manifold in latent space with the Gaussian process dynamic model. Extensive experiments of different walking patterns and speeds on the level and sloped surfaces are conducted to validate and demonstrate the design. The proposed algorithm can detect gait activities with 96% accuracy, the estimated human pose errors are within 8.30 degs, and the detection latency is within 18.6 ms using only a single IMU attached to a human shank.
The paper presents results of unconfined compression strength and seismic wave measurements during curing on a silty sand stabilized with three type of binders: geopolymers, lime and a mixture of lime and fly ash. Unconfined compression tests and indirect tensile tests were performed after 63 days of curing, and seismic wave measurements with ultrasonic transducers were measured during the curing period. The tests results show that specimens stabilized with geopolymer give much higher strength and stiffness results than the other binders. The specimens prepared with soil-lime-fly ash mixtures show a just slight increase in strength comparing to soil-lime specimens, conversely to what has been reported by other authors
1 December 2020 in Journal of Construction Engineering and Management
Thousands of construction workers suffer noise-induced hearing loss (NIHL) every year from excessive noise exposure on the job, which impairs the quality of their lives and increases the risk of injury. Properly wearing earplugs is very important onsite for worker hearing protection. However, the training provided in the current practice is minimal. Therefore, there is a need to develop an efficient and effective self-training method that can provide both accurate step-by-step earplug-wearing instructions and timely feedback through monitoring. With the development of artificial intelligence and wearable sensor technologies, the possibility of developing an advanced intelligent training method becomes plausible. Therefore, the objective of this paper is to develop a gesture recognition–based smart training assistant system that can automatically evaluate workers’ performance during their earplug-wearing self-training and provide timely feedback to rectify any mistakes. Through the system feasibility test and performance evaluation, the results show that the proposed system can achieve around 90% training accuracy and around 80% testing accuracy recognizing the classified forearm gestures of wearing earplugs for noise protection training using the developed artificial neural network (ANN) models for both hands. The proposed gesture recognition–based smart training assistant system will eventually help industries to improve the performance and safety of employees with low implementation costs.
14 October 2022 in International Journal of Industrial Ergonomics