Siyu Chen

Dr. Siyu Chen

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2016 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
JXJisheng Xiao
Jisheng Xiao
SCSiyu Chen
Siyu Chen
JYJi Yi
Ji Yi
HZHao F. Zhang
Hao F. Zhang
GAGuillermo A. Ameer
Guillermo A. Ameer

25 September 2015 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
JYJi Yi
Ji Yi
WLWenzhong Liu
Wenzhong Liu
SCSiyu Chen
Siyu Chen
VBVadim Backman
Vadim Backman
NSNader Sheibani
Nader Sheibani
HZHao F. Zhang
Hao F. Zhang
The lack of capability to quantify oxygen metabolism noninvasively impedes both fundamental investigation and clinical diagnosis of a wide spectrum of diseases including all the major blinding diseases such as age-related macular degeneration, diabetic retinopathy, and glaucoma. Using visible light optical coherence tomography (vis-OCT), we demonstrated accurate and robust measurement of retinal oxygen metabolic rate (rMRO2) noninvasively in rat eyes. We continuously monitored the regulatory response of oxygen consumption to a progressive hypoxic challenge. We found that both oxygen delivery, and rMRO2 increased from the highly regulated retinal circulation (RC) under hypoxia, by 0.28 ± 0.08 µL min−1 (p < 0.001), and 0.20 ± 0.04 µL min−1 (p < 0.001) per 100 mmHg systemic pO2 reduction, respectively. The increased oxygen extraction compensated for the deficient oxygen supply from the poorly regulated choroidal circulation. Results from an oxygen diffusion model based on previous oxygen electrode measurements corroborated our in vivo observations. We believe that vis-OCT has the potential to reveal the fundamental role of oxygen metabolism in various retinal diseases.

1 September 2016 in Journal of Controlled Release
Verified
Journal Article
Closed access
YZYunxiao Zhu
Yunxiao Zhu
RHRyan Hoshi
Ryan Hoshi
SCSiyu Chen
Siyu Chen
JYJi Yi
Ji Yi
CDChongwen Duan
Chongwen Duan
GAGuillermo A. Ameer
Guillermo A. Ameer

16 February 2015 in Optica
Verified
Journal Article
Open access
PDF file
BDBiqin Dong
Biqin Dong
HLHao Li
Hao Li
ZZZhen Zhang
Zhen Zhang
KZKevin Zhang
Kevin Zhang
SCSiyu Chen
Siyu Chen
HZHao F. Zhang
Hao F. Zhang
Photoacoustic microscopy (PAM) is an attractive imaging tool that complements established optical microscopic modalities by providing additional molecular specificities through imaging optical absorption contrast. While the development of optical resolution photoacoustic microscopy (ORPAM) offers high lateral resolution, the acoustically determined axial resolution is limited due to the constraint in ultrasonic detection bandwidth. ORPAM with isometric spatial resolution along both axial and lateral directions is yet to be developed. Although recently developed sophisticated optical illumination and reconstruction methods offer improved axial resolution in ORPAM, the image acquisition procedures are rather complicated, limiting their capabilities for high-speed imaging and being easily integrated with established optical microscopic modalities. Here we report an isometric ORPAM based on an optically transparent micro-ring resonator ultrasonic detector and a commercial inverted microscope platform. Owing to the superior spatial resolution and the ease of integrating our ORPAM with established microscopic modalities, single-cell imaging with extrinsic fluorescence staining, intrinsic autofluorescence, and optical absorption can be achieved simultaneously. This technique holds promise to greatly improve the accessibility of PAM to broader biomedical researchers.

21 July 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BDBiqin Dong
Biqin Dong
SCSiyu Chen
Siyu Chen
ZZZhen Zhang
Zhen Zhang
CSCheng Sun
Cheng Sun
HZHao F. Zhang
Hao F. Zhang
We designed an all-optical photoacoustic (PA) probe for endoscopic applications by employing an optically transparent, coverslip-type, polymeric microring resonator ultrasonic sensor. We experimentally quantified the axial, tangential, and radial resolutions and angular sensitive stability of this probe. Using this probe, we achieved volumetric imaging of several phantoms. Our all-optical probe design offers clear benefit in integrating PA endoscope with other optical endoscopic imaging modalities to facilitate the transformation from bench to bedside.

1 September 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
JYJi Yi
Ji Yi
SCSiyu Chen
Siyu Chen
XSXiao Shu
Xiao Shu
AFAmani A. Fawzi
Amani A. Fawzi
HZHao F. Zhang
Hao F. Zhang
We achieved human retinal imaging using visible-light optical coherence tomography (vis-OCT) guided by an integrated scanning laser ophthalmoscopy (SLO). We adapted a spectral domain OCT configuration and used a supercontinuum laser as the illumating source. The center wavelength was 564 nm and the bandwidth was 115 nm, which provided a 0.97 µm axial resolution measured in air. We characterized the sensitivity to be 86 dB with 226 µW incidence power on the pupil. We also integrated an SLO that shared the same optical path of the vis-OCT sample arm for alignment purposes. We demonstrated the retinal imaging from both systems centered at the fovea and optic nerve head with 20° × 20° and 10° × 10° field of view. We observed similar anatomical structures in vis-OCT and NIR-OCT. The contrast appeared different from vis-OCT to NIR-OCT, including slightly weaker signal from intra-retinal layers, and increased visibility and contrast of anatomical layers in the outer retina.