Kei Kamada

Dr. Kei Kamada

orcid

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Optical Materials
Verified
Journal Article
Closed access
Yuui YokotaYuui Yokota
Yuui Yokota
SKShunsuke Kurosawa
Shunsuke Kurosawa
YSYasuhiro Shoji
Yasuhiro Shoji
YOYuji Ohashi
Yuji Ohashi
KKKei Kamada
Kei Kamada
AYAkira Yoshikawa
Akira Yoshikawa

8 June 2023 in Crystals
Verified
Journal Article
Open access
PDF file
KKKei Kamada
Kei Kamada
RSRei Sasaki
Rei Sasaki
TTTaketoshi Tomida
Taketoshi Tomida
ITIsao Takahashi
Isao Takahashi
MYMasao Yoshino
Masao Yoshino
AYAkira Yoshikawa
Akira Yoshikawa
β-Ga2O3 is a well-known semiconductor material for power devices and other applications. Recently, β-Ga2O3 has also been reported as a scintillator material with a light yield of approximately 8400 ph./MeV, scintillation decay time of <1 μs, and density of 6.44 g/cm3. In this study, 45 cm diameter β-Ga2O3 single crystals were prepared via oxide crystal growth using the cold crucible (OCCC) method under various oxygen partial pressures. In the OCCC method, as in the cold crucible method, a high frequency is applied directly to the oxide materials, which are heated and melted, and the melt is held by the outermost solid material itself that is cooled by water using a copper hearth. In the OCCC method, crystal growth is performed while rotating the seed crystal, as in the Czochralski method, to increase the crystal diameter. The optical properties and radiation responses of the crystals grown under various oxygen partial pressures were evaluated.

1 April 2018 in Journal of Crystal Growth
Verified
Journal Article
Closed access
RMRikito Murakami
Rikito Murakami
KKKei Kamada
Kei Kamada
YSYasuhiro Shoji
Yasuhiro Shoji
Yuui YokotaYuui Yokota
Yuui Yokota
MYMasao Yoshino
Masao Yoshino
AYAkira Yoshikawa
Akira Yoshikawa

20 October 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
EYEiji Yoshida
Eiji Yoshida
FOFujino Obata
Fujino Obata
KKKei Kamada
Kei Kamada
TYTaiga Yamaya
Taiga Yamaya
To improve positron emission tomography (PET) image quality, depth-of-interaction (DOI) information and timeof-flight (TOF) information are key technologies. In this work, we developed the DOI-TOF detector based on our original singleended readout scheme with the continuous layered gadolinium fine aluminum garnet (GFAG) array. The size of each GFAG crystal is 1.45×1.45×20 mm3. The multi-pixel photon counter (MPPC) used as a photo-sensor has a surface area of 3.0×3.0 mm2. One pair of crystals coupled with a partial optical window is arranged across two MPPCs. Boundaries without the partial optical window are covered with optical reflectors. Each pair is coupled with paired MPPCs of different patterns. Crystal identification is obtained from paired MPPCs of different patterns and output rates. By limiting the spread of scintillation light, the proposed DOI detector based on the local centroid calculation was expected to improve crystal response including the edge. For performance comparison, we prepared three discrete layers of the GFAG array with the same total thickness. For the continuous layer, the DOI resolution, the energy resolution and the timing resolution of the pair of detectors are 4.7 mm, 14% and 402 ps, respectively. Their respective values are 29%, 20% and 33% better than those with the three discrete layers.

24 January 2014 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
KKKei Kamada
Kei Kamada
KSKenji Shimazoe
Kenji Shimazoe
SIShigeki Ito
Shigeki Ito
MYMasao Yoshino
Masao Yoshino
TETakanori Endo
Takanori Endo
AYAkira Yoshikawa
Akira Yoshikawa
A novel digital PET scanner based on Time over Threshold method is developed. The positron emission tomography (PET) is composed of 144channel Ce:Gd3Al2Ga3O12 (GAGG)-Avaranche photodiode (APD) detector arrays individually coupled with custom designed Time over Threshold (ToT) application-specific integrated circuit (ASIC) to realize the high count rate and good spatial resolution. Such an imaging system provides a simple front-end circuit and flexible digital signal processing like multiplexing such as a pulse train method. The measured energy resolution of the detector system was 6.7% for the 511 keV peak, and 4.25 ns time resolution was measured with a single detector module. The measured spatial resolution for a point source was 1.37 mm FWHM for our initial data with a columnar 22Na source.

1 February 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MKMasaaki Kaburagi
Masaaki Kaburagi
KSKenji Shimazoe
Kenji Shimazoe
MKMasahiro Kato
Masahiro Kato
TKTadahiro Kurosawa
Tadahiro Kurosawa
KKKei Kamada
Kei Kamada
TTTatsuo Torii
Tatsuo Torii